Harman Kardon AVR 135 EMC - CB Certificate ▷ View online
- APPENDIX CENELEC EN60065:1998 TO IEC60065:1998 -
- Page 2 of 3 -
Order
No.
34019
15.2 C
Delete note 2
16.1 C
Delete note 1
16.2 C
Delete the note
20 C
Delete note 2
APPENDIX
ANNEX B (normative)
No TNV circuit
N
Annex B C
Delete note 2
B.5.4.1 S
(NO) Marking stating that the
apparatus must be connected to an
earthed mains socket outlet.
Applicable text is:
"Apparatet må kun tilkoples jordet
stikkontakt" or
"Jordet stikkontakt skal benyttes når
apparatet tilkoples datanett"
Swedish text can also be accepted.
apparatus must be connected to an
earthed mains socket outlet.
Applicable text is:
"Apparatet må kun tilkoples jordet
stikkontakt" or
"Jordet stikkontakt skal benyttes når
apparatet tilkoples datanett"
Swedish text can also be accepted.
B.5.4.1 S
(SE) Marking stating that the
apparatus must be connected to an
earthed mains socket outlet.
The marking text shall be in Swedish
and as follows:
"Apparaten skall anslutas till jordat
uttag när den ansluts till ett nätverk"
apparatus must be connected to an
earthed mains socket outlet.
The marking text shall be in Swedish
and as follows:
"Apparaten skall anslutas till jordat
uttag när den ansluts till ett nätverk"
B.5.4.1 e) C
Delete notes 1 and 2
B.8.1 C
Delete notes 1, 2 and 3
B.8.1 S
(DK) Method b) is permitted only for
PERMANENTLY CONNECTED
APPARATUS
PERMANENTLY CONNECTED
APPARATUS
B.8.1 S
(NO) Method b) is not permitted
B.8.2 C
Delete the note
B.14.12 C
Delete notes 1 and 2
B.14.12 S
(DK) The following note is added:
NOTE in Denmark the use of surge
suppressors between the
TELECOMMUNICATION
NETWORK and conductive
ACCESSIBLE parts or TERMINALS
which are considered to be
ACCESSIBLE, is allowed only for
PERMANENTLY CONNECTED
APPARATUS.
NOTE in Denmark the use of surge
suppressors between the
TELECOMMUNICATION
NETWORK and conductive
ACCESSIBLE parts or TERMINALS
which are considered to be
ACCESSIBLE, is allowed only for
PERMANENTLY CONNECTED
APPARATUS.
- APPENDIX CENELEC EN60065:1998 TO IEC60065:1998 -
- Page 3 of 3 -
Order
No.
34019
B.14.12 S
(NO) The following note is added:
NOTE in Norway, for Class I apparatus
intended to be connected to the MAINS
by means of a plug, surge suppressors
may only be connected between TNV
circuits and ACCESSIBLE parts if the
apparatus has a marking stating that it
must be connected to an earthed
MAINS socket outlet.
NOTE in Norway, for Class I apparatus
intended to be connected to the MAINS
by means of a plug, surge suppressors
may only be connected between TNV
circuits and ACCESSIBLE parts if the
apparatus has a marking stating that it
must be connected to an earthed
MAINS socket outlet.
B.14.12 S
(SE) The following note is added:
NOTE in Sweden, for Class I apparatus
intended to be connected to the MAINS
by means of a plug, surge suppressors
may only be connected between TNV
circuits and ACCESSIBLE parts if the
apparatus has a marking stating that it
must be connected to an earthed
MAINS socket outlet.
The marking text shall be in Swedish
and as follows:
"Apparaten skall anslutas till jordat
uttag."
NOTE in Sweden, for Class I apparatus
intended to be connected to the MAINS
by means of a plug, surge suppressors
may only be connected between TNV
circuits and ACCESSIBLE parts if the
apparatus has a marking stating that it
must be connected to an earthed
MAINS socket outlet.
The marking text shall be in Swedish
and as follows:
"Apparaten skall anslutas till jordat
uttag."
APPENDIX
ANNEX G (normative)
Annex G C
Delete the note
APPENDIX
ANNEX P (informative)
Annex P C
Add the following notes for the
standards indicated :
standards indicated :
IEC 60130 :
NOTE: IEC 60130-9:1989 + A1:1993
are harmonized as EN 60130-9 (not
modified).
IEC 60169 :
NOTE: Parts 23, 24 and 25 are
harmonized as Ens (not modified).
IEC 60173 :
NOTE: Harmonized as HD 27 S1:1983
(not modified).
IEC 60260 :
NOTE: Harmonized as HD 98 S1:1977
(not modified).
IEC 60335-2-56 :
NOTE: Harmonized as EN 60335-2-56:
1997 (not modified).
IEC 61040 :
NOTE: Harmonized as EN 61040:
1992 (not modified).
IEC 60695 :
NOTE: Harmonized as EN 60695
series (not modified).
NOTE: IEC 60130-9:1989 + A1:1993
are harmonized as EN 60130-9 (not
modified).
IEC 60169 :
NOTE: Parts 23, 24 and 25 are
harmonized as Ens (not modified).
IEC 60173 :
NOTE: Harmonized as HD 27 S1:1983
(not modified).
IEC 60260 :
NOTE: Harmonized as HD 98 S1:1977
(not modified).
IEC 60335-2-56 :
NOTE: Harmonized as EN 60335-2-56:
1997 (not modified).
IEC 61040 :
NOTE: Harmonized as EN 61040:
1992 (not modified).
IEC 60695 :
NOTE: Harmonized as EN 60695
series (not modified).
- IEC 60065, 6
th
edition (1998) -
- Page 1 of 1 -
Order No.
34019
APPENDIX: SINGAPORE DEVIATIONS
to IEC 60065 6
th
ed. (1998)
Test results according to SS143: 2000
Clause
Requirement - Test
Result - Remark
Ver-
dict
15.1.1
Add to NOTE 1:
13A plugs and sockets-outlets are prescribed
articles in Singapore and compliance to SS
145 is required. SS 145 is the specification for
13A plugs and socket-outlets.
articles in Singapore and compliance to SS
145 is required. SS 145 is the specification for
13A plugs and socket-outlets.
Must be considered before marketing in
Singapore.
Singapore.
N
Information
Attention is also drawn to the following:
Where the reference “This International
Standard” appears, it should be interpreted as
“This SS 143”.
Standard” appears, it should be interpreted as
“This SS 143”.
The comma has been used throughout as an
decimal marker in IEC60065, whereas in
Singapore Standards it is a practice to use a
full-point on the baseline as a decimal maker.
decimal marker in IEC60065, whereas in
Singapore Standards it is a practice to use a
full-point on the baseline as a decimal maker.
Considered
P
References to International Standards to be
replaced by equivalent Singapore Standards
as follows:
replaced by equivalent Singapore Standards
as follows:
International Standard
Singapore Standard
IEC 60227
SS 358
IEC 60335-1: 1991
SS 146 Part 1: 1994
IEC 60529
SS IEC 529: 1989
IEC60950: 1991
SS 337: 1997
IEC 61058-1: 1996
SS 144 Part 1: 1997
Considered
P
Issue Nemko 2002-10
- Page 1 of 3 -
PHOTOS
Order No.
34019
Click on the first or last page to see other AVR 135 service manuals if exist.