Harman Kardon AVR 161 (serv.man4) EMC - CB Certificate ▷ View online
Page 29 of 50
Report No.: 232105
IEC 60065
Clause Requirement
+
Test
Result
Verdict
TRF No. IEC60065K
20.2 Fire
enclosure
N/A
20.2.1 Potential
ignition
sources with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
enclosure to V-1
No voltage > 4kV (peak)
N/A
20.2.2
Internal fire enclosures with openings not
exceeding 1 mm in width and with openings for
wires completely filled
exceeding 1 mm in width and with openings for
wires completely filled
N/A
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an
internal fire enclosure
internal fire enclosure
N/A
Page 30 of 50
Report No.: 232105
IEC 60065
Clause Requirement
+
Test
Result
Verdict
TRF No. IEC60065K
A
Annex A, Additional requirements for apparatus with protection against
splashing water
splashing water
A.5 Marking
and
instructions
N/A
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
apply
Not intended for outdoor use
N/A
A.10 Insulation
requirements
N/A
A.10.2
Splash and humidity treatment
N/A
A.10.2.1
Enclosure provides protection against splashing
water
water
N/A
A.10.2.2
Humidity treatment carried out for 7 days
N/A
B
Annex B, Apparatus to be connected to the TELECOMMUNICATION
NETWORKS
NETWORKS
Complies with IEC 62151 clause 1
No TNV circuits
N/A
Complies with IEC 62151 clause 2
N/A
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
modified to 2.4.10 of this standard
N/A
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
N/A
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this
standard
modified in accordance with annex B of this
standard
N/A
Complies with IEC 62151 clause 6
N/A
Complies with IEC 62151 clause 7
N/A
Complies with IEC 62151 annex A, B and C
N/A
Page 31 of 50
Report No.: 232105
IEC 60065
Clause Requirement
+
Test
Result
Verdict
TRF No. IEC60065K
L
ANNEX L, Additional requirements for electronic flash apparatus for
photographic purposes
photographic purposes
L. 5
Marking and instructions
N/A
L. 5.4
Instructions for battery chargers and Supply
apparatus indicating type or model number of flash
apparatus with which it is to be used
apparatus indicating type or model number of flash
apparatus with which it is to be used
No electronic flash apparatus
N/A
Instructions for flash apparatus indicating type or
model number of battery chargers or Supply
apparatus with which it is to be used
model number of battery chargers or Supply
apparatus with which it is to be used
N/A
L. 7
Heating under normal operating conditions
N/A
L7.1.5 &
L11.2.7
L11.2.7
Lithium batteries meet permissible temp rise in
Table 3, unless comply with 6.2.2.1 or 6.2.2.2 of IEC
60086-4
Table 3, unless comply with 6.2.2.1 or 6.2.2.2 of IEC
60086-4
No lithium batteries
N/A
L. 9
Electric shock hazard under normal operating
conditions
conditions
Not flash synchroniser
N/A
L. 9.1.1
Terminals to connection to synchroniser not
HAZARDOUS LIVE
HAZARDOUS LIVE
N/A
L.10 Insulation
requirements
N/A
L. 10.3.2
High frequency puls ignition
N/A
L. 12
Mechanical strength
N/A
L. 12.1.3
Windows for flash tubes are excluded from steel ball
impact test
impact test
N/A
L. 14
Components
N/A
L14.6.6
Mains switch characteristics appropriate to its
function under normal conditions
function under normal conditions
N/A
L. 20
Resistance to fire
N/A
L. 20.1 c)
Trigger coil for discharge purpose is not considered
to be a POTENTIAL IGNITION SOURCE
to be a POTENTIAL IGNITION SOURCE
N/A
Page 32 of 50
Report No.: 232105
TRF No. IEC60065K
7.1
TABLE: temperature rise measurements:
P
Power consumption in the OFF/Stand-by mode of
the functional switch (W) ........................................ :
the functional switch (W) ........................................ :
Less than 0.48 W
—
Operating Condition / Status
Standby mode;
Cond.
Un (V)
Hz
In (A)
Pn (W)
Uout (V)
Pout (W)
1 220 50 0.04
0.47
—
—
2 240 50 0.04
0.41
—
—
3 220 60 0.05
0.48
—
—
4 240 60 0.05
0.43
—
—
1 kHz input signal with maximum non-clipped output mode with loaded 5V/2.1 A through USB terminal
(Measured at “HIGH mode” of the transformer output, TF93 - see summary of testing for details);
(Measured at “HIGH mode” of the transformer output, TF93 - see summary of testing for details);
Cond.
Un (V)
Hz
In (A)
Pn (W)
Uout (V)
Pout (W)
5 264 50 1.80
276.5
F) 12.38 x 2 ch
S) 12.32 x 2 ch
S) 12.32 x 2 ch
C) 12.34 x 1 ch
F) 25.54 x 2 ch
S) 25.30 x 2 ch
S) 25.30 x 2 ch
C) 25.38 x 1 ch
6 264 60 1.75
275.6
1 kHz input signal with 1/8 of maximum non-clipped output mode with loaded 5V/2.1 A through USB terminal
(Measured at “HIGH mode” of the transformer output, TF93 - see summary of testing for details);
(Measured at “HIGH mode” of the transformer output, TF93 - see summary of testing for details);
Cond.
Un (V)
Hz
In (A)
Pn (W)
Uout (V)
Pout (W)
7 198 50 1.61
184.8
F) 4.37 x 2 ch
S) 4.35 x 2 ch
C) 4.36 x 1 ch
F) 3.19 x 2 ch
S) 3.16 x 2 ch
C) 3.17 x 1 ch
8 220 50 1.47
184.1
9 240 50 1.34
183.4
10 264 50
1.21
183.0
11 198 60
1.60
184.1
12 220 60
1.44
183.2
13 240 60
1.31
182.6
14 264 60
1.15
182.0
Click on the first or last page to see other AVR 161 (serv.man4) service manuals if exist.