Harman Kardon AVR 161 (serv.man4) EMC - CB Certificate ▷ View online
Page 25 of 50
Report No.: 232105
IEC 60065
Clause Requirement
+
Test
Result
Verdict
TRF No. IEC60065K
15.3.1
Adequate terminals for connection of permanent
wiring
wiring
N/A
15.3.2
Reliable connection of non-detachable cords
N/A
Not soldered to conductors of a printed circuit board
N/A
Adequate clearances and creepage distances
between connections should a wire break away
between connections should a wire break away
N/A
Wire secured by additional means to the
conductor
conductor
No screws and nuts clamping
conductors used.
conductors used.
N/A
15.3.3
Screws and nuts clamping conductors have
adequate threads: ISO 261, ISO 262 or similar
adequate threads: ISO 261, ISO 262 or similar
No such terminal used.
N/A
15.3.4
Soldered conductors wrapped around terminal prior
to soldering or held in place by additional means
to soldering or held in place by additional means
N/A
Clamping of conductor and insulation if not soldered
or held by screws
or held by screws
N/A
15.3.5
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current of
the equipment
sectional area of conductors, for the rated current of
the equipment
N/A
15.3.6
Terminals to 15.3.3 have sizes required by table 16
N/A
15.3.7
Terminals clamp conductors between metal and
have adequate pressure
have adequate pressure
N/A
Terminals designed to avoid conductor slipping out
when tightened or loosened
when tightened or loosened
N/A
Terminals adequately fixed to avoid loosening when
the clamping is tightened or loosened and stress on
internal wiring is avoided
the clamping is tightened or loosened and stress on
internal wiring is avoided
N/A
15.3.8
Terminals carrying a current more than 0,2 A:
contact pressure not transmitted by insulating
material except ceramic
contact pressure not transmitted by insulating
material except ceramic
N/A
15.3.9
Termination of non-detachable cords: wires
terminated near to each other
terminated near to each other
N/A
Terminals located and shielded: test with 8 mm
strand
strand
N/A
15.4
Devices forming a part of the mains plug
No devices forming a part of
the mains plug.
the mains plug.
N/A
15.4.1
No undue strain on mains socket-outlets
N/A
15.4.2
Device complies with standard for dimensions of
mains plugs
mains plugs
N/A
15.4.3
Device has adequate mechanical strength (tests
a,b,c)
a,b,c)
N/A
Page 26 of 50
Report No.: 232105
IEC 60065
Clause Requirement
+
Test
Result
Verdict
TRF No. IEC60065K
16
External flexible cords
16.1
Mains cords sheathed type, complying with
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ............................................................ :
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ............................................................ :
Sheathed PVC cord complying
with IEC 60227 (GB5023.5
for China).
with IEC 60227 (GB5023.5
for China).
See appended table, list of
critical components.
critical components.
P
Non-detachable cords for Class I have green/yellow
core for protective earth
core for protective earth
Class II apparatus
N/A
16.2
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the
equipment
sectional area for rated current consumption of the
equipment
The cord is min 0.75 mm²
within the current rating.
within the current rating.
See appended table, list of
critical components
critical components
P
16.3
a) Flexible cords not complying with 16.1, used for
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
No interconnecting cords.
N/A
b) Flexible cords not complying with 16.1, withstand
bending and mechanical stress (3.2 of IEC 60227-2)
bending and mechanical stress (3.2 of IEC 60227-2)
No interconnecting cords.
N/A
16.4
Flexible cords used for connection between
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
No interconnecting cords.
N/A
16.5
Adequate strain relief on external flexible cords
Appliance inlet provided
N/A
Not possible to push cord back into equipment
N/A
Strain relief device unlikely to damage flexible
cord
cord
N/A
For mains cords of Class I equipment, hazardous
live conductors become taut before earth conductor
live conductors become taut before earth conductor
Class II equipment
N/A
16.6
Apertures for external flexible cord: no risk of
damage to the cord during assembly or movement
in use
damage to the cord during assembly or movement
in use
Appliance inlet provided
N/A
16.7
Transportable musical instruments and amplifiers
fitted with detachable cord set with appliance inlet to
IEC 60320-1
fitted with detachable cord set with appliance inlet to
IEC 60320-1
The apparatus is not a
transportable musical
instrument and amplifier
transportable musical
instrument and amplifier
N/A
Transportable musical instruments and amplifiers
fitted with detachable cord sets or with means of
stowage to protect the cord
fitted with detachable cord sets or with means of
stowage to protect the cord
N/A
Page 27 of 50
Report No.: 232105
IEC 60065
Clause Requirement
+
Test
Result
Verdict
TRF No. IEC60065K
17
Electrical connections and mechanical fixings
17.1
Torque test to table 20
See below
P
- screws into metal: 5 times
(see appended table 17.1)
P
- screws into non-metallic material: 10 times
(see appended table 17.1)
P
17.2
Correct introduction into female threads in non-
metallic material
metallic material
Correct introduction of screws
into non-metallic material for
top cover.
into non-metallic material for
top cover.
P
17.3
Cover fixing screws: captive
Captivity not necessary
N/A
Non-captive fixing screws: no hazard when replaced
by a screw whose length is 10 times its diameter
by a screw whose length is 10 times its diameter
Tested with screw with
10 times diameter.
10 times diameter.
P
17.4
No loosening of conductive parts carrying a current
> 0,2 A
> 0,2 A
Loosening is sufficiently
prevented.
prevented.
P
17.5
Contact pressure not transmitted through plastic
other than ceramic for connections carrying a current
> 0,2 A
other than ceramic for connections carrying a current
> 0,2 A
No contact pressure
transmitted through insulating
material.
transmitted through insulating
material.
P
17.6
Stranded conductors of flexible supply cords
carrying a current > 0,2 A with screw terminals not
consolidated by solder
carrying a current > 0,2 A with screw terminals not
consolidated by solder
No such screw terminals.
N/A
17.7
Cover fixing devices other than screws have
adequate strength and their positioning is
unambiguous
adequate strength and their positioning is
unambiguous
No cover fixing devices
other than screws
other than screws
N/A
17.8
Fixing devices for detachable legs or stands
provided
provided
No detachable legs or stands
provided.
provided.
N/A
17.9
Internal pluggable connections, affecting safety,
unlikely to become disconnected
unlikely to become disconnected
Connections comply,
checked by inspection.
checked by inspection.
P
18
Mechanical strength of picture tubes and protection against the effects of
implosion
implosion
18.1
Picture tube separately approved to IEC 61965 ... : No picture tube used
N/A
Picture tube separately approved to 18.2 .............. :
N/A
18.2
Non-intrinsically protected tubes tested to 18.2
N/A
19
Stability and mechanical hazards
Mass of the equipment exceeding 7 kg ................. :
Mass: 4.6 kg
Apparatus intended to be fastened in place –
suitable instructions ................................................ :
suitable instructions ................................................ :
No
N/A
19.1
Test on a plane, inclined at 10
o
to the horizontal
N/A
19.2
100 N force applied vertically downwards
N/A
19.3
100 N force, or 13% of weight, applied horizontally
to point of least stability
to point of least stability
Mass: < 25 kg or < 1 m
N/A
Page 28 of 50
Report No.: 232105
IEC 60065
Clause Requirement
+
Test
Result
Verdict
TRF No. IEC60065K
19.4
Edges or corners not hazardous
There are no hazardous
edges or corners when the
apparatus is operating in
normal position.
edges or corners when the
apparatus is operating in
normal position.
P
19.5
Glass surfaces (exc.laminated) with an area
exceeding 0,1 m² or maximum dimension
> 450 mm, pass the test of 19.5.1
exceeding 0,1 m² or maximum dimension
> 450 mm, pass the test of 19.5.1
No glass surface.
N/A
19.6
Wall or ceiling mountings adequate
No wall or ceiling mountings
N/A
20
Resistance to fire
20.1
Electrical components and mechanical parts
P
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
N/A
b) Exemption for small components as defined in
20.1
20.1
PCB is of flammability class
V-0, and exception is made
for small components.
V-0, and exception is made
for small components.
P
20.1.1 Electrical
components
meet the requirements of
Clause 14 or 20.1.4
Electrical components
comply with flammability
requirements in clause 14.
comply with flammability
requirements in clause 14.
P
20.1.2
Insulation of internal wiring working at voltages
> 4 kV or leaving an internal fire enclosure, or
located within the areas mentioned in Table 21, not
contributing to the spread of fire
> 4 kV or leaving an internal fire enclosure, or
located within the areas mentioned in Table 21, not
contributing to the spread of fire
No wires working at
voltages > 4kV or leaving
an internal fire enclosure.
voltages > 4kV or leaving
an internal fire enclosure.
N/A
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC 60707, unless used in a fire
enclosure
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC 60707, unless used in a fire
enclosure
All PCB are of base material
with flammability category
V-0 (UL approved),
See list of critical components.
with flammability category
V-0 (UL approved),
See list of critical components.
P
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
No voltage > 400 V (peak)
N/A
20.1.4
Components and parts not covered by 20.1.1,
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
Bobbin (base) of transformers
and Line filters are complying
with the relevant flammability
category in Table 21.
and Line filters are complying
with the relevant flammability
category in Table 21.
P
Components and parts as above but shielded from
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
No such components
N/A
Apparatus with voltages >4kV under normal
operating conditions and distances to the enclosure
exceed those specified Table 21, flammability
classification HB40 or better is required for the
enclosure
operating conditions and distances to the enclosure
exceed those specified Table 21, flammability
classification HB40 or better is required for the
enclosure
Normal operating voltage
< 4kV
< 4kV
N/A
Click on the first or last page to see other AVR 161 (serv.man4) service manuals if exist.