DOWNLOAD Harman Kardon AVR 135 Service Manual ↓ Size: 2.36 MB | Pages: 51 in PDF or view online for FREE

Model
AVR 135
Pages
51
Size
2.36 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-135.pdf
Date

Harman Kardon AVR 135 EMC - CB Certificate ▷ View online

 - 
IEC 60065, 6th edition : 1998
 - 
- Page 32 of 38 - 
 
 
   
 Order 
No. 
34019
 
 
 
 
ANNEX A, ADDITIONAL 
REQUIREMENTS FOR 
APPARATUS WITH PROTECTION 
AGAINST SPLASHING WATER   
Not intended for outdoor use. 
A.5.1 
j) Marked with IPX4 (IEC 60 529), 
5.4.1 a) does not apply   
 
A.10.2.1 
Enclosure provides protection 
against splashing water   
 
A.10.2.2 
Humidity treatment carried out for 
7 days   
 
 
ANNEX B, APPARATUS TO BE 
CONNECTED TO THE 
TELECOMMUNICATION 
NETWORKS  
Not intended for telecommunication networks 
B.5.4.1 
e) Where the separation of TNV 
circuits from other circuits relies on 
protective earthing the instructions 
make it clear that protective earthing 
is essential   
 
B.8.1 
TNV circuits separated from the 
mains circuit and from hazardous 
live parts by either: 
 
 
 
a) double or reinforced insulation   
 
 
b) basic insulation with earthed 
protective screening   
 
B.8.2 
TNV circuits separated from circuits 
other than those in B.8.1 and from 
accessible conductive parts by basic 
insulation meeting the requirements 
for clearances and creepage 
distances for the voltages concerned 
 
B.9.1.1 
TNV circuit terminals contacts which 
cannot be touched by probe B.1, 
exempt from the requirements 
inaccessible terminal contacts in 
9.1.1  
 
B.10.1 
Insulation between TNV terminals 
and antenna terminals (including 
interconnection terminals which may 
be connected to equipment with 
antenna terminals) withstands the 
50 discharges of 10.1   
 
B.14.12 
Surge suppressors between TNV 
circuits and other parts of the 
equipment have breakdown voltage 
at least 1,8 times the mains voltage 
 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 33 of 38 - 
 
 
   
 Order 
No. 
34019
 
 
 
 
 
LIST OF CRITICAL COMPONENTS 
 
Part No 
Component/ 
Object 
Manufacturer 
Type / Model 
Ratings / 
Technical Data 
Complies 
with the 
following 
standard 
Marks of 
conformity 
granted ** 
For 
CENELEC 
Countries 
Mains plug   
with cord   
Kenic Electric Mfg. 
KE-21 
H03VVH2-F 
2.5A/250V 
6A/250V  
IEC60884-1
VDE 
 
alt. 
Kenic Electric Mfg. 
KE-32 
H03VVH2-F 
2.5A/250V 
6A/250V  
IEC60884-1
VDE 
 
alt. Phino 
Electrical 
Wire & Cable 
PHP-205 
H03VVH2-F 
2.5A/250V 
6A/250V  
IEC60884-1
VDE 
 
alt. 
Kuk Je Tong shin 
KKJ-1004A 
H03VVH2-F 
2.5A/250V 
6A/250V  
IEC60884-1
VDE 
 
alt. 
Volex (Asia) Pte. 
Ltd. 
M4206 
H03VVH2-F 
2.5A/250V 
6A/250V  
IEC60884-1
VDE 
 
alt. 
HWAJIN KDK Co. 
KKP-419C 
H03VVH2-F 
2.5A/250V 
6A/250V  
IEC60884-1
VDE 
For U.K. 
Mains plug 
with cord 
PHINO Electronics 
Co., Ltd 
PHP-307F 
H03VVH2-F 
13A/250V 
6A/250V  
BS1363 
BS6500 
BSI 
 
alt. 
Volex (Asia) Pte Ltd.
MP5004A 
H03VVH2-F 
13A/250V 
6A/250V  
BS1363 
BS6500 
BSI 
 
alt. 
Volex (Asia) Pte Ltd.
MP5005 
H03VVH2-F 
13A/250V 
6A/250V  
BS1363 
BS6500 
BSI 
 
alt. 
Winbo Industries 
MS 323N 
H03VVH2-F 
13A/250V 
6A/250V  
BS1363 
BS6500 
BSI 
 
alt. Luen 
Tai 
(IP’S)
 Elect.
Kenic Electric Mfg. 
9518 
H03VVH2-F 
13A/250V 
6A/250V  
BS1363 
BS6500 
BSI 
 
alt. 
Well Shin Enterprise 
Co. Ltd. 
WS-012A 
H03VVH2-F 
13A/250V 
6A/250V  
BS1363 
BS6500 
BSI 
OL91 Mains 
Socket-outlet 
Dae Ryung 
Electronics. 
A3-04-D007 2.5A/250V  IEC60884-1
NEMKO 
 
Main transf. 
 
 
Bobbin Mtl. 
 
Thermal fuse
 
Seoul Electronics & 
Telecom Co., Ltd.   
 
Wintech Polymer Ltd.
 
Anzen Dengu Co.Ltd
KLT5V037ZE / 
CLT5V037ZE
 
 
CN9030 
 
L8
 
230V, Class B 
 
 
V-0, 155°C 
 
5A/250V, 169℃
 
IEC60065 
clause 14.3 
 
UL94 
   
IEC60691
 
1.) 
 
 
UL, 
E2131445
 
VDE
 
**) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively 
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 6.Edition : 1998 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 34 of 38 - 
 
 
   
 Order 
No. 
34019
 
 
 
 
 
LIST OF CRITICAL COMPONENTS (continued) 
 
Part No 
Component/ 
Object 
Manufacturer 
Type / Model 
Ratings / 
Technical Data 
Complies 
with the 
following 
standard 
Marks of 
conformity 
granted ** 
 
Sub 
transformer 
 
Bobbin Mtl. 
alt. 
alt. 
 
Thermal fuse 
Seoul Electronics & 
Telecom Co., Ltd. 
 
EI 
DUPONT.
 
Wintech Polymer Ltd.
Samyang Co. 
 
Uchihashi Estec Co.
KLT5J033ZE / 
CLT5J033ZE 
 
FR530  
CN9030 
2550GN30 
 
423 
230V, Class E 
 
 
V-0, 155°C 
V-0, 155°C 
V-0, 140°C 
 
0.5A/250V 130 
°C
 
IEC60065 
clause 14.3
 
UL94 
UL94 
UL94 
 
IEC60691 
1.) 
 
 
UL, 
E69578 
UL, 
E2131445
UL, 
E121254
 
 
VDE 
SW1 
Mains switch 
POSTEC Electric. SDL1P-B 
5A/80A 
250V IEC60065
 
IEC61058-
1
 
VDE 
RY94 
Mains relay 
Tyco Electronics 
SDT-S-112DMR
8A/120A 250V 
IEC60065 
IEC61058-
SEMKO 
F901, F902 
Outlet fuse 
alt. 
alt. 
Littelfuse B.V. 
Bel Fuse. 
Save Fusetech. 
0663 
MRT 
SR-5 
T2.5A 250V 
IEC60127 
VDE 
VDE 
VDE 
F903, F904 
F905, F906 
Sec. fuse 
alt. 
alt. 
alt. 
Orisel Co. Ltd. 
Littelfuse. 
SUN Electronics 
Walter Electronic. 
50T 
218 
06.3
 
5T 
TSD 
T6.3A L 250V 
IEC60127 
VDE 
VDE 
VDE 
VDE 
F907 Mains 
fuse 
alt. 
alt. 
alt. 
Orisel Co. Ltd. 
Littelfuse. 
SUN Electronics 
Walter Electronic. 
50T 
218 
004
 
5T 
TSD 
T4A L 250V 
IEC60127 
VDE 
VDE 
VDE 
VDE 
C124 X-capacitor 
alt. 
alt. 
alt. 
Pilkor Electronics. 
ISKRA Elect. 
Okaya Electric Inc. 
Yuchang 
Electronics. 
PCX2 335M 
KNB1530 
RE104 
WBU1942 
0.10uF 275V 
X2 
IEC60384-
14, 2
nd
 ed. 
FIMKO 
FIMKO 
VDE 
FIMKO 
C853 
(switch across) 
 
C904 
(relay across)
 
X-capacitor 
alt. 
alt.  
alt. 
alt. 
Du San Industrial. 
Netron Tech. 
Sam Wha Capacitor. 
Murata Mfg. 
Jyh Chung Elect. 
NU 
AA 
SC 
KH 
JY 
0.0047uF/250V, 
X1. 
IEC
60384-
14, 
2
nd
 ed. 
FIMKO 
FIMKO 
FIMKO 
FIMKO 
FIMKO 
 PCB 
base 
material 
Various 
Various 
Min 94V-1 
UL 796 
UL 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
**) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively 
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 6.Edition : 1998 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 35 of 38 - 
 
 
   
 Order 
No. 
34019
 
 
 
 
 
FAULT CONDITION TESTS   
Ambient temperature   
24 - 26 °C 
Rated voltage   
230V~ 50Hz 
Remarks  
Comp. 
No 
Fault Test 
Short 
current 
Test time
Fuse No
Current 
through 
fuse 
Mains power/temperatures/results 
D104 
S-c 
253 
A - C 
30 min 
F907 
1,50 A 
Normal operated. 
Input current stabilised at 1,50A. 
R106
 
opened.  No hazard. 
C122 
S-c 
253 
30 min 
F907 
1,59 A 
FL display off immediately. 
Input current stabilised at 1,44A. 
R101 opened.  No hazard. 
C119 
S-c 
253 
30 min 
F907 
1,69 A 
FL display off immediately. 
Input current stabilised at 1,43A. 
Q104 damaged and R101 opened. 
No hazard. 
C117 
S-c 
253 
30 min 
F907 
1,46 A 
Normal operated. 
Input current stabilised at 1,45A. 
No component damaged. 
No hazard. 
D991 
S-c 
207 
AC - + 
10 min 
F907 
F903 
F904 
- Normal 
operated. 
Input current stabilised at 1,32A. 
F904 opened.  No hazard. 
D991 
S-c 
253 
AC - + 
10 min 
F907 
F903 
F904 
- Normal 
operated. 
Input current stabilised at 1,41A. 
F904 opened.  No hazard. 
D992 
S-c 
253 
AC - + 
10 min 
F907 
F905 
F906 
- Normal 
operated. 
Input current stabilised at 1,42A. 
F906 opened. 
No hazard. 
C928 
S-c 
253 
30 min 
F907 
1,63 A 
FL display off immediately. 
Input current stabilised at 1,43A. 
R106, R107 opened.    No hazard. 
C922 
S-c 
253 
30 min 
F907 
1,46 A 
FL display off immediately. 
Input current stabilised at 1,44A. 
No component damaged. 
No hazard. 
D904 
S-c 
253 
A - C 
30 min 
F907 
1,48 A 
Normal operated. 
Input current stabilised at 1,46A. 
R104 opened.  No hazard. 
C929 
S-c 
253 
30 min 
F907 
0,70 A 
Output signal off immediately. 
Input current stabilised at 0,45A. 
R104, R105 opened.    No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
Page of 51
Display