- Page 15 of 42 -
Report
No.
123035
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
13.3.2
Circuits conductively connected to the mains comply
with table 8 and, where applicable, table 9 ………..:
with table 8 and, where applicable, table 9 ………..:
(see appended table 13)
P
13.3.3
Circuits not conductively connected to the mains
comply with table 10 ……………………...:
comply with table 10 ……………………...:
No hazardous secondary
voltages.
voltages.
N/A
13.3.4
Measurement of transient voltages …………..:
No measurement of transient
voltages.
voltages.
N/A
13.4
Creepage distances ………………...:
CTI > 100
(see appended table 13)
(see appended table 13)
P
Creepage distances greater than table 11 minimum
values …………………….:
values …………………….:
Not applicable.
N/A
13.5
Printed boards
N/A
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10 …………………………………………:
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10 …………………………………………:
No such PCB used.
N/A
13.5.2
Type B coated printed circuit boards complying with
IEC 60664-3 (basic insulation only) …..:
IEC 60664-3 (basic insulation only) …..:
No type B coated printed
circuit boards.
circuit boards.
N/A
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with 13.3
and 13.4 …………….............:
clearances and creepage distances comply with 13.3
and 13.4 …………….............:
Jointed insulation not applied.
N/A
Conductive parts along reliably cemented joints
comply with 8.8 ……………………:
comply with 8.8 ……………………:
N/A
Temperature cycle test and dielectric strength test :
N/A
13.7
Enclosed, enveloped or hermetically sealed parts not
conductively connected to the mains, clearances and
creepage distances as in table 12 …………:
conductively connected to the mains, clearances and
creepage distances as in table 12 …………:
No enclosed, enveloped or
hermetically sealed parts.
hermetically sealed parts.
N/A
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8 ……………………:
requirements of 8.8 ……………………:
No parts filled with insulating
compound.
compound.
N/A
- Page 16 of 42 -
Report
No.
123035
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
14 Components
14.1 Resistors
N/A
a) Resistors between hazardous live parts and
accessible metal parts ………………:
accessible metal parts ………………:
No such resistors.
N/A
b) Resistors, other than between hazardous live
parts and accessible parts …………………..:
parts and accessible parts …………………..:
Not used.
N/A
Resistors separately approved ………….:
N/A
14.2
Capacitors and RC units
P
Capacitors separately approved …………..……:
Yes, see below
P
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition…:
No Y capacitors
N/A
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition…:
Capacitors C904 and C906,
certified according to
IEC 60384-14, 2
certified according to
IEC 60384-14, 2
nd
edition,
P
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ………:
connected to the mains: tests for X2 ………:
No such capacitors.
N/A
14.2.5
Capacitors with volume exceeding 1750 mm³, where
short-circuit current exceeds 0,2 A: compliance with
IEC60384-1, 4.38 category B or better ……:
short-circuit current exceeds 0,2 A: compliance with
IEC60384-1, 4.38 category B or better ……:
Several E. cap. Vol. >1750mm
3
,
but metal cases.
N/A
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1, 4.38
category B or better …………………:
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1, 4.38
category B or better …………………:
Several E. cap. Vol. >1750mm
3
,
but metal cases.
N/A
Shielded by a barrier acc. to 20.1.4/ table 21 or
metal ………………………….:
metal ………………………….:
N/A
14.3
Inductors and windings
P
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4 …………….:
(as relevant) and clause 20.1.4 …………….:
Transformers evaluated
according to 14.3.3, 14.3.4
and 14.3.5
according to 14.3.3, 14.3.4
and 14.3.5
P
14.3.1
Transformers and inductors marked with
manufacturer's name and type …………….:
manufacturer's name and type …………….:
Adequate marking applied.
Mfr. ID and type no.
Mfr. ID and type no.
P
Transformers and inductors separately approved ….:
No
N/A
14.3.2 General
………………………………:
Isolating transformers
P
Insulation material complies with clause 20.1.4
P
14.3.3
Constructional requirements
P
- Page 17 of 42 -
Report
No.
123035
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
14.3.3.1
Clearances and creepage distances comply with
clause 13 ………………………………..:
clause 13 ………………………………..:
Transformers complied with
clause 13.
clause 13.
P
14.3.3.2
Transformers meet the constructional requirements:
Complied, refer to appended
table 14.3.3.
table 14.3.3.
P
14.3.4
Separation between windings
P
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation) …………………...:
between hazardous live parts and accessible parts
(double or reinforced insulation) …………………...:
Double or reinforced
insulation between primary and
secondary windings according
to clause 8.8.
(see appended table)
insulation between primary and
secondary windings according
to clause 8.8.
(see appended table)
P
Coil formers and partition walls > 0,4 mm …...:
The bobbin fulfils the
requirement of reinforced
insulation; bobbin thickness
> 0.4 mm.
requirement of reinforced
insulation; bobbin thickness
> 0.4 mm.
P
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met ……………………………….:
protective screening only if all 7 conditions of
14.3.4.2 are met ……………………………….:
Class II apparatus.
No such transformer used.
No such transformer used.
N/A
14.3.4.3
Separating transformers with at least basic
insulation:
insulation:
Windings of Class II
construction used.
construction used.
N/A
14.3.5
Insulation between HAZARDOUS LIVE parts and
ACCESSIBLE parts
ACCESSIBLE parts
P
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation) …………………...:
between hazardous live parts and accessible parts
(double or reinforced insulation) …………………...:
Double or reinforced insulation
between hazardous live
windings and accessible
conductive parts.
between hazardous live
windings and accessible
conductive parts.
P
Coil formers and partition walls > 0,4 mm ……...:
The bobbin fulfils the
requirement of reinforced
insulation; bobbin thickness
> 0.4 mm.
requirement of reinforced
insulation; bobbin thickness
> 0.4 mm.
P
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal ………………………………………:
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal ………………………………………:
Windings of Class II
construction used.
construction used.
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity ………………..:
adequate current-carrying capacity ………………..:
N/A
14.4
High voltage components …………………………..:
No high-voltage components
N/A
High-voltage components and assemblies: U > 4 kV
(peak) separately approved …………….....................:
(peak) separately approved …………….....................:
N/A
- Page 18 of 42 -
Report
No.
123035
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
Component meets category V-1 of IEC 60707 …......:
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission ………………………………:
part of the submission ………………………………:
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission ………………………………:
part of the submission ………………………………:
N/A
14.5
Protective devices
P
Protective devices used within their ratings ……:
Thermal link and fuse
P
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened …………………......:
requirement of clause 13 for the voltage across the
device when opened …………………......:
Certified protective devices
applied. See appended table,
list of critical components.
applied. See appended table,
list of critical components.
P
14.5.1.1
a) Thermal cut-outs separately approved ……:
None
N/A
b) Thermal cut-outs tested as part of the submission:
N/A
14.5.1.2
a) Thermal links separately approved ………..:
The thermal link in main transf.
separately approved,
see appended table, list of critical
components
separately approved,
see appended table, list of critical
components
P
b) Thermal links tested as part of the submission .:
N/A
14.5.1.3
Thermal devices re-settable by soldering …………:
No such thermal device.
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127 …………………………….......:
60127 …………………………….......:
Fuse is approved according
to IEC 60127, see appended
table, list of critical components
to IEC 60127, see appended
table, list of critical components
P
14.5.2.2
Correct marking of fuse-links adjacent to holder …:
Marked on PCB adjacent to
fuse as;
fuse as;
F901 : T4A L 250V
P
14.5.2.3
Not possible to connect fuses in parallel ….:
No fuse holder so designed
that fuse-links can be
connected in parallel.
that fuse-links can be
connected in parallel.
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ………..:
replacing fuse-links without the use of a tool ………..:
No replacement of fuse
possible by hand.
possible by hand.
P
14.5.3
PTC-S thermistors comply with IEC 60730-1 ……….:
No PTC’s thermistors.
N/A
PTC-S devices (15 W) category V-1 or better ………:
N/A
14.5.4 Circuit
protectors
have adequate breaking capacity
and their position is correctly marked ……………......:
No such components
N/A
14.6
Switches (see appended table)
N/A