Harman Kardon AVR 135 EMC - CB Certificate ▷ View online

 - 
IEC 60065, 6th edition : 1998
 - 
- Page 20 of 38 - 
 
 
   
 Order 
No. 
34019
 
 
 
 
14.3.3-5 Transformer 
construction 
See below. 
 
14.3.3.2 
Transformers meet the constructional 
requirements : 
See below. 
 
Transformer/motor Insulation 
Insulation Test 
Flashover 
Creepage 
distances 
Part No/markings 
between 
resistance voltage  Breakdown
and 
clearances 
 
 
  M Ohm 
kV(60)s 
voltage kV 
Measured 
Required  
KLT5V037ZE 
Pr - sec 
> 100 
3KV (rms) 
10,2 mm 
 6 mm   
 
Pr - ic 
> 100 
3KV (rms) 
8,8 mm 
 6 mm   
 
 
 
 
 
 
 
KLT5J033ZE 
Pr – sec 
> 100 
3KV (rms) 
7,5 mm 
 6 mm   
 
Pr - ic 
> 100 
3KV (rms) 
6,5 mm 
 6 mm   
 
 
 
 
 
 
 
 
Components / construction   
(Main transformer) 
 
Windings on two separate bobbins. The bobbins are 
placed in an insulating housing with two 
compartments, one above the other. Bobbin thickness: 
> 0,4mm. 
 
Components / construction 
(Sub transformer)
   
Windings on single bobbins. Center wall provided 
between primary and secondary windings. Satisfactory 
constructed. Bobbin thickness: > 0,4mm. 
Transformer/motor Insulation Thickness 
(mm) 
Material 
Dielectric strength test 
Part No/markings 
between 
      X 
 
for each combination of 
 
 
    Number 
 
two (2) layers  
KLT5V037ZE 
Pr - sec 
0,80 mm min. x 1 
PETP bobbin 
1 layer tested – Pass    *) 
 
Pr - ic 
0,80 mm min. x 1 
PETP bobbin 
1 layer tested – Pass    *) 
 
 
 
 
 
KLT5J033ZE 
Pr - sec 
0,50 mm min. x 2 
0,50 mm min. x 1 
PETP bobbin wall 
PBT bobbin cap. 
1 layer tested – Pass    *) 
 
Pr - ic 
0,60 mm min. x 1 
PETP bobbin 
1 layer tested – Pass    *) 
 
Pr - ic 
0,50 mm min. x 1 
PBT bobbin cap. 
1 layer tested – Pass    *) 
 
 
 
 
 
*) Test voltage: 3000 Vrms. 
14.3.4.1 
Class II transformers have adequate 
separation between hazardous live 
windings and windings intended to 
be connected to accessible 
conductive parts (double or 
reinforced insulation)   
Double or reinforced insulation between primary and 
secondary windings according to clause 8.8. 
 
 
Coil formers and partition walls 
≥ 0,4 mm   
The bobbin fulfils the requirement of reinforced insulation, 
thickness: 
≥ 0,4 mm. 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 21 of 38 - 
 
 
   
 Order 
No. 
34019
 
 
 
 
14.3.4.2 
Class I transformers, with basic 
insulation and protective screening 
only if all 7 conditions of 14.3.4.2 are 
met  
 
14.3.4.3 
Separating transformers with at least 
basic insulation   
 
14.3.5.1 
Class II transformers have adequate 
insulation between hazardous live 
parts and accessible parts (double 
or reinforced insulation)   
Double or reinforced insulation between hazardous live 
windings and accessible conductive parts. 
 
Coil formers and partition walls 
≥ 0,4 mm   
The bobbin fulfils the requirement of reinforced insulation, 
thickness: 
≥ 0,4 mm. 
14.3.5.2 
Class I transformers have adequate 
insulation between hazardous live 
parts and accessible conductive 
parts or those conductive parts or 
protective screens connected to a 
protective earth terminal   
 
 
Winding wires connected to 
protective earth have adequate 
current-carrying capacity   
 
14.4 
High voltage components 
 
 
 
High-voltage components and 
assemblies: U > 4 kV (peak) 
separately approved   
No high voltage components used 
 
 
Component meets category FV 1 of 
IEC 60 707   
 
14.4.1 
High voltage transformers and 
multipliers tested as part of the 
submission  
 
14.5 Protective 
devices 
 
 
 
Protective devices used within their 
ratings  
Yes,  
Thermal link and fuse 
 
External clearance and creepage 
distances appropriate for the voltage 
across the device when opened   
Adequate external clearance and creepage distance 
14.5.1.1 
a) Thermal cut-outs separately 
approved  
None 
 
 
b) Thermal cut-outs tested as part of 
the submission   
 
14.5.1.2 
a) Thermal links separately 
approved  
Manufacturer / type: 
Sub transformer -    Uchihashi Estec / 423 
Main transformer -  Anzen Dengu Co / L8 
Certified by: VDE according to IEC60691 
 
b) Thermal links tested as part of the 
apparatus  
 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 22 of 38 - 
 
 
   
 Order 
No. 
34019
 
 
 
 
14.5.1.3 
Thermal devices resettable by 
soldering  
No such thermal device 
14.5.2.1 
Fuse-links in the mains circuit 
according to IEC 60 127   
See list below 
Circuit Manufacturer 
Dimen- 
Approved
Marking of 
Marking 
Current 
diagram 
 
sions 
by 
rated current, 
close to 
through 
informa- 
 
 
 
pre-arcing time 
the com- 
the fuse   
tion 
 
 
 
and current 
ponent 
in normal 
Part No 
 
 
 
characteristic 
 
operation   
F901, F902 
Littelfuse 
8.5
φ 
VDE 
T 2.5A 250V 
T 2.5A L 250V  < 0,50 A 
F903, F904 
F905, F906 
Orisel Co. Ltd. 
5
×20 mm 
VDE 
T 6.3A L 250V 
T 6.3A L 250V  2,33 A 
F907 
Orisel Co. Ltd. 
5
×20 mm 
VDE 
T 4A L 250V 
T 4A L 250V 
1,45 A 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
14.5.2.2 
Correct marking of fuse-links 
adjacent to holder      
Correct marking applied close to the fuse, see table 
above. 
14.5.2.3 
Not possible to connect fuses in 
parallel    
No fuse holder so designed that fuse-links can be 
connected in parallel 
14.5.2.4 
Not possible to touch hazardous live 
parts when replacing fuse-links 
without the use of a tool      
No replacement of fuse possible by hand. 
 
14.5.3 
PTC-S thermistors comply with 
IEC 60 738   
No PTC’s 
 
PTC-S devices (>15 W) category 
FV 1 or better   
 
14.5.4 
Other protective devises. 
Circuit protectors have adequate 
breaking capacity and their position 
is correctly marked   
No other protective devices 
14.6 Switches 
 
 
 
Manually operated mechanical 
switch (MOMS) conductively 
connected to the mains
 
 
 
Part No 
Function 
Manufacturer 
Type 
Rated 
Marking 
 All- 
One 
Name 
Trademark 
 
Surge 
 pole 
pole 
 
 
 
  
current 
 
 
 
 
 
 
 
 
 
SW1   x POSTEC 
Electric. 
SDL1P-B 
250  5 
80A 
RY94   x  Tyco 
Electronics 
OEG 
SDT-S-112DMR 
250  8 
120A 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 23 of 38 - 
 
 
   
 Order 
No. 
34019
 
 
 
 
14.6.1 
Permanently connected equipment 
provided with an all-pole mains 
switch unless 5.4.2 is met   
Apparatus is not permanently connected 
 
14.6.2 
Manually operated mechanical 
switch (MOMS), required where 
power consumption > 15 W and/or 
peak voltage > 4 kV 
Yes. MOMS required. See table above. 
 
 
Switch readily accessible and not in 
mains cord   
Switch located on the front and readily accessible 
 
 
Exception for automatic switching   
 
 
Exception for continuous operation   
 
14.6.3 
Manually operated mechanical 
switch (MOMS): Switch indication / 
On position clearly discernible   
The display is illuminated. 
 
 
Indication by marking meets Cl. 5   
Yes 
 
Indication of the OFF position   
Off-position marked with “OFF” 
14.6.4 
Manually operated mechanical 
switch (MOMS) fitted. Is there a 
Stand-by mode      
Yes 
 
 
Stand-by mode clearly discernible    
LED indication 
 
Exception for low Stand-by current 
< 0,7 mA (peak)   
 
14.6.5 
Components bridging contacts of 
mains switches comply with 14.1 a) 
or 14.2.2   
Yes,  
Switch for C853, and relay for C904. 
See also clause 14.2. 
14.6.6.a. 
Manually operated mechanical 
switches (MOMS) separately 
approved to IEC 61 058-1   
Yes.  
- Mains switch, certified by VDE, 
- Mains relay, certified by SEMKO. 
14.6.6.b. 
Manually operated mechanical 
switch (MOMS) tested as part of the 
equipment complies with 14.6.7, 
14.6.10 and 20.1.4 and meets 
14.6.8 and/or 14.6.9 and Annex G 
(G1.1)  
 
 
Flame test for mains switches   
 
14.6.7 Endurance 
test 
Switch and Relay, separately certified. 
14.6.8 
Temperature rise in mains switch 
Switch and Relay 
14.6.9 
Dielectric strength test 
Switch and Relay 
14.6.10 
Surge current for mains switches 
also controlling mains socket-outlets
Measured mains relay / switch surge current  : 33A 
Socket-outlet through current (50W) 
: 20A 
Mains switch / relay controlling total current 
: 53A 
 
The measured surge current value is less than rated 
surge current rating of the mains relay and switch. OK. 
Ref. clause 7. 
Page of 51