Report No.: 232105
IEC 60065
Clause Requirement
+
Test
Result
Verdict
TRF No. IEC60065K
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
No hygroscopic materials
used
used
N/A
8.4
No risk of electric shock from accessible parts or
from parts rendered accessible following the
removal of a cover which can be removed by hand
from parts rendered accessible following the
removal of a cover which can be removed by hand
No cover removable by hand.
N/A
8.5
Class I equipment
Class II equipment
N/A
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N/A
Resistors bridging basic insulation complying with
14.1 a)
14.1 a)
N/A
Capacitors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
N/A
Protective earthing terminal
N/A
8.6
Class II equipment and Class II constructions within
Class I equipment
Class I equipment
Refer to below
P
Double or reinforced insulation between hazardous
live parts and accessible parts
live parts and accessible parts
Double/Reinforced insulation
complies with requirements
specified in clause 10 and 13.
complies with requirements
specified in clause 10 and 13.
P
Components bridging double or reinforced insulation
complying with 14.1 a) or 14.3
complying with 14.1 a) or 14.3
The apparatus have isolated
transformer complies with
clause 14.3.
transformer complies with
clause 14.3.
P
Basic insulation bridged by components complying
with 14.3.4.3.
with 14.3.4.3.
No such components
N/A
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.1 a)
bridged by a capacitor complying with 14.1 a)
No such capacitors.
N/A
Double or reinforced insulation being bridged with 2
capacitors in series complying with 14.2.1 a)
capacitors in series complying with 14.2.1 a)
CY91, CY92 and CY96 cap.,
bridging reinforced insulation
in the apparatus.
bridging reinforced insulation
in the apparatus.
P
Double or reinforced insulation being bridged with a
single capacitor complying with 14.2.1 b)
single capacitor complying with 14.2.1 b)
CY93, CY94 and CY95 cap.,
bridging reinforced insulation
in the apparatus.
bridging reinforced insulation
in the apparatus.
P
8.7
This clause is void
—
8.8
Basic or supplementary insulation > 0,4 mm (mm) :
N/A
Reinforced insulation > 0,4 mm (mm) .................... : a. Transformers bobbin.
ref.
14.3.
b. Optocouplers inner
insulation, ref. 14.11.
insulation, ref. 14.11.
P
Thin sheet insulation (excluding non-separable thin
sheet insulation. See 8.22)
sheet insulation. See 8.22)
Insulation in TF91, TF92 and
TF93 transformers
TF93 transformers
P
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N/A
Page 14 of 50
Report No.: 232105
IEC 60065
Clause Requirement
+
Test
Result
Verdict
TRF No. IEC60065K
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N/A
Reinforced insulation, two layers each of which meet
10.3
10.3
N/A
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
Thin sheet insulation used in
TF91, TF92 and TF93
transformer.
(see appended table 14.3.3)
TF91, TF92 and TF93
transformer.
(see appended table 14.3.3)
P
8.9
Adequate insulation between internal hazardous live
conductors and accessible parts
conductors and accessible parts
Double insulated
P
Adequate insulation between internal hazardous live
parts and conductors connected to accessible parts
parts and conductors connected to accessible parts
Single insulated but safely
anchored.
anchored.
P
8.10
Double insulation between conductors connected to
the mains and accessible parts.
the mains and accessible parts.
Double insulated according to
8.9 and 10.3
8.9 and 10.3
P
Double insulation between internal hazardous live
parts and conductors connected to accessible parts.
parts and conductors connected to accessible parts.
Single insulated but safely
anchored.
anchored.
N/A
8.11
Detaching of wires
P
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
Inlet connected wires
hooked-in before soldered.
Other primary wires connected
with multi-contact housing.
hooked-in before soldered.
Other primary wires connected
with multi-contact housing.
P
Vibration test carried out ......................................... :
See clause 12.1.2
—
8.12
This clause is void
—
8.13
Adequate fastening of windows, lenses, lamp covers
etc. (pull test 20 N for 10 s)
etc. (pull test 20 N for 10 s)
Adequately fastened.
P
8.14
Adequate fastening of covers (push/pull test 50 N for
10 s)
10 s)
Covers adequately fastened
with screws.
with screws.
P
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges
due to hot parts or sharp edges
Wires safely anchored away
from parts with high
temperature.
from parts with high
temperature.
P
8.16
Only special supply equipment can be used
Not supplied by a special
supply apparatus
supply apparatus
N/A
8.17
Insulated winding wire without additional interleaved
insulation
insulation
No such winding wire
N/A
8.18
Endurance test as required by 8.17
No such insulation winding is
used.
used.
N/A
8.19
Disconnection from the mains
See below
P
8.19.1 Disconnect
device
Appliance coupler is used as
disconnect devices.
disconnect devices.
P
All-pole switch or circuit breaker with >3mm contact
separation
separation
No all-pole switch or circuit
breaker.
breaker.
N/A
Page 15 of 50
Report No.: 232105
IEC 60065
Clause Requirement
+
Test
Result
Verdict
TRF No. IEC60065K
8.19.2
Mains switch ON indication
No mains switch, however
LED for ON indication
provided.
LED for ON indication
provided.
P
8.20
Switch not fitted in the mains cord
No switch in the mains cord.
P
8.21
Bridging components comply with clause 14
N/A
8.22
Non-separable thin sheet material
N/A
9
Electric shock hazard under normal operating conditions
9.1
Testing on the outside
P
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
No voltages >1000 V ac or
>1500 V dc
>1500 V dc
N/A
9.1.1.1
a) Open circuit voltages
Mains input voltage
> 35 Vac, see below.
> 35 Vac, see below.
b) Touch current measured from terminal devices
using the network in annex D ................................. :
using the network in annex D ................................. :
U1: Max. 0.54 Vpeak
U2: Max. 0.32 Vpeak
(Tested at 264V / 60Hz)
U2: Max. 0.32 Vpeak
(Tested at 264V / 60Hz)
P
c) Discharge not exceeding 45 μC
No part or contact of a
terminal with stored voltages
between 60V - 15 kV.
terminal with stored voltages
between 60V - 15 kV.
N/A
d) Energy of discharge not exceeding 350 mJ
No part or contact of a terminal
with stored voltages exceeding
15kV.
N/A
9.1.1.2
Test with test finger and test probe
No access to hazardous
live parts
live parts
P
9.1.2
No hazardous live shafts of knobs, handles or levers No live shafts of knobs,
handles or levers.
N/A
9.1.3
Ventilation holes and other holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
No access for the test pin.
P
9.1.4
Terminal devices tested with 1 mm x 20 mm test pin
(10 N); test probe D of IEC 61032
(10 N); test probe D of IEC 61032
Does not reach hazardous
live parts
live parts
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
Does not reach hazardous
live parts
live parts
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
No pre-set controls
N/A
9.1.6
No shock hazard due to stored charge on withdrawal
of the mains plug; voltage (V) after 2 s .................. :
of the mains plug; voltage (V) after 2 s .................. :
32Vdc after 2 s,
Bleeder resistor provided.
See clause 14.1 a), and
appended table, list of critical
components.
Bleeder resistor provided.
See clause 14.1 a), and
appended table, list of critical
components.
P
If C is not greater than 0,1 μF no test needed
> 0,1 μF
N/A
Page 16 of 50
Report No.: 232105
IEC 60065
Clause Requirement
+
Test
Result
Verdict
TRF No. IEC60065K
9.1.7
Resistance to external forces
P
a) Test probe 11 of IEC 61032 for 10 s (50 N)
Test with test finger result
in no hazard
in no hazard
P
b) Test hook of fig. 4 for 10 s (20 N)
Test with test hook results
in no hazard.
in no hazard.
P
c) 30 mm diameter test tool for 5 s (100 or 250 N)
Tested 100N result in no
hazard.
hazard.
P
9.2
No hazard after removing a cover by hand
No cover removable by hand
N/A
10 Insulation
requirements
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
Basic: >2.6 MΩ,
Reinforced: >5.2 MΩ after
surge test
Reinforced: >5.2 MΩ after
surge test
P
10.2
Humidity treatment 48 h or 120 h ........................... :
Performed for 120 h at temp.
40
40
C and humidity 93 %
P
10.3
Insulation resistance and dielectric strength between
mains terminals
mains terminals
(see appended table 10.3)
P
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class I)
BASIC or SUPPLEMENTARY insulation (Class I)
Class II apparatus
N/A
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II)
REINFORCED insulation (Class II)
(see appended table 10.3)
P
11 Fault
conditions
11.1
No shock hazard under fault condition
No electric shock hazard
under fault conditions.
under fault conditions.
P
11.2
Heating under fault condition
(see appended table 11.2)
P
Flames extinguish within 10 seconds
No flames
P
No hazard from softening solder
No softening of solder
P
Soldered terminations not used as protective
mechanism
mechanism
No soldered terminations
P
11.2.1
Measurement of temperature rises
(see appended table 11.2)
P
11.2.2
Temperature rise of accessible parts
(see appended table 11.2)
P
11.2.3
Temperature rise of parts, other than windings and
printed boards, providing electrical insulation
printed boards, providing electrical insulation
(see appended table 11.2)
P
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
(see appended table 11.2)
P
11.2.5
Temperature rise of windings
(see appended table 11.2)
P
11.2.6
Temperature rise of printed boards shall not exceed
the limits of table 3 by max. 100 K for max. 5 min
the limits of table 3 by max. 100 K for max. 5 min
No exceeding the limits of
Table 3.
Table 3.
N/A