Harman Kardon AVR 135 EMC - CB Certificate ▷ View online
-
IEC 60065, 6th edition : 1998
-
- Page 36 of 38 -
Order
No.
34019
FAULT CONDITION TESTS (continued)
P
Comp.
No
No
Fault Test
V
Short
current
current
Test time
Fuse No
Current
through
fuse
through
fuse
Mains power/temperatures/results
C923
S-c
253
-
30 min
F907
1,03 A
Output signal off immediately.
Input current stabilised at 0,55A.
No component damaged.
No hazard.
Input current stabilised at 0,55A.
No component damaged.
No hazard.
D915
S-c
253
A - C
30 min
F907
1,57 A
Output signal dropped to 4V.
Input current stabilised at 1,10A.
R104 opened and D916 damaged.
No hazard.
Input current stabilised at 1,10A.
R104 opened and D916 damaged.
No hazard.
C931
S-c
253
-
30 min
F907
0,90 A
Output signal off immediately.
Input current stabilised at 0,47A.
R104, R105 opened and
D915 damaged. No hazard.
Input current stabilised at 0,47A.
R104, R105 opened and
D915 damaged. No hazard.
C909 S-c
207 -
10
min
F907
F905
F906
F905
F906
-
Surround, Center channels signal
output off immediately.
Input current stabilised at 0,81 A.
F905, F906 opened.
No hazard.
output off immediately.
Input current stabilised at 0,81 A.
F905, F906 opened.
No hazard.
C909 S-c
253 -
10
min
F907
F905
F906
F905
F906
-
Surround, Center channels signal
output off immediately.
Input current stabilised at 0,90 A.
F905, F906 opened.
No hazard.
output off immediately.
Input current stabilised at 0,90 A.
F905, F906 opened.
No hazard.
C916 S-c
253 -
10
min
F907
F903
F904
F903
F904
-
Front, S/B channels signal output
off immediately.
Input current stabilised at 0,86A.
F903, F904 opened.
No hazard.
off immediately.
Input current stabilised at 0,86A.
F903, F904 opened.
No hazard.
Q803
S-c
207
C - E
10 min
F907
F905
F906
F905
F906
-
Unit shut down immediately.
Input current stabilised at 0,01A.
F905, F906 opened.
No hazard.
Input current stabilised at 0,01A.
F905, F906 opened.
No hazard.
Q803
S-c
253
C - E
10 min
F907
F905
F906
F905
F906
-
Unit shut down immediately.
Input current stabilised at 0,01A.
F905, F906 opened.
Q804 shorted.
No hazard.
Input current stabilised at 0,01A.
F905, F906 opened.
Q804 shorted.
No hazard.
Q803
S-c
253
B - C
10 min
F907
F905
F906
F905
F906
-
Unit shut down immediately.
Input current stabilised at 0,01A.
No component damaged.
No hazard.
Input current stabilised at 0,01A.
No component damaged.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
-
IEC 60065, 6th edition : 1998
-
- Page 37 of 38 -
Order
No.
34019
FAULT CONDITION TESTS (continued)
P
Comp.
No
No
Fault Test
V
Short
current
current
Test time
Fuse No
Current
through
fuse
through
fuse
Mains power/temperatures/results
C807 S-c
253 -
20
min
F907
F905
F906
F905
F906
1,79 A
Surround L channel signal output
distorted immediately.
Input current stabilised at 1,33A.
R611, R821 opened.
No hazard.
distorted immediately.
Input current stabilised at 1,33A.
R611, R821 opened.
No hazard.
Q804
S-c
253
C - E
10 min
F907
F905
F906
F905
F906
-
Unit shut down immediately.
Input current stabilised at 0,01A.
F905, F906 opened.
Q803, Q804 shorted and
R810 opened. No hazard.
Input current stabilised at 0,01A.
F905, F906 opened.
Q803, Q804 shorted and
R810 opened. No hazard.
Q804
S-c
253
B - C
10 min
F907
F905
F906
F905
F906
-
Unit shut down immediately.
Input current stabilised at 0,01A.
Q803 shorted. No hazard.
Input current stabilised at 0,01A.
Q803 shorted. No hazard.
C813 S-c
253 -
20
min
F907
F905
F906
F905
F906
1,29 A
Surround L channel signal output
off immediately.
Input current stabilised at 1,26A.
No component damaged.
No hazard.
off immediately.
Input current stabilised at 1,26A.
No component damaged.
No hazard.
D962
S-c
253
A - C
12 min
-
1,47 A
Sub transformer primary winding
heated-up to 106K and thermal fuse
opened after 12 min.
Dielectric strength test O.K.
No hazard.
heated-up to 106K and thermal fuse
opened after 12 min.
Dielectric strength test O.K.
No hazard.
C906
S-c
253
-
11 min
-
0,04 A
Mains relay off immediately.
Sub transformer primary winding
heated-up to 110K and thermal fuse
opened after 11 min.
Dielectric strength test O.K.
No hazard.
Sub transformer primary winding
heated-up to 110K and thermal fuse
opened after 11 min.
Dielectric strength test O.K.
No hazard.
C911
S-c
253
-
2 hr
-
0,02 A
Mains relay off immediately.
Sub transformer primary winding
heated-up to 87K and stabilised.
Dielectric strength test O.K.
No hazard.
Sub transformer primary winding
heated-up to 87K and stabilised.
Dielectric strength test O.K.
No hazard.
Speaker
Terminal
Terminal
S-c 253
Surroun
d
(
d
(
L - ch.)
10 min
F907
-
Unit shut down immediately.
Input current stabilised at 0,01A.
No component damaged.
No hazard.
Input current stabilised at 0,01A.
No component damaged.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
-
IEC 60065, 6th edition : 1998
-
- Page 38 of 38 -
Order
No.
34019
FAULT CONDITION TESTS (continued)
P
Comp.
No
No
Fault Test
V
Short
current
current
Test time
Fuse No
Current
through
fuse
through
fuse
Mains power/temperatures/results
Top cover
opening
opening
Blocked
253
-
10 min
F907
1,45 A
Unit shut down after 6 min.
Input current stabilised at 0,01A.
No component damaged.
No hazard.
Input current stabilised at 0,01A.
No component damaged.
No hazard.
Pmax
operating
Maximum
non-
clipped
output
signal
non-
clipped
output
signal
253
-
24 min
F907
3,05 A
The components are heated up to:
- Main transf. pr. Winding : 147K
- Main transformer core
- Main transf. pr. Winding : 147K
- Main transformer core
: 89K
- D992 body
: 93K
- PWB near D992
: 94K
- Q803 body
: 52K
- PWB near Q804
: 44K
and main transformer’s thermal fuse
opened after 24 min.
Dielectric strength test OK.
No hazard.
opened after 24 min.
Dielectric strength test OK.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
- APPENDIX CENELEC EN60065:1998 TO IEC60065:1998 -
- Page 1 of 3 -
Order
No.
34019
APPENDIX
CENELEC EN 60065:1998
CENELEC COMMON MODIFICATIONS, SPECIAL NATIONAL CONDITIONS, NATIONAL
DEVIATIONS AND OTHER INFORMATION
DEVIATIONS AND OTHER INFORMATION
P
C = CENELEC common modification, S = Special National condition, D = National deviation, F = Other information
DE
= Germany, DK = Denmark, GB = United kingdom, FI = Finland, IE = Ireland, IT = Italy, NO = Norway, SE = Sweden.
P = Pass, F = Fail, N = Not applicable.
P = Pass, F = Fail, N = Not applicable.
1.1.1 C
Replace text in Note 1 by : This
standard can be used as a guide for
the testing of battery operated
apparatus.
standard can be used as a guide for
the testing of battery operated
apparatus.
N
2.6.1 S
(DK) Class I apparatus provided
with a plug not establishing earthing
continuity when inserted in Danish
socket-outlets, see 15.1.1.
with a plug not establishing earthing
continuity when inserted in Danish
socket-outlets, see 15.1.1.
Class II apparatus
N
3.1 C
Delete the note. Add the following
indent : exposure to excessive
sound pressures from headphones
or earphones.
indent : exposure to excessive
sound pressures from headphones
or earphones.
5 D
(DE) Marking in case of intrinsically
ionizing radiation, cathode-ray tubes
ionizing radiation, cathode-ray tubes
N
5 D
(IT) Marking and instruction
requirements
- power consumption (W) for TV
receivers
requirements
- power consumption (W) for TV
receivers
N
6.1 D
(DE) Limits for ionizing radiation, TV
receivers (max. 1
receivers (max. 1
µSv/h)
N
15.1.1 C
Delete notes 1 and 2.
Add to note 4: Attention is drawn to
the fact that a standard is under
preparation (presently prEN 50074)
for socket-outlets which allow
connection of Class II appliances
only.
Add to note 4: Attention is drawn to
the fact that a standard is under
preparation (presently prEN 50074)
for socket-outlets which allow
connection of Class II appliances
only.
15.1.1 S
(DK) Mains plug according to Heavy
Current Regulations, Section 107-2-
D1
(DK) Mains socket outlets Cl.I
(DK) Mains socket outlets Cl.II
Current Regulations, Section 107-2-
D1
(DK) Mains socket outlets Cl.I
(DK) Mains socket outlets Cl.II
P
15.1.1 S
(IE) Mains plug, flexible cord,
according to statutory Instrument
525: 1997
according to statutory Instrument
525: 1997
P
15.1.1 S
(NO) Mains socket outlets CI.II
P
15.1.1 S
(GB) Mains plug, flexible cord,
according to statutory Instrument
1768: 1994
according to statutory Instrument
1768: 1994
P