Harman Kardon AVR 139 (serv.man3) EMC - CB Certificate ▷ View online

 
 
- Page 8 of 10 - 
 
 
 
 
 Report 
No. 
123035 
 
ATTACHMENT 3 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065_I 
15.1.1 
DK: To the first paragraph the following is added: 
In Denmark, supply cords of single phase 
appliances having a rated current not exceeding 13 
A shall be provided with a plug according to the 
Heavy Current Regulations Section 107-2-D1. 
Appliances of CLASS I provided with socket-outlets 
with earth contact or which are intended to be used 
in locations where protection against indirect 
contact is required according to the wiring rules 
shall be provided with a plug in accordance with 
the Heavy Current Regulations Section 107-2-D1 
standard sheet DK 2-1a. 
To the second paragraph the following is added: 
Socket outlets intended for provided power to 
CLASS II apparatus with a rated current of 2.5 A 
shall have the following dimensions: 
 
 
Dimensions in mm 
 
Other dimensions shall be in compliance with the 
Heavy Current Regulations, Section 107-2-D1, 
Standard Sheet DKA 1-3 for portable socket-
outlets. Shutters are not required. 
To the third paragraph the following is added: 
Mains socket-outlets with earthing contact shall be 
in compliance with the Heavy Current Regulations, 
Section 107-2-D1, Standard Sheet DK 1-3a, DK 1-
5a or DK 1-7a. 
Justification
Heavy Current Regulations, Section 107 
Class II apparatus
 
N/A 
15.1.1 
IE: Apparatus which is fitted with a flexible cable or 
cord shall be provided with a 13 A plug in 
accordance with Statutory Instrument 525:97, “13 A  
Plugs and Conversion Adapters for Domestic Use 
Regulations:1997. 
Justification: 
SI 525: 1997 
When marketing in Ireland,  
the apparatus must be 
supplied with a cord and plug 
acceptable in Ireland. 
N/A 
 
 
 
- Page 9 of 10 - 
 
 
 
 
 Report 
No. 
123035 
 
ATTACHMENT 3 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065_I 
15.1.1 
Cont. 
NO: Mains socket-outlets mounted on CLASS II 
apparatus shall comply with the specifications 
given in CEE Publ. 7 as fas as a Applicable, with 
the following amendments: 
§ 8 Dimensions 
a 2.5 A 250 V two-pole socket-outlets for electronic 
apparatus shall comply with the enclosed Standard 
Sheet I. 
 
§ 24 Mechanical strength 
A 2,5 A 250 V socket-outlets for CLASS II 
electronic apparatus are tested as specified in 
12.1.3 of EN 60065. Also the protecting rim shall 
be tested 
Justification: 
Act of 24 May 1929 relating to 
supervision of electrical installation (TEA 1929/FEL 
1998). 
No mains socket- outlets 
N/A 
15.1.1 
UK: Apparatus which is fitted with a flexible cable 
or cord and is designed to be connected to a mains 
socket conforming to BS 1363 by means of that 
flexible cable or cord and plug shall be fitted with 
a ”standard plug” in accordance with Statutory 
Instrument 1768: 1994: The Plugs and Sockets etc. 
(Safety) Regulations 1994, unless exempted by 
those Regulations. 
NOTE ”Standard plug” is defined in SI 1768:1994 
and essentially means an approved plug 
conforming to BS 1363 or an approved conversion 
plug. 
Justification
: SI 1768: 1994 
 
 
 
 
- Page 10 of 10 - 
 
 
 
 
 Report 
No. 
123035 
 
ATTACHMENT 3 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065_I 
J.2 
NO: After Table J.1 the following is added: 
In Norway, due to the IT power distribution system 
used, the a.c. MAINS supply voltage is considered 
to be equal to the line-to-line voltage, and will 
remain 230 V in case of a single earth fault. 
Justification
: Based on a use in Norway of an IT 
power distribution system where the neutral is not 
provided. 
Noted 
 
ZC 
ANNEX ZC TO EN 60065, A-DEVIATIONS (EN) 
 
5.1 
IT: Additional markings on the outside of the TV 
receiver in Italian language 
Not TV set. 
N/A 
 
IT:User instructions in Italian language including a 
conformity declaration 
 
N/A 
 
IT: Certification number on the back cover 
 
N/A 
6.1 
DE: The following requirement applies: 
For the operation of any cathode ray tube intended 
for the display of visual images operating at an 
acceleration voltage exceeding 40 kV, 
authorization is required, or application of type 
approval (Bauartzulassung) and marking. 
Justification
: German ministerial decree against 
ionizing radiation (Röntgenverordnung), in force 
since 2002-07-01, implementing the European 
Directive 96/29/EURATOM.  
NOTE Contact address: 
Physikalisch-Technische Bundesanstalt, 
Bundesallee 100, D-38116 Braunschweig, Tel.: 
Int+49-531-592-6320, Internet: http://www.ptb.de 
No CRT used in the  
equipment. 
N/A 
14 
SE: Switches containing mercury such as 
thermostats, relays and level controllers are not 
allowed. 
Justification
: Ordinance (1990:944) on Prohibition 
in Connection with handling. Importation and 
exportation of Chemical Products (Certain Cases) 
Considered. 
 
 
- Page 1 of 1 - 
 
 
 
 
 Report 
No. 
123035 
 
ATTACHMENT 4 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065_I 
APPENDIX: SINGAPORE DEVIATIONS 
to IEC 60065 7
th
 ed. (2001)  
 
(CB Bulletin No. 105A, May 2003) 
 
Clause 
Requirement – Test 
Result - Remark 
Ver-
dict 
All apparatus must be tested to 230 Vac 
230 Vac tested 
4.3.13 
Apparatus fitted with voltage selector switch must 
be tested as follows: 
Connect apparatus to 230 V ac mains with voltage 
selector switch to settings not suitable for operation 
at 230 V ac. 
No voltage selector. 
N/A 
5.3 
Circuit diagrams must be indicated with component 
values. 
 
 
Circuit diagrams of electronic modules in the 
apparatus must be provided. 
 
7.1, 11.2 
Permissible temperature rises of 10K less than 
those specified in Table 2 are required.  
Meets tropical limits  
10.2 
Humidity treatment.  Adopt the testing conditions 
designed for tropical conditions.  
5 days  
15.1.1 
All Class I apparatus must be fitted with 3-pin mains 
plugs that comply with SS 145/SS 472 that are 
registered with the Safety Authority 
Class II apparatus 
N/A 
 
a) All Class II apparatus must be fitted with 2-pin 
mains plugs (Appendix W) that comply with IEC 
83:1975 (Standard C5, Version II) or EN 50075. 
 
N/A 
 
b) Class II apparatus that are fitted with 3-pin mains 
plugs must use plugs that comply with SS 145 and 
registered with the Safety Authority. 
PSB approved plug provided 
15.3 
Apparatus 
≥ 3 kW must be connected to fixed 
wiring. All connection to fixed wiring must be in 
accordance with Code of Practice CP5. 
< 3 kW 
N/A 
16 
Detachable power cord set must be listed in the test 
report critical component list. 
Not detachable 
N/A 
Misc. 
Apparatus enclosure which is shaped and 
decorated so that it is likely to be treated as a toy 
by children, shall not be accepted for certification 
and registration. 
Not shaped like toy. 
 