Harman Kardon AVR 145 EMC - CB Certificate ▷ View online
- Page 15 of 32 -
www.nemko.com
Report No. 77024
TRF No: IEC/EN 60065F
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
Double or reinforced insulation
between hazardous live
windings and accessible
conductive parts.
between hazardous live
windings and accessible
conductive parts.
P
Coil formers and partition walls > 0,4 mm
The bobbin fulfils the requireme
nt
of reinforced insulation; bobbin
thickness > 0,4 mm.
nt
of reinforced insulation; bobbin
thickness > 0,4 mm.
P
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
Windings of Class II
construction used.
construction used.
N
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N
14.4
High voltage components
No high voltage components
N
High-voltage components and assemblies:
U > 4 kV (peak) separately approved
U > 4 kV (peak) separately approved
N
Component meets category V-1 of IEC 60707
N
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N
14.5 Protective
devices
P
Protective devices used within their ratings
Thermal links and fuses
P
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
Certified protective devices
applied. See appended table,
list of critical components.
applied. See appended table,
list of critical components.
P
14.5.1.1
a) Thermal cut-outs separately approved
None
N
b) Thermal cut-outs tested as part of the
submission
submission
N
14.5.1.2
a) Thermal links separately approved
The thermal links in main and
sub transformers, separately
approved, see appended table,
list of critical components.
sub transformers, separately
approved, see appended table,
list of critical components.
P
b) Thermal links tested as part of the submission
N
14.5.1.3
Thermal devices re-settable by soldering
No such thermal device
N
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
Fuses are certified according
to IEC60127
to IEC60127
P
- Page 16 of 32 -
www.nemko.com
Report No. 77024
TRF No: IEC/EN 60065F
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
14.5.2.2
Correct marking of fuse-links adjacent to holder ... :
Correct marking applied close
to the fuse;
F901: T4A L 250V,
F902: T2.5A L 250V
to the fuse;
F901: T4A L 250V,
F902: T2.5A L 250V
P
14.5.2.3
Not possible to connect fuses in parallel ............... :
No fuse holder so designed that
fuse-links can be connected in
parallel
fuse-links can be connected in
parallel
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ......... :
replacing fuse-links without the use of a tool ......... :
No replacement of fuse
possible by hand.
possible by hand.
P
14.5.3
PTC-S thermistors comply with IEC 60730-1
None
N
PTC-S devices (15 W) category V-1 or better
None
N
14.5.4 Circuit
protectors
have adequate breaking capacity
and their position is correctly marked
No such components
N
14.6 Switches
P
14.6.1 a)
Separate testing to IEC 61058 including:
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3
and
V-0 compliance with annex G, G.1.1
Yes,
Mains switch and relay provided.
Certified acc. to IEC61058-1.
- Mains switch, certified by VDE,
-
Mains relay, certified by SEMKO.
See appended table, list of
critical components.
Mains switch and relay provided.
Certified acc. to IEC61058-1.
- Mains switch, certified by VDE,
-
Mains relay, certified by SEMKO.
See appended table, list of
critical components.
P
14.6.1 b)
Tested in the apparatus:
N
Switch controlling > 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
N
Switch controlling > 0.2A with open contact
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
N
Switch controlling < 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
N
14.6.2
Switch tested to 14.6.1 b) constructed to IEC
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
Separately approved switch
and relay.
and relay.
N
14.6.3
Switch tested to 14.6.1 b) compliant with IEC
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
Separately approved switch
and relay.
and relay.
N
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
strength
Separately approved switch
and relay.
and relay.
N
- Page 17 of 32 -
www.nemko.com
Report No. 77024
TRF No: IEC/EN 60065F
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 61058-1
additional tests to IEC 61058-1
Measured surge current through,
- Mains switch =
- Mains switch =
< 1 A.
- Mains relay = 37A * + 20 A **
*) Apparatus generated surge
**) Switched outlet surge
The measured surge current value
is less than rated surge current
rating of the mains relay (120A)
and switch (80A) - OK.
(The mains socket outlet is
controlled by the mains relay only).
*) Apparatus generated surge
**) Switched outlet surge
The measured surge current value
is less than rated surge current
rating of the mains relay (120A)
and switch (80A) - OK.
(The mains socket outlet is
controlled by the mains relay only).
P
Socket outlet current marking correct
Socket outlet marking:
SWITCHED (50W, 0.5A MAX)
P
14.7 Safety
interlocks
No safety interlocks
N
Safety interlocks to 2.8 of IEC 60950
N
14.8
Voltage setting devices
No voltage setting devices
N
Voltage setting device not likely to be changed
accidentally
accidentally
N
14.9 Motors
No motors
P
14.9.1
Endurance test on motors
N
Motor start test
N
Dielectric strength test
N
14.9.2
Not adversely affected by oil or grease etc.
N
14.9.3
Protection against moving parts
N
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet clause. B.8, B.9
and B.10 of IEC 60950, Annex B
motors and series motors meet clause. B.8, B.9
and B.10 of IEC 60950, Annex B
N
14.10 Batteries
No batteries
N
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
flammable gases
N
14.10.2
No possibility of recharging non-rechargeable
batteries
batteries
N
14.10.3
Recharging currents and times within manufacture
rs limits
rs limits
N
Lithium batteries discharge and reverse currents
within the manufacturers limits
within the manufacturers limits
N
- Page 18 of 32 -
www.nemko.com
Report No. 77024
TRF No: IEC/EN 60065F
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
14.10.4
Battery mould stress relief
N
14.10.5
Battery drop test
N
14.11 Optocouplers
No optocouplers
N
Optocouplers comply with Cl. 8
N
Internal and external dimensions to 13.1. or
alternatively 13.6 (jointed insulation)
alternatively 13.6 (jointed insulation)
N
14.12
Surge suppression varistors
No surge suppression varistors
N
Comply with IEC 61051-2
N
Not connected between mains and accessible
parts except for earthed parts of permanently
connected apparatus
parts except for earthed parts of permanently
connected apparatus
N
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12
thermal stress requirements of 14.12
N
15 TERMINALS
15.1.1
Mains plug, appliance inlet, interconnection
couplers and mains socket-outlet meet the
appropriate standard
couplers and mains socket-outlet meet the
appropriate standard
Approved mains plug and
socket-outlet provided,
see list of critical components.
socket-outlet provided,
see list of critical components.
P
15.1.2
Connectors for antenna, earth, audio, video or data:
P
No risk of insertion in mains socket-outlets
Only phonos, RCA, Optical,
RS-232, DMP, Antenna and
S-video terminals used.
Banana plug type speaker
terminal also used, but they are
accepted due to below note.
Note:
Banana plug type speaker
terminals are blocked in their
axial holes to prevent use of plugs
that can make permanent contac
t with a mains socket outlet.
RS-232, DMP, Antenna and
S-video terminals used.
Banana plug type speaker
terminal also used, but they are
accepted due to below note.
Note:
Banana plug type speaker
terminals are blocked in their
axial holes to prevent use of plugs
that can make permanent contac
t with a mains socket outlet.
P
No risk of insertion into audio or video: outlets
marked with the symbol of 5.2
marked with the symbol of 5.2
No sockets indicated with the
symbol
symbol
N
15.1.3
Output terminals of a.c. adaptors or similar devices
not compatible with household mains socket-
outlets
not compatible with household mains socket-
outlets
The equipment under test is
not an adaptor.
not an adaptor.
N
Click on the first or last page to see other AVR 145 service manuals if exist.