No.
112419
Test item particulars .................................................. :
A/V Surround Receiver
Classification of installation and use ...................... :
Class II
Supply connection .................................................... :
By non-detachable power supply cord
to mains socket.
to mains socket.
Possible test case verdicts:
- test case does not apply to the test object ........... : N/A
- test object does meet the requirement .................. : Pass (P)
- test object does not meet the requirement ........... : Fail (F)
Testing:
Date of receipt of test items ..…….………………….:
July 2008
Date(s) of performance of tests ................................ :
August 2008
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report, a point (coma) is used as the decimal separator.
List of test equipment must be kept on file and available for review.
General product information:
The sample(s) tested complies with the requirements of IEC 60065: 2001 + A1 / EN 60065: 2002 + A1.
Compliance with European Special National Conditions, Annex ZB, and A – Deviations, Annex ZC,
Compliance with European Special National Conditions, Annex ZB, and A – Deviations, Annex ZC,
and
National deviations for Singapore, and recorded at the end of this report.
- Page 7 of 39 -
Report
No.
112419
3 GENERAL
REQUIREMENTS
Safety class of the apparatus ................................. :
Class II apparatus.
P
4
GENERAL CONDITIONS OF TESTS
4.1.4
Ventilation instructions require the use of the test box
No test box required.
Tested according to
manufacturers instructions
Tested according to
manufacturers instructions
P
5 MARKING
Comprehensible and easily discernible
On front and rear side of the
enclosure
enclosure
P
Permanent durability against water and petroleum spirit
Tested with water / sprit
P
5.1 Identification,
maker, model .................................... :
Maker: harman / kardon
Model: AVR 137/230 or
Model: AVR 137/230 or
AVR 138/230
See copy of marking plate.
P
Class II symbol if applicable
Class II symbol is applied in
according to IEC 60417-5172.
according to IEC 60417-5172.
P
Rated supply voltage and symbol ........................... :
AC-symbol (
~
) with 230V
marked
P
Frequency if safety dependant
50Hz
P
Rated current or power consumption ..................... :
235W
P
5.2 Earth
terminal
Class II apparatus
N/A
Hazardous live terminals
No hazardous live terminals
The output signal will rise to
28Vpeak at maximum out
power if the speaker output load
is disconnected, no hazard
The output signal will rise to
28Vpeak at maximum out
power if the speaker output load
is disconnected, no hazard
.
P
Supply output terminals (other than mains)
No socket outlet for providing
power to other apparatus
power to other apparatus
N/A
5.3
Use of triangle with exclamation mark
Correct symbol applied:
Imprinted on rear side in
connection with CAUTION of
opening. Further; no incorrect
use of this symbol is found
Imprinted on rear side in
connection with CAUTION of
opening. Further; no incorrect
use of this symbol is found
P
- Page 8 of 39 -
Report
No.
112419
5.4
Instructions for use
User information in the following
language: English.
See comments in summary of
testing
language: English.
See comments in summary of
testing
P
5.4.1
Mains powered equipment not exposed to dripping or
splashing. Warning concerning objects filled with
liquid, etc.
splashing. Warning concerning objects filled with
liquid, etc.
The user manual includes
information about danger
concerning dripping or splashing
and objects filled with liquids.
information about danger
concerning dripping or splashing
and objects filled with liquids.
P
Hazardous live terminals, instructions for wiring
No hazardous live terminals
N/A
Instructions for replacing lithium battery
Not used lithium battery.
N/A
Instructions for modem if fitted
No modem used
N/A
Class I earth connection warning
Class II apparatus
N/A
Instructions for multimedia system connection
Not applicable
N/A
Special stability warning for fixed installation
Not for fixed installation
N/A
Warning: battery exposure to heat
No battery
N/A
Warning: protective film on CRT face
No CRT
N/A
5.4.2
Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings
switch location, accessibility and markings
Plug is regarded as
disconnect device and is
readily operable.
disconnect device and is
readily operable.
P
Instructions for permanently connected equipment
Not permanent connected
equipment
equipment
N/A
6 HAZARDOUS
RADIATION
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No ionizing radiation.
N/A
6.1
EN 60065
European Council Directive 96/29/Euratom of 13 May
1996 10cm from outer surface of apparatus <1µSv/h
(0,1mR/h)
1996 10cm from outer surface of apparatus <1µSv/h
(0,1mR/h)
N/A
6.2
Laser radiation, emission limits to IEC 60825-1 ..... :
No laser
N/A
Emission limits under fault conditions ..................... :
N/A
- Page 9 of 39 -
Report
No.
112419
7
HEATING UNDER NORMAL OPERATING CONDITIONS
7.1
Temperature rises not exceeding specified values, no
operation of fuse links
operation of fuse links
No fuse links operate during
normal operating operation.
(see appended table)
normal operating operation.
(see appended table)
P
7.1.1
Temperature rise of accessible parts
(see appended table)
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table)
P
7.1.3
Temperature rise of parts acting as a support or as a
mechanical barrier
mechanical barrier
(see appended table)
P
7.1.4
Temperature rise of windings
(see appended table)
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table)
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the mains
carrying a current > 0,2 A at least 150
supporting parts conductively connected to the mains
carrying a current > 0,2 A at least 150
o
C
Approved components
according to relevant IEC
standards.
according to relevant IEC
standards.
N/A
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
AGAINST ELECTRIC SHOCK
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
Considered
P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
No changing voltage setting
device
device
N/A
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
No hygroscopic materials
used
used
N/A
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
cover which can be removed by hand
No cover removable by hand
N/A
8.5
Class I equipment
Class II apparatus
N/A
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N/A
Resistors bridging basic insulation complying with
14.1 a)
14.1 a)
N/A
8.6
Class II equipment and Class II constructions within
Class I equipment
Class I equipment
Class II apparatus
P
Reinforced or double insulation between hazardous
live parts and accessible parts
live parts and accessible parts
Double/Reinforced insulation
complies with requirements
specified in clause 10 and 13.
complies with requirements
specified in clause 10 and 13.
P