Harman Kardon AVR 135 EMC - CB Certificate ▷ View online
-
IEC 60065, 6th edition : 1998
-
- Page 32 of 38 -
Order
No.
34019
A
ANNEX A, ADDITIONAL
REQUIREMENTS FOR
APPARATUS WITH PROTECTION
AGAINST SPLASHING WATER
REQUIREMENTS FOR
APPARATUS WITH PROTECTION
AGAINST SPLASHING WATER
Not intended for outdoor use.
N
A.5.1
j) Marked with IPX4 (IEC 60 529),
5.4.1 a) does not apply
5.4.1 a) does not apply
N
A.10.2.1
Enclosure provides protection
against splashing water
against splashing water
N
A.10.2.2
Humidity treatment carried out for
7 days
7 days
N
B
ANNEX B, APPARATUS TO BE
CONNECTED TO THE
TELECOMMUNICATION
NETWORKS
CONNECTED TO THE
TELECOMMUNICATION
NETWORKS
Not intended for telecommunication networks
N
B.5.4.1
e) Where the separation of TNV
circuits from other circuits relies on
protective earthing the instructions
make it clear that protective earthing
is essential
circuits from other circuits relies on
protective earthing the instructions
make it clear that protective earthing
is essential
N
B.8.1
TNV circuits separated from the
mains circuit and from hazardous
live parts by either:
mains circuit and from hazardous
live parts by either:
N
a) double or reinforced insulation
N
b) basic insulation with earthed
protective screening
protective screening
N
B.8.2
TNV circuits separated from circuits
other than those in B.8.1 and from
accessible conductive parts by basic
insulation meeting the requirements
for clearances and creepage
distances for the voltages concerned
other than those in B.8.1 and from
accessible conductive parts by basic
insulation meeting the requirements
for clearances and creepage
distances for the voltages concerned
N
B.9.1.1
TNV circuit terminals contacts which
cannot be touched by probe B.1,
exempt from the requirements
inaccessible terminal contacts in
9.1.1
cannot be touched by probe B.1,
exempt from the requirements
inaccessible terminal contacts in
9.1.1
N
B.10.1
Insulation between TNV terminals
and antenna terminals (including
interconnection terminals which may
be connected to equipment with
antenna terminals) withstands the
50 discharges of 10.1
and antenna terminals (including
interconnection terminals which may
be connected to equipment with
antenna terminals) withstands the
50 discharges of 10.1
N
B.14.12
Surge suppressors between TNV
circuits and other parts of the
equipment have breakdown voltage
at least 1,8 times the mains voltage
circuits and other parts of the
equipment have breakdown voltage
at least 1,8 times the mains voltage
N
-
IEC 60065, 6th edition : 1998
-
- Page 33 of 38 -
Order
No.
34019
LIST OF CRITICAL COMPONENTS
P
Part No
Component/
Object
Object
Manufacturer
Type / Model
Ratings /
Technical Data
Technical Data
Complies
with the
following
standard
with the
following
standard
Marks of
conformity
granted **
conformity
granted **
For
CENELEC
Countries
CENELEC
Countries
Mains plug
with cord
with cord
Kenic Electric Mfg.
KE-21
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1
VDE
alt.
Kenic Electric Mfg.
KE-32
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1
VDE
alt. Phino
Electrical
Wire & Cable
PHP-205
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1
VDE
alt.
Kuk Je Tong shin
KKJ-1004A
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1
VDE
alt.
Volex (Asia) Pte.
Ltd.
Ltd.
M4206
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1
VDE
alt.
HWAJIN KDK Co.
KKP-419C
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1
VDE
For U.K.
Mains plug
with cord
with cord
PHINO Electronics
Co., Ltd
Co., Ltd
PHP-307F
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
alt.
Volex (Asia) Pte Ltd.
MP5004A
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
alt.
Volex (Asia) Pte Ltd.
MP5005
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
alt.
Winbo Industries
MS 323N
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
alt. Luen
Tai
(IP’S)
Elect.
Kenic Electric Mfg.
9518
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
alt.
Well Shin Enterprise
Co. Ltd.
Co. Ltd.
WS-012A
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
OL91 Mains
Socket-outlet
Dae Ryung
Electronics.
Electronics.
A3-04-D007 2.5A/250V IEC60884-1
NEMKO
Main transf.
Bobbin Mtl.
Bobbin Mtl.
Thermal fuse
Seoul Electronics &
Telecom Co., Ltd.
Wintech Polymer Ltd.
Telecom Co., Ltd.
Wintech Polymer Ltd.
Anzen Dengu Co.Ltd
KLT5V037ZE /
CLT5V037ZE
CLT5V037ZE
CN9030
L8
230V, Class B
V-0, 155°C
V-0, 155°C
5A/250V, 169℃
IEC60065
clause 14.3
UL94
clause 14.3
UL94
IEC60691
1.)
UL,
UL,
E2131445
VDE
**) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 6.Edition : 1998
-
IEC 60065, 6th edition : 1998
-
- Page 34 of 38 -
Order
No.
34019
LIST OF CRITICAL COMPONENTS (continued)
P
Part No
Component/
Object
Object
Manufacturer
Type / Model
Ratings /
Technical Data
Technical Data
Complies
with the
following
standard
with the
following
standard
Marks of
conformity
granted **
conformity
granted **
Sub
transformer
Bobbin Mtl.
alt.
alt.
Thermal fuse
transformer
Bobbin Mtl.
alt.
alt.
Thermal fuse
Seoul Electronics &
Telecom Co., Ltd.
EI
Telecom Co., Ltd.
EI
DUPONT.
Wintech Polymer Ltd.
Samyang Co.
Uchihashi Estec Co.
Samyang Co.
Uchihashi Estec Co.
KLT5J033ZE /
CLT5J033ZE
FR530
CN9030
2550GN30
423
CLT5J033ZE
FR530
CN9030
2550GN30
423
230V, Class E
V-0, 155°C
V-0, 155°C
V-0, 140°C
V-0, 155°C
V-0, 155°C
V-0, 140°C
0.5A/250V 130
°C
IEC60065
clause 14.3
UL94
UL94
UL94
IEC60691
clause 14.3
UL94
UL94
UL94
IEC60691
1.)
UL,
UL,
E69578
UL,
E2131445
UL,
E121254
VDE
SW1
Mains switch
POSTEC Electric. SDL1P-B
5A/80A
250V IEC60065
IEC61058-
1
1
VDE
RY94
Mains relay
Tyco Electronics
SDT-S-112DMR
8A/120A 250V
IEC60065
IEC61058-
1
IEC61058-
1
SEMKO
F901, F902
Outlet fuse
alt.
alt.
alt.
alt.
Littelfuse B.V.
Bel Fuse.
Save Fusetech.
Bel Fuse.
Save Fusetech.
0663
MRT
SR-5
MRT
SR-5
T2.5A 250V
IEC60127
VDE
VDE
VDE
VDE
VDE
F903, F904
F905, F906
F905, F906
Sec. fuse
alt.
alt.
alt.
alt.
alt.
alt.
Orisel Co. Ltd.
Littelfuse.
SUN Electronics
Walter Electronic.
Littelfuse.
SUN Electronics
Walter Electronic.
50T
218
218
06.3
5T
TSD
TSD
T6.3A L 250V
IEC60127
VDE
VDE
VDE
VDE
VDE
VDE
VDE
F907 Mains
fuse
alt.
alt.
alt.
alt.
alt.
Orisel Co. Ltd.
Littelfuse.
SUN Electronics
Walter Electronic.
Littelfuse.
SUN Electronics
Walter Electronic.
50T
218
218
004
5T
TSD
TSD
T4A L 250V
IEC60127
VDE
VDE
VDE
VDE
VDE
VDE
VDE
C124 X-capacitor
alt.
alt.
alt.
alt.
alt.
Pilkor Electronics.
ISKRA Elect.
Okaya Electric Inc.
Yuchang
Electronics.
ISKRA Elect.
Okaya Electric Inc.
Yuchang
Electronics.
PCX2 335M
KNB1530
RE104
WBU1942
KNB1530
RE104
WBU1942
0.10uF 275V
X2
X2
IEC60384-
14, 2
14, 2
nd
ed.
FIMKO
FIMKO
VDE
FIMKO
FIMKO
VDE
FIMKO
C853
(switch across)
C904
(relay across)
X-capacitor
alt.
alt.
alt.
alt.
alt.
alt.
alt.
alt.
Du San Industrial.
Netron Tech.
Sam Wha Capacitor.
Murata Mfg.
Jyh Chung Elect.
Netron Tech.
Sam Wha Capacitor.
Murata Mfg.
Jyh Chung Elect.
NU
AA
SC
KH
JY
AA
SC
KH
JY
0.0047uF/250V,
X1.
X1.
IEC
60384-
14,
2
nd
ed.
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
PCB
base
material
Various
Various
Min 94V-1
UL 796
UL
**) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 6.Edition : 1998
-
IEC 60065, 6th edition : 1998
-
- Page 35 of 38 -
Order
No.
34019
FAULT CONDITION TESTS
P
Ambient temperature
24 - 26 °C
Rated voltage
230V~ 50Hz
Remarks
-
Comp.
No
No
Fault Test
V
Short
current
current
Test time
Fuse No
Current
through
fuse
through
fuse
Mains power/temperatures/results
D104
S-c
253
A - C
30 min
F907
1,50 A
Normal operated.
Input current stabilised at 1,50A.
R106
Input current stabilised at 1,50A.
R106
opened. No hazard.
C122
S-c
253
-
30 min
F907
1,59 A
FL display off immediately.
Input current stabilised at 1,44A.
R101 opened. No hazard.
Input current stabilised at 1,44A.
R101 opened. No hazard.
C119
S-c
253
-
30 min
F907
1,69 A
FL display off immediately.
Input current stabilised at 1,43A.
Q104 damaged and R101 opened.
No hazard.
Input current stabilised at 1,43A.
Q104 damaged and R101 opened.
No hazard.
C117
S-c
253
-
30 min
F907
1,46 A
Normal operated.
Input current stabilised at 1,45A.
No component damaged.
No hazard.
Input current stabilised at 1,45A.
No component damaged.
No hazard.
D991
S-c
207
AC - +
10 min
F907
F903
F904
F903
F904
- Normal
operated.
Input current stabilised at 1,32A.
F904 opened. No hazard.
F904 opened. No hazard.
D991
S-c
253
AC - +
10 min
F907
F903
F904
F903
F904
- Normal
operated.
Input current stabilised at 1,41A.
F904 opened. No hazard.
F904 opened. No hazard.
D992
S-c
253
AC - +
10 min
F907
F905
F906
F905
F906
- Normal
operated.
Input current stabilised at 1,42A.
F906 opened.
No hazard.
F906 opened.
No hazard.
C928
S-c
253
-
30 min
F907
1,63 A
FL display off immediately.
Input current stabilised at 1,43A.
R106, R107 opened. No hazard.
Input current stabilised at 1,43A.
R106, R107 opened. No hazard.
C922
S-c
253
-
30 min
F907
1,46 A
FL display off immediately.
Input current stabilised at 1,44A.
No component damaged.
No hazard.
Input current stabilised at 1,44A.
No component damaged.
No hazard.
D904
S-c
253
A - C
30 min
F907
1,48 A
Normal operated.
Input current stabilised at 1,46A.
R104 opened. No hazard.
Input current stabilised at 1,46A.
R104 opened. No hazard.
C929
S-c
253
-
30 min
F907
0,70 A
Output signal off immediately.
Input current stabilised at 0,45A.
R104, R105 opened. No hazard.
Input current stabilised at 0,45A.
R104, R105 opened. No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection