- Page 7 of 32 -
www.nemko.com
Report No. 77024
TRF No: IEC/EN 60065F
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
7
HEATING UNDER NORMAL OPERATING CONDITIONS
7.1
Temperature rises not exceeding specified values,
no operation of fuse links
no operation of fuse links
No fuse links operate during no
rmal operating conditions.
See also appended table.
rmal operating conditions.
See also appended table.
P
7.1.1
Temperature rise of accessible parts
(see appended table)
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table)
P
7.1.3
Temperature rise of parts acting as a support or as
a mechanical barrier
a mechanical barrier
(see appended table)
P
7.1.4
Temperature rise of windings
(see appended table)
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table)
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
No temperatures measured du
ring heating test and fault
condition tests require this
test (7.2) to be performed.
ring heating test and fault
condition tests require this
test (7.2) to be performed.
N
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
AGAINST ELECTRIC SHOCK
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
Considered
P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
Operation “By hand”
not possible
not possible
N
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
No hygroscopic materials
N
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
cover which can be removed by hand
No cover removable by hand
N
8.5
Class I equipment
Class II equipment
N
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N
Resistors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
N
8.6
Class II equipment and Class II constructions
within Class I equipment
within Class I equipment
Class II apparatus.
P
Reinforced or double insulation between
hazardous live parts and accessible parts
hazardous live parts and accessible parts
Double/Reinforced insulation
complies with requirements
specified in clause 10 and 13.
complies with requirements
specified in clause 10 and 13.
P
Components bridging reinforced or double
insulation complying with 14.1 a) or 14.3
insulation complying with 14.1 a) or 14.3
The apparatus have isolating
transformers.
transformers.
P
- Page 8 of 32 -
www.nemko.com
Report No. 77024
TRF No: IEC/EN 60065F
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
bridged by a capacitor complying with 14.2.1 a)
No such capacitors.
N
Reinforced or double insulation being bridged with
2 capacitors in series complying with 14.2.1 a)
2 capacitors in series complying with 14.2.1 a)
No such capacitors.
N
Reinforced or double insulation being bridged with
a single capacitor complying with 14.2.1 b)
a single capacitor complying with 14.2.1 b)
No such capacitors.
N
Basic insulation bridged by components complying
with 14.3.4.3
with 14.3.4.3
No such components
N
8.7
Basic insulation between parts at 35 V to 71 V
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
No parts at 35V to 71V (peak)
a.c. or 60V to 120V d.c.
a.c. or 60V to 120V d.c.
N
Reinforced or double insulation between circuits
operating at voltages between 35 V and 71 V
(peak) a.c. or between 60 V and 120 V d.c. and
hazardous live parts at higher voltage
operating at voltages between 35 V and 71 V
(peak) a.c. or between 60 V and 120 V d.c. and
hazardous live parts at higher voltage
No parts at 35-71V(peak) a.c. or
60-120V d.c.
60-120V d.c.
N
Separation by Class II isolating transformer
Isolating transformer according to
14.3.2. (Class II)
14.3.2. (Class II)
P
Separation by Class I transformer
N
Separation by earthed conductive part
N
8.8
Basic or supplementary insulation > 0,4 mm (mm) :
N
Reinforced
insulation > 0,4 mm (mm) .................... :
Transformer bobbin,
See appended table and
attachment, Table to
EN/IEC 60065 7
See appended table and
attachment, Table to
EN/IEC 60065 7
th
edition
P
Thin sheet insulation
No thin sheet insulation
N
Basic or supplementary insulation, at least two lay
ers, each meeting 10.3
ers, each meeting 10.3
N
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N
Reinforced insulation, two layers each of which
meet 10.3
meet 10.3
N
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
N
8.9
Adequate insulation between internal hazardous
live conductors and accessible parts
live conductors and accessible parts
Double insulated
P
Adequate insulation between internal hazardous
live parts and conductors connected to accessible
parts
live parts and conductors connected to accessible
parts
Single insulation but safely
anchored
anchored
P
- Page 9 of 32 -
www.nemko.com
Report No. 77024
TRF No: IEC/EN 60065F
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
8.10
Double insulation between conductors connected
to the mains and accessible parts
to the mains and accessible parts
Double insulated, tested
according to 8.9. and 10.3.
according to 8.9. and 10.3.
P
8.11
Detaching of wires
P
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
Primary wires are connected
with multi-contact-housing.
with multi-contact-housing.
P
Vibration
test carried out ........................................ :
See 12.1.2
N
8.12
Adequate cross-sectional area of internal wiring to
mains socket-outlets
mains socket-outlets
Protective fuse (T2.5A/250V)
with 0,82 mm
with 0,82 mm
2
wiring
P
8.13
Adequate fastening of windows, lenses, lamp
covers etc. (pull test 20 N for 10 s)
covers etc. (pull test 20 N for 10 s)
Adequately fastened.
P
8.14
Adequate fastening of covers (pull test 50 N for
10 s)
10 s)
Covers adequately fastened
with screws.
with screws.
P
8.15
No risk of damage to the insulation of internal
wiring due to hot parts or sharp edges
wiring due to hot parts or sharp edges
Wires safely anchored away
from parts with high
temperature.
from parts with high
temperature.
P
8.16
Only special supply equipment can be used
Not supplied by a special
supply apparatus.
supply apparatus.
N
8.17
Insulated winding wire without additional
interleaved insulation
interleaved insulation
No such components
N
8.18
Endurance test as required by 8.17
N
8.19
Disconnection from the mains
See below
P
8.19.1 Disconnect
device
Mains plug is used as
disconnect devices.
disconnect devices.
P
All-pole switch or circuit breaker with >3mm
contact separation
contact separation
No all-pole switch
N
8.19.2
Mains switch ON indication
Indicator lamp or FL display
lit-on
lit-on
P
8.20
Switch not fitted in the mains cord
P
8.21
Bridging components comply with clause 14
Yes, relay across the capacitors
is Certified component.
see appended table, list of
critical components.
is Certified component.
see appended table, list of
critical components.
P
- Page 10 of 32 -
www.nemko.com
Report No. 77024
TRF No: IEC/EN 60065F
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
9.1
Testing on the outside
P
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
No voltages >1000 V ac or
>1500 V dc
>1500 V dc
N
9.1.1.1
Touch current measured from terminal devices
using the network in annex D ................................. :
using the network in annex D ................................. :
See attachment, Table to
EN/IEC 60065 7
EN/IEC 60065 7
th
edition
P
Discharge not exceeding 45 μC
No part or contact of a
terminal with stored voltages
between 60V - 15kV
terminal with stored voltages
between 60V - 15kV
N
Energy of discharge not exceeding 350 mJ
No part or contact of a
terminal with stored voltages
exceeding 15kV
terminal with stored voltages
exceeding 15kV
N
9.1.1.2
Test with test finger and test probe
No access to hazardous live
parts
parts
P
9.1.2
No hazardous live shafts of knobs, handles or
levers
levers
No live shafts, handles or
levers
levers
N
9.1.3
Ventilation holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
No access for the test pin.
P
9.1.4
Terminal devices teste with 1 mm x 20 mm test pin
(10 N); test probe D of IEC 61032
(10 N); test probe D of IEC 61032
Does not reach hazardous live
parts
parts
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
Does not reach hazardous live
parts
parts
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
No pre-set controls
N
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after 2 s :
withdrawal of the mains plug; voltage (V) after 2 s :
See below
N
If C is not greater than 0,1 μF no test needed
< 0,1 μF
P
9.1.7
Enclosure sufficiently resistant to external force
P
Test probe 11 of IEC 61032 for 10 s (50 N)
Test with test finger results in
no hazard.
no hazard.
P
Test hook of fig. 4 for 10 s (20 N)
Test with test hook results in
no hazard.
no hazard.
P
30 mm diameter test tool for 5 s (100 or 250 N) .... :
Tested with 100N results in
no damage.
no damage.
P
9.2
No hazard after removing a cover by hand
No cover removable by hand
N