- Page 6 of 39 - 
 
 
 
 Report 
No. 
112419 
 
 
Test item particulars ..................................................  :
A/V Surround Receiver 
Classification of installation and use ...................... :
Class II
 
Supply connection  .................................................... :
By non-detachable power supply cord 
to mains socket.
 
Possible test case verdicts: 
 
- test case does not apply to the test object ........... : N/A 
- test object does meet the requirement .................. : Pass  (P) 
- test object does not meet the requirement ........... : Fail  (F) 
Testing:  
Date of receipt of test items ..…….………………….:
July 2008 
Date(s) of performance of tests ................................ :
August 2008 
General remarks: 
The test results presented in this report relate only to the object tested. 
This report shall not be reproduced, except in full, without the written approval of the Issuing testing 
laboratory. 
"(see Enclosure #)" refers to additional information appended to the report. 
"(see appended table)" refers to a table appended to the report. 
 
Throughout this report, a point (coma) is used as the decimal separator. 
List of test equipment must be kept on file and available for review. 
General product information:  
 
The sample(s) tested complies with the requirements of IEC 60065: 2001 + A1 / EN 60065: 2002 + A1. 
Compliance with European Special National Conditions, Annex ZB, and A – Deviations, Annex ZC, 
and 
National deviations for Singapore, and recorded at the end of this report.
 
 
 
 
 
 
 
 
 
 
 
- Page 7 of 39 - 
 
 
 
 Report 
No. 
112419
 
 
 
 
3 GENERAL 
REQUIREMENTS 
 
 
Safety class of the apparatus  ................................. : 
Class II apparatus. 
 
 
 
GENERAL CONDITIONS OF TESTS 
 
4.1.4 
Ventilation instructions require the use of the test box
No test box required.  
Tested according to  
manufacturers instructions
 
 
 
 
5 MARKING 
 
 
Comprehensible and easily discernible 
On front and rear side of the  
enclosure 
 
Permanent durability against water and petroleum spirit 
Tested with water / sprit 
5.1 Identification, 
maker, model  .................................... : 
Maker:  harman / kardon 
Model:  AVR 137/230 or  
  
 AVR 138/230 
See copy of marking plate.
 
 
Class II symbol if applicable 
Class II symbol is applied in 
according to IEC 60417-5172. 
 
Rated supply voltage and symbol  ........................... : 
AC-symbol ( 
~
 )  with 230V 
marked 
 
Frequency if safety dependant 
50Hz 
 
Rated current or power consumption  ..................... : 
235W 
5.2 Earth 
terminal 
Class II apparatus 
N/A 
 
Hazardous live terminals 
No hazardous live terminals 
The output signal will rise to 
28Vpeak at maximum out  
power if the speaker output load 
is disconnected, no hazard
.
 
 
Supply output terminals (other than mains) 
No socket outlet for providing 
power to other apparatus
 
N/A 
5.3 
Use of triangle with exclamation mark 
Correct symbol applied: 
Imprinted on rear side in  
connection with CAUTION of 
opening. Further; no incorrect 
use of this symbol is found 
 
 
- Page 8 of 39 - 
 
 
 
 Report 
No. 
112419
 
 
 
 
5.4 
Instructions for use 
User information in the following 
language: English.  
See comments in summary of 
testing
 
5.4.1 
Mains powered equipment not exposed to dripping or 
splashing. Warning concerning objects filled with 
liquid, etc. 
The user manual includes 
information about danger 
concerning dripping or splashing 
and objects filled with liquids. 
 
Hazardous live terminals, instructions for wiring 
No hazardous live terminals 
N/A 
 
Instructions for replacing lithium battery 
Not used lithium battery. 
N/A 
 
Instructions for modem if fitted 
No modem used 
N/A 
 
Class I earth connection warning 
Class II apparatus 
N/A 
 
Instructions for multimedia system connection 
Not applicable
 
N/A 
 
Special stability warning for fixed installation 
Not for fixed installation
 
N/A 
 
Warning: battery exposure to heat 
No battery 
N/A 
 
Warning: protective film on CRT face 
No CRT 
N/A 
5.4.2 
Disconnect device: plug/coupler or all-pole mains 
switch location, accessibility and markings 
Plug is regarded as 
disconnect device and is 
readily operable. 
 
Instructions for permanently connected equipment 
Not permanent connected 
equipment 
N/A 
 
 
 
 
6 HAZARDOUS 
RADIATION 
 
6.1 
Ionizing radiation < 36 pA/kg (0,5 mR/h) 
No ionizing radiation. 
N/A 
6.1 
EN 60065 
European Council Directive 96/29/Euratom of 13 May 
1996 10cm from outer surface of apparatus <1µSv/h 
(0,1mR/h) 
 
N/A 
6.2 
Laser radiation, emission limits to IEC 60825-1  ..... : 
No laser  
N/A 
 
Emission limits under fault conditions ..................... : 
 
N/A 
 
 
- Page 9 of 39 - 
 
 
 
 Report 
No. 
112419
 
 
 
 
HEATING UNDER NORMAL OPERATING CONDITIONS 
 
7.1 
Temperature rises not exceeding specified values, no 
operation of fuse links 
No fuse links operate during 
normal operating operation. 
(see appended table) 
7.1.1 
Temperature rise of accessible parts 
(see appended table) 
7.1.2 
Temperature rise of parts providing electrical 
insulation 
(see appended table) 
7.1.3 
Temperature rise of parts acting as a support or as a 
mechanical barrier 
(see appended table) 
7.1.4 
Temperature rise of windings 
(see appended table) 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
(see appended table) 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the mains 
carrying a current > 0,2 A at least 150
 o
Approved components 
according to relevant IEC  
standards.
 
N/A 
 
 
 
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION 
AGAINST ELECTRIC SHOCK 
 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare 
Considered 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc. 
No changing voltage setting  
device
 
N/A 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material 
No hygroscopic materials 
used 
N/A 
8.4 
No risk of electric shock following the removal of a 
cover which can be removed by hand 
No cover removable by hand 
N/A 
8.5 
Class I equipment 
Class II apparatus 
N/A 
 
Basic insulation between hazardous live parts and 
earthed accessible parts 
 
N/A 
 
Resistors bridging basic insulation complying with 
14.1 a) 
 
N/A 
8.6 
Class II equipment and Class II constructions within 
Class I equipment 
Class II apparatus 
 
Reinforced or double insulation between hazardous 
live parts and accessible parts 
Double/Reinforced insulation 
complies with requirements 
specified in clause 10 and 13. 
Page of 57