- Page 7 of 42 - 
 
 
 
 
 Report 
No. 
123035 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
 
Hazardous live terminals ……………………………: 
No hazardous live terminals. 
The output signal will rise to 
28.4Vpeak at maximum output 
power if the speaker output 
load is disconnected. No hazard. 
 
Supply output terminals (other than mains) …...: 
No socket outlet for providing 
power to other apparatus 
N/A 
5.3 
Use of triangle with exclamation mark …………….: 
Correct symbol applied:  
- Imprinted on rear side of the 
  apparatus in connection with 
  CAUTION of opening. 
-  In circuit diagram for critical 
 components. 
5.4 
Instructions for use ………………………….: 
User information in the  
following language: English. 
See comments in Summary 
of Testing. 
5.4.1 
 
a) Mains powered equipment not exposed to 
dripping or splashing. Warning concerning objects 
filled with liquid, etc. ……………………….: 
The user manual includes 
information about danger 
concerning dripping or  
adequate instructions supplied 
splashing and objects filled  
with liquids. 
 
b) Hazardous live terminals, instructions for wiring ...:
No hazardous live terminals 
N/A 
 
c) Instructions for replacing lithium battery …..: 
No lithium battery in the 
equipment. 
N/A 
 
d) Class I earth connection warning ………….: 
Class II apparatus 
N/A 
 
e) Instructions for multimedia system connection …..:
Instructions for multimedia 
system connection provided in 
user manual. 
 
f) Special stability warning for attachment of the 
apparatus to the flor/wall ……………: 
No such equipment 
N/A 
 
g) Warning: battery exposure to heat …………..: 
No battery 
N/A 
 
h) Warning: protective film on CRT face …….: 
No CRT 
N/A 
5.4.2 
Disconnect device: plug/coupler or all-pole mains 
switch location, accessibility and markings ….: 
Plug is regarded as disconnect 
device and is readily operable. 
 
Instructions for permanently connected equipment: 
Not permanently connected  
equipment. 
N/A 
 
Marking, signal lamps or similar for completely 
disconnection from the mains …………..…: 
Information provided in user 
manual. 
 
 
 
- Page 8 of 42 - 
 
 
 
 
 Report 
No. 
123035 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
6 Hazardous 
radiation 
 
6.1 
Ionizing radiation < 36 pA/kg (0,5 mR/h) ………….: 
No ionizing radiation 
N/A 
 
Ionizing radiation under fault condition …………….: 
 
N/A 
6.2 
Laser radiation, emission limits to IEC 60825-1 ….: 
No laser radiation 
N/A 
 
Emission limits under fault conditions ……………..: 
 
N/A 
 
Heating under normal operating conditions 
 
7.1 
Temperature rises not exceeding specified values; 
fuse links and other protective devices defeated …...:
No fuse links operate during 
normal operating condition. 
(see appended table 7.1) 
7.1.1 
Temperature rise of accessible parts ………………..:
(see appended table 7.1) 
7.1.2 
Temperature rise of parts providing electrical 
insulation ……………………………………………..: 
(see appended table 7.1) 
7.1.3 
Temperature rise of parts acting as a support or as a 
mechanical barrier …………………………………..: 
(see appended table 7.1) 
7.1.4 
Temperature rise of windings ………………………: 
(see appended table 7.1) 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
(see appended table 7.1) 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0,2 A at least 150
 o
C : 
See appended table 7.2 for 
mains connector (wafer) 
CN91 and CN92. 
 
Constructional requirements with regard to the protection against electric shock 
 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare ………………………: 
Considered  
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc. ………….:
Operation “By hand” not 
possible 
N/A 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material ………………………..: 
No hygroscopic insulation. 
N/A 
8.4 
No risk of electric shock from accessible parts or 
from parts rendered accessible following the removal 
of a cover which can be removed by hand ……..: 
No live terminals or parts  
removable by hand. 
N/A 
8.5 
Class I equipment …………………...: 
Class II apparatus 
N/A 
 
Basic insulation between hazardous live parts and 
earthed accessible parts ……………………: 
 
N/A 
 
 
- Page 9 of 42 - 
 
 
 
 
 Report 
No. 
123035 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
 
Resistors bridging basic insulation complying with 
14.1 a) ……………………………..: 
No such resistors 
N/A 
 
Capacitors bridging basic insulation complying with 
14.2.1 a) ……………………………….......: 
No such capacitors 
N/A 
 
Protective earthing terminal ………………...: 
 
N/A 
8.6 
Class II equipment and Class II constructions within 
Class I equipment ………………………...: 
Class II apparatus 
 
Double or reinforced insulation between hazardous 
live parts and accessible parts ……………..: 
Double/Reinforced insulation 
complies with requirements 
specified in clause 10 and 13. 
 
Components bridging double or reinforced insulation 
complying with 14.1 a) or 14.3 ………………..: 
The equipment has isolating 
transformers. complies with  
clause 14.3 
 
Basic insulation bridged by components complying 
with 14.3.4.3. ………………………...: 
No such components 
N/A 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.1 a) : 
No such capacitors 
N/A 
 
Double or reinforced insulation being bridged with 2 
capacitors in series complying with 14.2.1 a) : 
No such capacitors 
N/A 
 
Double or reinforced insulation being bridged with a 
single capacitor complying with 14.2.1 b) ……: 
No such capacitors 
N/A 
8.7 
This clause is void ……………………..: 
 
— 
8.8 
Basic or supplementary insulation > 0,4 mm (mm): 
 
N/A 
 
Reinforced insulation > 0,4 mm (mm) ….: 
Main and sub transf. bobbins 
(ref. 14.3) 
 
Thin sheet insulation (excluding non-separable thin 
sheet insulation. See 8.22) …………………: 
No thin sheet insulation 
N/A 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3 …………….....: 
Not used 
N/A 
 
Basic or supplementary insulation, three layers any 
two of which meet 10.3 …………………......: 
Not used 
N/A 
 
Reinforced insulation, two layers each of which meet 
10.3…………………………………...: 
Not used 
N/A 
 
Reinforced insulation, three layers any two which 
meet 10.3 …………………………….: 
Not used 
N/A 
 
 
- Page 10 of 42 - 
 
 
 
 
 Report 
No. 
123035 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
8.9 
Adequate insulation between internal hazardous live 
conductors and accessible parts …………..: 
Double insulated. 
 
Adequate insulation between internal hazardous live 
parts and conductors connected to accessible parts:
Single insulation but safety 
anchored. 
8.10 
Double insulation between conductors connected to 
the mains and accessible parts. …………...: 
Double insulated  
according to 8.9. and 10.3 
Double insulation between internal hazardous live 
parts and conductors connected to accessible 
parts.………………………………………: 
Single insulation but safety 
anchored. 
N/A 
8.11 
Detaching of wires …………………………………..: 
 
N/A 
 
No undue reduction of creepages or clearance 
distances if wires become detached ………………: 
Primary wires are connected 
with multi-contact housing. 
 
Vibration test carried out ………………………: 
See 12.1.2 
N/A 
8.12 
This clause is void ………………………..: 
 
— 
8.13 
Adequate fastening of windows, lenses, lamp covers 
etc. (pull test 20 N for 10 s) ………………...: 
Adequately fastened. 
8.14 
Adequate fastening of covers (push/pull test 50 N for 
10 s) ……………………………………..: 
Covers adequately fastened  
with screws. 
8.15 
No risk of damage to the insulation of internal wiring 
due to hot parts or sharp edges ………………: 
Wires safely anchored away 
from parts with high temperature. 
8.16 
Only special supply equipment can be used …....: 
Not supplied by a special 
supply apparatus. 
N/A 
8.17 
Insulated winding wire without additional interleaved 
insulation ……………………………………………..: 
No such winding wire. 
N/A 
8.18 
Endurance test as required by 8.17 ……….: 
 
N/A 
8.19 
Disconnection from the mains 
See below 
8.19.1 
Disconnect device ……………………...: 
Mains plug is used as 
disconnect devices. 
 
All-pole switch or circuit breaker with >3mm contact 
separation ………………………………: 
No all-pole switch or circuit 
breaker 
N/A 
8.19.2 
Mains switch ON indication …………...: 
Indicator lamp or FL display 
lit-on 
8.20 
Switch not fitted in the mains cord ………: 
 
Page of 80