Report No.: 162890 
 
 
ATTACHMENT 3 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
Annex ZB 
 
Annex ZB 
(normative) 
Special national conditions 
Special national condition: National characteristic or practice that cannot be changed even over a long 
period, e.g. climatic conditions, electrical earthing conditions. 
NOTE If it affects harmonization, it forms part of the European Standard. 
For the countries in which the relevant special national conditions apply these provisions are normative, 
for other countries they are informative. 
Add the following special national conditions: 
5.4 
 
Finland, Norway and Sweden 
To the end of 5.4 the following is added: 
CLASS I apparatus which is intended for connection 
to the building installation wiring via a plug or an 
appliance coupler, or both and in addition is 
intended for connection to other apparatus or a 
network shall, if safety relies on connection to 
protective earth or if surge suppressors are 
connected between the network TERMINALS and 
ACCESSIBLE parts, have a marking stating that the 
apparatus must be connected to an MAINS socket-
outlet with protective earth. 
The marking text in the applicable countries shall be 
as follows: 
In Finland: “Laite on liitettävä 
suojamaadoituskoskettimilla varustettuun 
pistorasiaan” 
In Norway: “Apparatet må tilkoples jordet 
stikkontakt” 
In Sweden: "Apparaten skall anslutas till jordat 
uttag" 
Class II apparatus 
N/A 
 
 
 
Page 10 of 11 
 
Report No.: 162890 
 
 
ATTACHMENT 3 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
5.4.1 
Norway and Sweden  
To the end of 5.4.1 (after the compliance statement) the 
following is added:  
The screen of the cable distribution system is normally 
not earthed at the entrance of the building and there is 
normally no equipotential bonding system within the 
building. Therefore the protective earthing of the building 
installation need to be isolated from the screen of a 
cable distribution system.  
It is however accepted to provide the insulation external 
to the equipment by an adapter or an interconnection 
cable with galvanic isolator, which may be provided by 
e.g. a retailer.  
The user manual shall then have the following or similar 
information in Norwegian and Swedish language 
respectively, depending on in what country the 
equipment is intended to be used in:  
“Equipment connected to the protective earthing of the 
building installation through the mains connection or 
through other equipment with a connection to protective 
earthing – and to a cable distribution system using 
coaxial cable, may in some circumstances create a fire 
hazard. Connection to a cable distribution system has 
therefore to be provided through a device providing 
electrical isolation below a certain frequency range 
(galvanic isolator, see EN 60728-11)”  
NOTE In Norway, due to regulation for installations of 
cable distribution systems, and in Sweden, a galvanic 
isolator shall provide electrical insulation below 5 MHz. 
The insulation shall withstand a dielectric strength of 1,5 
kV r.m.s., 50 Hz or 60 Hz, for 1 min.  
Translation to Norwegian (the Swedish text will also be 
accepted in Norway):  
“Utstyr som er koplet til beskyttelsesjord via nettplugg 
og/eller via annet jordtilkoplet utstyr – og er tilkoplet et 
kabel-TV nett, kan forårsake brannfare. For å unngå 
dette skal det ved tilkopling av utstyret til kabel-TV nettet 
installeres en galvanisk isolator mellom utstyret og 
kabel-TV nettet.”  
Translation to Swedish:  
”Utrustning som är kopplad till skyddsjord via jordat 
vägguttag och/eller via annan utrustning och samtidigt är 
kopplad till kabel-TV nät kan i vi
ssa fall medfőra risk főr 
brand.  
Főr att undvika detta skall vid anslutning av utrustningen 
till kabel-TV nät galvanisk isolator finnas mellan 
utrustningen och kabel-TV nätet.” 
Class II apparatus 
N/A 
 
 
 
Page 11 of 11 
 
Report No.: 162890 
 
 
ATTACHMENT 3 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
15.1.1 
Denmark  
The text of the Danish SNC in EN 60065:2002 has 
been modified as follows:  
To the first paragraph the following is added:  
In Denmark, supply cords of single-phase appliances 
having a rated current not exceeding 13 A shall be 
provided with a plug according to the Heavy Current 
Regulations Section 107-2-D1.  
Appliances of CLASS I provided with socket-outlets 
with earth contact or which are intended to be used in 
locations where protection against indirect contact is 
required according to the wiring rules shall be 
provided with a plug in accordance with the Heavy 
Current Regulations, Section 107-2-D1 standard 
sheet DK 2-1a.  
To the second paragraph the following is added:  
Socket outlets intended for providing power to CLASS 
II apparatus with a rated current of 2,5 A shall be in 
accordance with the Heavy Current Regulation, 
Section 107-2-D1 standard sheet DKA 1-4a.  
Other current ratings socket outlets shall be in 
compliance with the Heavy Current Regulation, 
Section 107-2-D1 standard sheet DKA 1-3a or DKA 
1-3b.  
To the third paragraph the following is added:  
Mains socket-outlets with earthing contact shall be in 
compliance with the Heavy Current Regulation, 
Section 107-2-D1 standard sheet DK 1-3a, DK 1-5a 
or DK 1-7a.  
Justification: Heavy Current Regulations, Section 
107-2-D1 
No socket-outlets 
N/A 
 
 
 
Page 1 of 5 
 
Report No.: 162890 
 
 
ATTACHMENT 4 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
ANNEX TO TEST REPORTS 
REGULATORY REQUIREMENTS FOR SINGAPORE 
Annex Form No. .............................. : 
SG_RR_A 
Annex Form Originator ..................... : 
TÜV SÜD PSB Pte Ltd 
Master Annex Form .......................... : 
2008-03 
Copyright © 2008 IEC System for Conformity Testing and Certification of Electrical Equipment 
(IECEE), Geneva, Switzerland. All rights reserved. 
 
No 
Items 
Requirements 
Result - Remark 
Verdict 
The following is the national differences in accordance with safety authority website 
www.spring.gov.sg/safety, ref. Singapore Consumer Protection (Safety Requirements) – Information 
Booklet – Chapter 7. 
7 SAFETY AUTHORITY’S REQUIREMENTS 
The Safety Authority monitors the safety of the controlled goods sold in Singapore by investigating 
all complaints, incidents and accidents reported to the authority. Experiences gained are translated 
into the Safety Authority’s Requirements. These requirements are to be fulfilled in addition to the 
applicable safety standards. 
No 
Items 
Requirements 
Result - Remark 
Verdict 
Applicable to all products 
Test certificate / 
Test report 
Test certificate / Test report more  
than three (3) years old shall be  
rejected. 
Noted
 
 
Applicable to all electrical products 
All appliances 
All appliances must be tested to 230 
VAC. 
230 Vac covered.  
Voltage selector 
(voltage mis-
match test) 
Appliance fitted with voltage 
selector shall be tested as follows: 
Connect appliance to 230 VAC 
mains with voltage selector switch 
to settings not suitable for operation 
at 230 VAC. 
No voltage selector. 
N/A 
Tropical 
condition test 
All appliances (with tropical test 
requirements in applicable 
Standards) shall comply with the 
tropical condition test as stated in 
the relevant IEC Standards. 
Comply
 