Harman Kardon AVR 260 (serv.man2) EMC - CB Certificate ▷ View online
Reference No. : 54120802A Page 15
◀ Anam EMC Test Laboratory ▶
VIDEO VIDEO 1,
VIDEO 2 IN/OUT
172.03
50.3 40.3 *
*
VIDEO VIDEO 3
MONITOR OUT
172.03
50.3 40.3 *
*
PREOUT FL/FR
270.34
53.9 43.9 28.5 27.3
PREOUT SL/SR
270.34
53.9 43.9 28.8 27.4
PREOUT C/SW
270.34
53.9 43.9 27.3 26.1
PREOUT SBL/SBR
270.34
53.9 43.9 28.3 27.1
ZONE 2
172.03
50.3 40.3 *
*
REMOTE IN
172.03
50.3 40.3 *
*
REMOTE OUT
172.03
50.3 40.3 *
*
AUX 3
172.03
50.3 40.3 *
*
SPEAKER R
172.03
50.3 40.3 28.8 25.7
SPEAKER L
172.03
50.3 40.3 29.2 25.9
SPEAKER SBR
172.03
50.3 40.3 28.5 25.3
SPEAKER SBL
172.03
50.3 40.3 28.2 25.1
SPEAKER SR
172.03
50.3 40.3 27.8 25.3
SPEAKER SL
172.03
50.3 40.3 27.4 25.1
SPEAKER C
172.03
50.3 40.3 28.3 25.5
AC POWER CORD
184.34
50.7 40.7 *
*
*: less than 25 ㏈㎺
Limit
according
to
EN55013:2001+A2(2006)
Note:1) The spectrum was checked from 30 to 300 ㎒.
2) The cable (6.0m length) loss is included in a correction factor.
3) Detector function of the measuring instrument:
QP: Quasi-peak, AV: Average
4) QP line: Limit (㏈㎺) = Frequency (㎒) ×0.037 + 43.9
AV line: Limit (㏈㎺) = Frequency (㎒) ×0.037 + 33.9
5) *: Less than 25 ㏈㎺
For the measurement data, see Annex B (48 Copies).
Reference No. : 54120802A Page 16
◀ Anam EMC Test Laboratory ▶
9. HARMONICS
9.1. Operating environment
Temperature
: 16℃
Relative humidity : 55%
9.2. Test set-up and procedure
Harmonics of the fundamental current were measured up to 2 ㎑ using a
universal power analyzer. The measurement was carried out under steady
conditions and using averaging.
The Class of this equipment is “Class A” by clause 5 of EN61000-3-2(2000)
+A2(2005).
The measurement was performed with the Test software for Windows
The input signal and load conditions were set as given in clause 4.2.4 of
IEC 60065.
The input signal and load conditions were set as given in clause 4.2.4 of
IEC 60065.
9.3. Test instrumentation
Equipment
Mfr.
Type No.
Serial No.
R. C. Oscillator
Kenwood
AG-203A
3090241
Universal power analyzer Voltech
PM6000
100006700178
Programmable controller
Pacific
360AMXT/UPC32
151
Magnetics module
Pacific
134310
334
9.4. Test result
The equipment does comply with the requirements.
For the measurement data, see Annex C (3 Copies).
For the measurement data, see Annex C (3 Copies).
Reference No. : 54120802A Page 17
◀ Anam EMC Test Laboratory ▶
10. VOLTAGE FLUCTUATIONS-FLICKER
10.1. Operating environment
Temperature
: 16℃
Relative humidity : 55%
10.2. Test set-up and procedure
The open circuit test voltage was the rated voltage of the EUT.
The reference impedance was a conventional impedance being used to calculate
or measure the disturbance caused by an appliance.
or measure the disturbance caused by an appliance.
The measurement was performed with the Test software for Windows
10.3. Test instrumentation
Equipment
Mfr.
Type No.
Serial No.
R. C. Oscillator
Kenwood
AG-203A
3090241
Reference impedance
Voltech
IEC Standard 555
IB16/0725
Universal power analyzer Voltech
PM6000
100006700178
Programmable controller
Pacific
360AMXT/UPC32
151
Magnetics module
Pacific
134310
334
10.4. Test result
The equipment does comply with the requirements.
For the measurement data, see Annex D (1 Copies).
Reference No. : 54120802A Page 18
◀ Anam EMC Test Laboratory ▶
11. Photograph of the EUT
11.1 Front of the EUT
11.2 Rear of the Product
Click on the first or last page to see other AVR 260 (serv.man2) service manuals if exist.