Harman Kardon AVR 165 (serv.man5) EMC - CB Certificate ▷ View online
Page 17 of 44
Report No.: 162890
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
13
Clearances and creepage distances
13.1
Clearances in accordance with 13.3
See 13.3
P
Creepage distances in accordance with 13.4
See 13.4
P
13.2
Determination of operating voltage
Conventional transformer used.
Upper rated supply voltage
(240V) applied in determining
the operating voltage
Upper rated supply voltage
(240V) applied in determining
the operating voltage
P
13.3
Clearances
2N for internal parts and
30N for enclosure are
considered when determining
clearances.
30N for enclosure are
considered when determining
clearances.
P
13.3.1
General
Considered
P
13.3.2
Circuits conductively connected to the mains
comply with table 8 and, where applicable, table 9..:
comply with table 8 and, where applicable, table 9..:
(see appended table 13)
P
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
No hazardous secondary
voltages
voltages
N/A
13.3.4
Measurement of transient voltages
No measurement of
transient voltages
transient voltages
N/A
13.4
Creepage distances
CTI > 100
(see appended table 13)
(see appended table 13)
P
Creepage distances greater than table 11 minimum
values
values
Not applicable
N/A
13.5
Printed boards
Refer to below
N/A
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
No such PCB used
N/A
13.5.2
Type B coated printed circuit boards complying with
IEC 60664-3 (basic insulation only)
IEC 60664-3 (basic insulation only)
No type B coated printed
circuit boards
circuit boards
N/A
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
clearances and creepage distances comply with
13.3 and 13.4
No uncemented joints
N/A
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N/A
Temperature cycle test and dielectric strength test
N/A
13.7
Enclosed, enveloped or hermetically sealed parts
not conductively connected to the mains,
clearances and creepage distances as in table 12
not conductively connected to the mains,
clearances and creepage distances as in table 12
No such part used
N/A
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
No such part used
N/A
Page 18 of 44
Report No.: 162890
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
14
Components
14.1
Resistors
N/A
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
No such resistors
N/A
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
Not used.
N/A
Resistors separately approved ............................... :
N/A
14.2
Capacitors and RC units
P
Capacitors separately approved :
Yes, see below
P
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition :
No Y capacitors.
N/A
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition …: Capacitors C904 certified
according to IEC 60384-14
P
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ...................... :
connected to the mains: tests for X2 ...................... :
No such capacitors
N/A
14.2.5
Capacitors with volume exceeding 1750 mm³,
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better ....................................................................... :
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better ....................................................................... :
Several E. cap. Vol. >1750mm
3
but metal cases.
N/A
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1, 4.38
category B or better ................................................ :
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1, 4.38
category B or better ................................................ :
Several E. cap. Vol. >1750mm
3
but metal cases.
N/A
Shielded by a barrier acc. To 20.1.4/table 21 or metal
N/A
14.3
Inductors and windings
P
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
Transformers evaluated
according to 14.3.3, 14.3.4
and 14.3.5.
according to 14.3.3, 14.3.4
and 14.3.5.
P
14.3.1
Transformers and inductors marked with
manufacturer’s name and type ............................... :
manufacturer’s name and type ............................... :
Adequate marking applied.
Manufacturer`s ID and type no.
Manufacturer`s ID and type no.
P
Transformers and inductors separately approved .:
No
N/A
14.3.2
General
Isolating transformers
P
Insulation material complies with clause 20.1.4
Considered. The insulation
material of isolating transf.
complies with flammability cate
gory of Table 21.
material of isolating transf.
complies with flammability cate
gory of Table 21.
P
14.3.3
Constructional requirements
P
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
(see appended table 13)
P
Page 19 of 44
Report No.: 162890
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
14.3.3.2
Transformers meet the constructional requirements (see appended table 14.3.3)
P
14.3.4
Separation between windings
P
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation) :
between hazardous live parts and accessible parts
(double or reinforced insulation) :
Double or reinforced
insulation between primary
and secondary windings
according to clause 8.8.
(see appended table 14.3.3)
insulation between primary
and secondary windings
according to clause 8.8.
(see appended table 14.3.3)
P
Coil formers and partition walls > 0,4 mm
Main and Sub transf. bobbin
fulfils the requirement of
reinforced insulation: bobbin
thickness > 0.4 mm.
fulfils the requirement of
reinforced insulation: bobbin
thickness > 0.4 mm.
P
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
Class II apparatus.
No such transformer used.
No such transformer used.
N/A
14.3.4.3
Separating transformers with at least basic
insulation
insulation
Windings of Class II
construction used.
construction used.
N/A
14.3.5
Insulation between HAZARDOUS LIVE parts and
ACCESSIBLE parts
ACCESSIBLE parts
P
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
Double or reinforced insulation
between hazardous live
windings and accessible
conductive parts
between hazardous live
windings and accessible
conductive parts
P
Coil formers and partition walls > 0,4 mm
Main and Sub transf. bobbin
fulfils the requirement of
reinforced insulation: bobbin
thickness > 0.4 mm.
fulfils the requirement of
reinforced insulation: bobbin
thickness > 0.4 mm.
P
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
Windings of Class II
construction used.
construction used.
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
14.4
High voltage components
No high-voltage components
N/A
High-voltage components and assemblies: U > 4 kV
(peak) separately approved
(peak) separately approved
N/A
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N/A
Page 20 of 44
Report No.: 162890
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N/A
14.5
Protective devices
P
Protective devices used within their ratings
Thermal link and fuses
P
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
Certified protective devices
applied (thermal-links and
fuses).
See appended table,
list of critical components.
applied (thermal-links and
fuses).
See appended table,
list of critical components.
P
14.5.1.1
a) Thermal cut-outs separately approved
No thermal cut-outs.
N/A
b) Thermal cut-outs tested as part of the submission
N/A
14.5.1.2
a) Thermal links separately approved
Thermal link in main transf.,
separately approved compo.
See appended table, list of
critical components.
separately approved compo.
See appended table, list of
critical components.
P
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
No thermal device
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
Fuses are approved component
according to IEC 60127.
See appended table, list of
critical components.
according to IEC 60127.
See appended table, list of
critical components.
P
14.5.2.2
Correct marking of fuse-links adjacent to holder ... : The following marking applied;
Mains fuses;
F901: T4A L 250V
F901: T4A L 250V
Secondary fuse;
F110: T3.15A L 250V
F111: T3.15A L 250V
F110: T3.15A L 250V
F111: T3.15A L 250V
P
14.5.2.3
Not possible to connect fuses in parallel ................ : No fuses holder so designed
that fuse-links can be
connected in parallel.
connected in parallel.
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ......... :
replacing fuse-links without the use of a tool ......... :
No replacement of fuses
possible by hand.
possible by hand.
P
14.5.3
PTC thermistors comply with IEC 60730-1
No PTC`s thermistors
N/A
PTC devices (15 W) category V-1 or better
N/A
14.5.4
Circuit protectors have adequate breaking capacity
and their position is correctly marked
and their position is correctly marked
Only standard fuses used.
N/A