Page 37 of 44 
 
Report No.: 162890 
 
 
TRF No. IEC60065J 
 
 
 
11.2 
TABLE: summary of fault condition tests 
 
Voltage (V) 0,9 or 1,1 times rated voltage  ............. :  198V or 264V 
— 
 
Ambient temperature (
o
C)  ...................................... :  21 
o
C - 25 
o
— 
Monitored point: 
Under fault conditions specified below 
dT (K) 
Permitted 
dT (K) 
1. *),
***)
, D105 (A to C), SC, 30 min;  
FL display off immediately, FI stabilised at 0.81A, F110 opened, No hazard. 
N/A 
N/A 
2. *),***), C135, SC, FI: 0.36A, 30 min; 
Signal output and FL display off immediately, FI stabilised at 0.36A, 
F110 and F111 opened, No hazard. 
N/A 
N/A 
3. *),***), D124 (A to C), SC, 30 min;  
FL display off immediately, FI stabilised at 0.81A, F111 opened, No hazard. 
N/A 
N/A 
4. *),***), D114 (A to C), SC, 30 min; 
Signal output off immediately, FI stabilised at 0.39A, 
R104, R105 damaged, No hazard. 
N/A 
N/A 
5. *),***), D117 (A to C), SC, 30 min;  
Normal operation, FI stabilised at 0.81A, R105 damaged, No hazard. 
N/A 
N/A 
6. *),***), C107, SC, 30 min;  
Normal operation, FI stabilised at 0.81A, R104 damaged, No hazard. 
N/A 
N/A 
7. **),****), C108, SC, 30 min;  
Normal operation, FI stabilised at 0.76A, R105 damaged, No hazard. 
N/A 
N/A 
8. *),***), C105, SC, 30 min; 
FL display off immediately, FI stabilised at 0.81A, F110 opened, No hazard. 
N/A 
N/A 
9. **),****), C104, SC, 30 min;  
Normal operation, FI stabilised at 0.76A, F111 opened, No hazard. 
N/A 
N/A 
10. *), ***), D991 (AC to +), SC, 10 min; 
F901 opened immediately, FI stabilised at 0.006A, No hazard. 
N/A 
N/A 
11. **), ****), D991 (AC to -), SC, 10 min; 
Unit shut down immediately, FI stabilised at 0.003A, No hazard. 
N/A 
N/A 
12. *),***), C915, SC, 10 min; 
Unit shut down immediately, FI stabilised at 0.006A, No hazard. 
N/A 
N/A 
13. **),****), C916, SC, 10 min; 
Unit shut down immediately, FI stabilised at 0.003A, No hazard. 
N/A 
N/A 
14. *),***), Q658 (B to C), SC, 10 min; 
Unit shut down immediately, FI stabilised at 0.006A, Q652, Q658, Q857 
R647 and R657 damaged, No hazard. 
N/A 
N/A 
*)  Tested voltage 264V                
**)  Tested voltage 198V 
Tested at,         ***) HIGH mode,        ****) LOW mode            of the main transformer S1A or S1B output.
 
Note- SC: Short-circuit, NCD: No component damage, FI: Fault Input Current 
 
 
 
Page 38 of 44 
 
Report No.: 162890 
 
 
TRF No. IEC60065J 
 
 
 
Monitored point: 
Under fault conditions specified below- continued 
dT (K) 
Permitted 
dT (K) 
15. *),***), Q658 (C to E), SC, 10 min; 
Unit shut down immediately, FI stabilised at 0.006A, Q652, R657 damaged, 
 No hazard. 
N/A 
N/A 
16. **),****), Q652 (B to C), SC, 10 min; 
Unit shut down immediately, FI stabilised at 0.003A, NCD No hazard. 
N/A 
N/A 
17. **),****), Q658 (C to E), SC, 10 min; 
Unit shut down immediately, FI stabilised at 0.003A, Q652, Q658, Q857 
R647 and R657 damaged, No hazard. 
N/A 
N/A 
18. *),***), D956 (A to C), SC, FI: 1.09A, 4 hr; 
Unit shut down after 1hr, FI stabilised at 0.35A, 
Sub transformer primary winding heated up to 94.1K and stabilised. 
Dielectric strength test O.K. No hazard. 
Sub transf. 
94.1 
Sub transf. 
150 
19. *),***), D901 (A to C), SC, FI: 1.09A, 4 hr; 
Unit shut down after 1hr, FI stabilised at 0.35A, 
Sub transformer primary winding heated up to 97.4K and stabilised. 
Dielectric strength test O.K. No hazard. 
Sub transf. 
97.4 
Sub transf. 
150 
20. *),***), C906, SC, 4 hr; 
Unit shut down immediately, FI stabilised at 0.02A, 
Sub transformer primary winding heated up to 98.3K and stabilised. 
Dielectric strength test O.K. No hazard. 
Sub transf. 
98.3 
Sub transf. 
150 
21. *),***), Speaker output (FR- ch.), SC, FI: 1.08A, 10 min; 
Unit shut down after 3sec, FI stabilised at 0,006A, Q803, Q804, Q856, 
R810 and R818 damaged, No hazard. 
N/A 
N/A 
22. *),***), USB output, SC, 30 min; 
Signal output and FL display off immediately, FI stabilised at 0,45A, 
 NCD, No hazard. 
N/A 
N/A 
23.*),***), Pmax operated (Maximum non-clipped output signal);  
Main transformer primary winding heated up to 134.2K and  
thermal fuse opened after 38 min. FI stabilised at 0.013A. 
Dielectric strength test O.K. No hazard. 
Main tranf. 
134.2 
Main tranf. 
150 
24. *), Cover opening, Blocked, 4hr;  
Normal operation. FI stabilised at 0.81A.  
NCD, Dielectric strength test O.K. No hazard. 
See next page  
for measured highest  
temperature. 
*)  Tested voltage 264V               
 **)  Tested voltage 198V 
Tested at,         ***) HIGH mode,        ****) LOW mode           of the main transformer S1A or S1B output.
 
Note- SC: Short-circuit, NCD: No component damage, FI: Fault Input Current 
 
 
 
 
 
Page 39 of 44 
 
Report No.: 162890 
 
 
TRF No. IEC60065J 
 
 
 
11.2 
TABLE: temperature rise measurements 
Monitored point: 
 
 
dT (K) at  
264V / 50Hz 
Permitted  
dT (K) 
Main transformer core 
 
 
66.5 
150 
Sub transformer core 
 
 
41.2 
150 
PWB near D991 
 
 
64.9 
110 
PWB near D105 
 
 
39.9 
110 
PWB near Q803 
 
 
54.0 
110 
PWB near IC91 
 
 
53.9 
110 
CN91 AC connector 
 
 
32.3 
CN92 AC connector 
 
 
31.2 
Enclosure top above main transformer 
 
 
36.5 
65 
Enclosure top above main heat-sink 
 
 
42.9 
65 
Inlet body 
 
 
17.5 
65 
Mains switch (rear side) 
 
 
13.7 
65 
Stand-by button (non-metallic) 
 
 
10.6 
65 
Front panel (non-metallic) 
 
 
13.7 
65 
Ambient 
 
 
21.6°C 
 
 
 
 
 
 
 
Winding temperature rise measurements 
264V / 50Hz 
— 
 
Ambient temperature t1 (
o
C) Main / Sub : 
19.8 / 22.0 
— 
 
Ambient temperature t2 (
o
C) : 
21.6 / 21.6 
— 
Temperature rise dT of winding: 
R
1
 
(Ω) 
R
2
 
(Ω) 
dT (K) 
Permitted d
T (K) 
Insulation 
class 
Main transf. primary winding  
6.143 
7.992 
74.7 
150 
Sub transf. primary winding  
3788 
4539 
51.3 
150 
 
 
 
 
 
 
 
 
 
 
Page 40 of 44 
 
Report No.: 162890 
 
 
TRF No. IEC60065J 
 
 
 
13 
TABLES: clearances and creepage distances 
Rated supply voltage: 
240 V 
Pollution degree: 
Material Group: 
IIIb 
2 N force on internal parts applied: 
Yes 
30 N force on outside of conductive enclosure applied: 
Yes 
Type of  
Insulation 
Position/ Location 
Operating Voltage  
Clearance (mm) 
Creepage (mm) 
Com
m. 
V peak 
V rms 
Min 
Actual 
Min 
Actual 
Circuits conductively connected to the mains (use Tables 8 and 11): see note below. 
Basic 
Live 
Neutral 
340 
240 
2.0 
3.8 
2.5 
3.8 
1) 
Reinforce 
Primary  
Secondary 
340 
240 
4.0 
6.2 
5.0 
6.2 
2) 
Reinforce 
Primary 
Secondary 
340 
240 
4.0 
6.5 
5.0 
6.5 
3) 
Reinforce 
Primary 
Chassis 
340 
240 
4.0 
5.8 
5.0 
>6.5 
4) 
 
 
 
 
 
 
 
 
 
 
Comments: 
1)  Measured on pcb before mains fuse. 
2)   Measured on main pcb from primary trace for F901 to near secondary trace for D643. 
3)  Measured on main pcb from pr. trace for CN92 to near sec. trace connected to metal  
 
chassis. 
4)  Measured between primary solder pin and near metal chassis (bottom). 
 
 
 
 