Harman Kardon AVR 145 EMC - CB Certificate ▷ View online
- Page 3 of 32 -
www.nemko.com
Report No. 77024
TRF No: IEC/EN 60065F
Copy of marking plate:
- Page 4 of 32 -
www.nemko.com
Report No. 77024
TRF No: IEC/EN 60065F
Summary of testing:
The apparatus under test is A/V Surround Receiver of insulation class II.
The apparatus have Front / Center / Surround Amplifier Circuits, Tuner Circuit, Several
Signal In/Out terminals (RCA, Optical, RS-232, DMP) and Speaker terminals
(see also photos).
The equipment applied condition of tropical climates for Singapore.
Instructions :
The apparatus have Front / Center / Surround Amplifier Circuits, Tuner Circuit, Several
Signal In/Out terminals (RCA, Optical, RS-232, DMP) and Speaker terminals
(see also photos).
The equipment applied condition of tropical climates for Singapore.
Instructions :
Instructions/users manual is only in English. The information shall be given in a language
acceptable to the country where the apparatus is intended to be sold.
List of attachments:
ANNEX ZB TO EN 60 065, SPECIAL NATIONAL CONDITIONS
ANNEX ZC TO EN 60 065, A-DEVIATIONS
National Deviations for Singapore
Photos
Attachment, Tables to EN/IEC 60065 7
th
edition
- Page 5 of 32 -
www.nemko.com
Report No. 77024
TRF No: IEC/EN 60065F
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
3 GENERAL
REQUIREMENTS
Safety class of the apparatus ................................. :
Class II
P
4
GENERAL CONDITIONS OF TESTS
4.1.4 Ventilation
instructions
require the use of the test
box
No test box required. Tested
according to manufacturers
instructions
according to manufacturers
instructions
N
5 MARKING
Comprehensible and easily discernible
On front and rear side of the
enclosure
enclosure
P
Permanent durability against water and petroleum
spirit
spirit
Tested with water / spirit
P
5.1 Identification,
maker, model ................................... :
Brand: Harman / Kardon
Model: AVR 145/230.
See copy of marking plate.
Model: AVR 145/230.
See copy of marking plate.
P
Class II symbol if applicable
Class II symbol is applied in
according to IEC 60417-5172.
according to IEC 60417-5172.
P
Rated supply voltage and symbol .......................... :
AC-symbol (
~
) with 230V
marked
P
Frequency if safety dependant
50Hz
P
Rated current or power consumption ..................... :
280W
P
5.2 Earth
terminal
Class II apparatus
N
Hazardous live terminals
No live terminals.
The output signal will rise to
33Vp at Pmax, if the speaker
terminal is disconnected,
No hazard.
The output signal will rise to
33Vp at Pmax, if the speaker
terminal is disconnected,
No hazard.
P
Supply output terminals (other than mains)
The power and current marked
closed to the socket-outlet;
closed to the socket-outlet;
SWITCHED (50W, 0.5A MAX)
P
5.3
Use of triangle with exclamation mark
Correct symbol applied:
Imprinted on rear side in
connection with CAUTION of
opening. Further; no incorrect
use of this symbol is found.
Imprinted on rear side in
connection with CAUTION of
opening. Further; no incorrect
use of this symbol is found.
P
5.4
Instructions for use
User information in the
following language: English.
See comments in Summary of
Testing.
following language: English.
See comments in Summary of
Testing.
P
- Page 6 of 32 -
www.nemko.com
Report No. 77024
TRF No: IEC/EN 60065F
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
5.4.1
Mains powered equipment not exposed to dripping
or splashing. Warning concerning objects filled
with liquid, etc.
or splashing. Warning concerning objects filled
with liquid, etc.
The user manual includes
information about danger
concerning dripping or
splashing and objects filled
with liquids.
information about danger
concerning dripping or
splashing and objects filled
with liquids.
P
Hazardous live terminals, instructions for wiring
No hazardous live terminals
N
Instructions for replacing lithium battery
No lithium battery in the
equipment
equipment
N
Instructions for modem if fitted
None
N
Class I earth connection warning
Class II apparatus
N
Instructions for multimedia system connection
Not applicable
N
Special stability warning for fixed installation
Not for fixed installation
N
5.4.2
Disconnect device: plug/coupler or all-
pole mains switch location, accessibility and marki
ngs
pole mains switch location, accessibility and marki
ngs
Plug is regarded as disconnect
device and is readily operable.
device and is readily operable.
P
Instructions for permanently connected equipment
Not permanently connected
equipment
equipment
N
6 HAZARDOUS
RADIATION
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No CRT
N
6.1
EN 60065
European Council Directive 96/29/Euratom of 13
May 1996 10cm from outer surface of apparatus
<1µSv/h (0,1mR/h)
May 1996 10cm from outer surface of apparatus
<1µSv/h (0,1mR/h)
N
6.2
Laser radiation, emission limits to IEC 60825-1 .... :
No laser
N
Emission limits under fault conditions .................... :
N
Click on the first or last page to see other AVR 145 service manuals if exist.