Harman Kardon AVR 165 (serv.man5) EMC - CB Certificate ▷ View online
Page 7 of 10
Report No.: 162890
ATTACHMENT 3
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
Bibliogra
phy in
EN
60065:20
02
phy in
EN
60065:20
02
Replace the paragraph related to prEN 50332-2 by:
EN 50332-2:2003, Sound system equipment: Headphones and earphones
associated with portable audio equipment - Maximum sound pressure level
measurement methodology and limit considerations - Part 2: Matching of sets with
headphones if either or both are offered separately EN 60065:2002/A1:2006 - 4 -
EN 50332-2:2003, Sound system equipment: Headphones and earphones
associated with portable audio equipment - Maximum sound pressure level
measurement methodology and limit considerations - Part 2: Matching of sets with
headphones if either or both are offered separately EN 60065:2002/A1:2006 - 4 -
N/A
Bibliogra
phy in IEC
60065:200
1/A1:2005
phy in IEC
60065:200
1/A1:2005
Add the following notes for the standards indicated:
IEC 60598-2-9 NOTE Harmonized as EN 60598-2-9:1989 + A1:1994
(not modified).
IEC 60598-2-17 NOTE Harmonized as EN 60598-2-17:1989 + A2:1991
(not modified).
IEC 60598-2-9 NOTE Harmonized as EN 60598-2-9:1989 + A1:1994
(not modified).
IEC 60598-2-17 NOTE Harmonized as EN 60598-2-17:1989 + A2:1991
(not modified).
N/A
ZB
ANNEX ZB TO EN 60065, SPECIAL NATIONAL CONDITIONS (EN)
2.6.1
DK: The following is added:
Certain types of CLASS I apparatus, see 15.1.1,
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
Justification: Heavy Current Regulations, Section
107.
Certain types of CLASS I apparatus, see 15.1.1,
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
Justification: Heavy Current Regulations, Section
107.
Class II apparatus
N/A
13.3.1
NO: To the second paragraph the following is
added:
In Norway, due to the IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230 V in case of a single earth fault.
added:
In Norway, due to the IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230 V in case of a single earth fault.
Justification: Based on a use in Norway of an IT
power distribution system where the neutral is not
provided.
power distribution system where the neutral is not
provided.
Noted
N/A
Page 8 of 10
Report No.: 162890
ATTACHMENT 3
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
15.1.1
DK: To the first paragraph the following is added:
In Denmark, supply cords of single phase
appliances having a rated current not exceeding 13
A shall be provided with a plug according to the
Heavy Current Regulations Section 107-2-D1.
Appliances of CLASS I provided with socket-outlets
with earth contact or which are intended to be used
in locations where protection against indirect
contact is required according to the wiring rules
shall be provided with a plug in accordance with
the Heavy Current Regulations Section 107-2-D1
standard sheet DK 2-1a.
To the second paragraph the following is added:
Socket outlets intended for provided power to
CLASS II apparatus with a rated current of 2.5 A
shall have the following dimensions:
In Denmark, supply cords of single phase
appliances having a rated current not exceeding 13
A shall be provided with a plug according to the
Heavy Current Regulations Section 107-2-D1.
Appliances of CLASS I provided with socket-outlets
with earth contact or which are intended to be used
in locations where protection against indirect
contact is required according to the wiring rules
shall be provided with a plug in accordance with
the Heavy Current Regulations Section 107-2-D1
standard sheet DK 2-1a.
To the second paragraph the following is added:
Socket outlets intended for provided power to
CLASS II apparatus with a rated current of 2.5 A
shall have the following dimensions:
Dimensions in mm
Other dimensions shall be in compliance with the
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DKA 1-3 for portable socket-
outlets. Shutters are not required.
To the third paragraph the following is added:
Mains socket-outlets with earthing contact shall be
in compliance with the Heavy Current Regulations,
Section 107-2-D1, Standard Sheet DK 1-3a, DK 1-
5a or DK 1-7a.
Justification:
Heavy Current Regulations, Section 107
Other dimensions shall be in compliance with the
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DKA 1-3 for portable socket-
outlets. Shutters are not required.
To the third paragraph the following is added:
Mains socket-outlets with earthing contact shall be
in compliance with the Heavy Current Regulations,
Section 107-2-D1, Standard Sheet DK 1-3a, DK 1-
5a or DK 1-7a.
Justification:
Heavy Current Regulations, Section 107
No socket-outlets
N/A
15.1.1
IE: Apparatus which is fitted with a flexible cable or
cord shall be provided with a 13 A plug in
accordance with Statutory Instrument 525:97, “13 A
Plugs and Conversion Adapters for Domestic Use
Regulations:1997.
cord shall be provided with a 13 A plug in
accordance with Statutory Instrument 525:97, “13 A
Plugs and Conversion Adapters for Domestic Use
Regulations:1997.
Justification: SI 525: 1997
When marketing in Ireland,
the apparatus must be supplied
with a cord and plug acceptable
in Ireland.
the apparatus must be supplied
with a cord and plug acceptable
in Ireland.
N/A
Page 9 of 10
Report No.: 162890
ATTACHMENT 3
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
15.1.1
Cont.
NO: Mains socket-outlets mounted on CLASS II
apparatus shall comply with the specifications
given in CEE Publ. 7 as fas as a Applicable, with
the following amendments:
§ 8 Dimensions
a 2.5 A 250 V two-pole socket-outlets for electronic
apparatus shall comply with the enclosed Standard
Sheet I.
apparatus shall comply with the specifications
given in CEE Publ. 7 as fas as a Applicable, with
the following amendments:
§ 8 Dimensions
a 2.5 A 250 V two-pole socket-outlets for electronic
apparatus shall comply with the enclosed Standard
Sheet I.
§ 24 Mechanical strength
A 2,5 A 250 V socket-outlets for CLASS II
electronic apparatus are tested as specified in
12.1.3 of EN 60065. Also the protecting rim shall
be tested
Justification: Act of 24 May 1929 relating to
supervision of electrical installation (TEA 1929/FEL
1998).
A 2,5 A 250 V socket-outlets for CLASS II
electronic apparatus are tested as specified in
12.1.3 of EN 60065. Also the protecting rim shall
be tested
Justification: Act of 24 May 1929 relating to
supervision of electrical installation (TEA 1929/FEL
1998).
No socket-outlets
N/A
15.1.1
UK: Apparatus which is fitted with a flexible cable
or cord and is designed to be connected to a mains
socket conforming to BS 1363 by means of that
flexible cable or cord and plug shall be fitted with
a ”standard plug” in accordance with Statutory
Instrument 1768: 1994: The Plugs and Sockets etc.
(Safety) Regulations 1994, unless exempted by
those Regulations.
NOTE ”Standard plug” is defined in SI 1768:1994
and essentially means an approved plug
conforming to BS 1363 or an approved conversion
plug.
Justification: SI 1768: 1994
or cord and is designed to be connected to a mains
socket conforming to BS 1363 by means of that
flexible cable or cord and plug shall be fitted with
a ”standard plug” in accordance with Statutory
Instrument 1768: 1994: The Plugs and Sockets etc.
(Safety) Regulations 1994, unless exempted by
those Regulations.
NOTE ”Standard plug” is defined in SI 1768:1994
and essentially means an approved plug
conforming to BS 1363 or an approved conversion
plug.
Justification: SI 1768: 1994
See appended table,
List of critical components.
List of critical components.
P
Page 10 of 10
Report No.: 162890
ATTACHMENT 3
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
J.2
NO: After Table J.1 the following is added:
In Norway, due to the IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230 V in case of a single earth fault.
Justification: Based on a use in Norway of an IT
power distribution system where the neutral is not
provided.
In Norway, due to the IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230 V in case of a single earth fault.
Justification: Based on a use in Norway of an IT
power distribution system where the neutral is not
provided.
Noted.
N/A
ZC
ANNEX ZC TO EN 60065, A-DEVIATIONS (EN)
5.1
IT: Additional markings on the outside of the TV
receiver in Italian language
receiver in Italian language
Not a TV product.
N/A
IT:User instructions in Italian language including a
conformity declaration
conformity declaration
N/A
IT: Certification number on the back cover
N/A
6.1
DE: The following requirement applies:
For the operation of any cathode ray tube intended
for the display of visual images operating at an
acceleration voltage exceeding 40 kV,
authorization is required, or application of type
approval (Bauartzulassung) and marking.
for the display of visual images operating at an
acceleration voltage exceeding 40 kV,
authorization is required, or application of type
approval (Bauartzulassung) and marking.
Justification: German ministerial decree against
ionizing radiation (Röntgenverordnung), in force
since 2002-07-01, implementing the European
Directive 96/29/EURATOM.
ionizing radiation (Röntgenverordnung), in force
since 2002-07-01, implementing the European
Directive 96/29/EURATOM.
NOTE Contact address:
Physikalisch-Technische Bundesanstalt,
Bundesallee 100, D-38116 Braunschweig, Tel.:
Int+49-531-592-6320, Internet: http://www.ptb.de
Bundesallee 100, D-38116 Braunschweig, Tel.:
Int+49-531-592-6320, Internet: http://www.ptb.de
No CRT used in the
equipment.
equipment.
N/A
14
SE: Switches containing mercury such as
thermostats, relays and level controllers are not
allowed.
thermostats, relays and level controllers are not
allowed.
Justification: Ordinance (1990:944) on Prohibition
in Connection with handling. Importation and
exportation of Chemical Products (Certain Cases)
in Connection with handling. Importation and
exportation of Chemical Products (Certain Cases)
Considered.
P