IEC 60065, 6th edition : 1998
 - 
- Page 36 of 38 - 
 
 
   
 Order 
No. 
34019
 
 
 
 
 
FAULT CONDITION TESTS (continued) 
Comp. 
No 
Fault Test 
Short 
current 
Test time
Fuse No
Current 
through 
fuse 
Mains power/temperatures/results 
C923 
S-c 
253 
30 min 
F907 
1,03 A 
Output signal off immediately. 
Input current stabilised at 0,55A. 
No component damaged. 
No hazard. 
D915 
S-c 
253 
A - C 
30 min 
F907 
1,57 A 
Output signal dropped to 4V. 
Input current stabilised at 1,10A. 
R104 opened and D916 damaged. 
No hazard. 
C931 
S-c 
253 
30 min 
F907 
0,90 A 
Output signal off immediately. 
Input current stabilised at 0,47A. 
R104, R105 opened and 
D915 damaged.  No hazard. 
C909 S-c 
207  - 
10 
min 
F907 
F905 
F906 
Surround, Center channels signal 
output off immediately. 
Input current stabilised at 0,81 A. 
F905, F906 opened. 
No hazard. 
C909 S-c 
253  - 
10 
min 
F907 
F905 
F906 
Surround, Center channels signal 
output off immediately. 
Input current stabilised at 0,90 A. 
F905, F906 opened. 
No hazard. 
C916 S-c 
253  - 
10 
min 
F907 
F903 
F904 
Front, S/B channels signal output 
off immediately. 
Input current stabilised at 0,86A. 
F903, F904 opened. 
No hazard. 
Q803 
S-c 
207 
C - E 
10 min 
F907 
F905 
F906 
Unit shut down immediately. 
Input current stabilised at 0,01A. 
F905, F906 opened. 
No hazard. 
Q803 
S-c 
253 
C - E 
10 min 
F907 
F905 
F906 
Unit shut down immediately. 
Input current stabilised at 0,01A. 
F905, F906 opened. 
Q804 shorted. 
No hazard. 
Q803 
S-c 
253 
B - C 
10 min 
F907 
F905 
F906 
Unit shut down immediately. 
Input current stabilised at 0,01A. 
No component damaged. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 37 of 38 - 
 
 
   
 Order 
No. 
34019
 
 
 
 
 
FAULT CONDITION TESTS (continued) 
Comp. 
No 
Fault Test 
Short 
current 
Test time
Fuse No
Current 
through 
fuse 
Mains power/temperatures/results 
C807 S-c 
253  - 
20 
min 
F907 
F905 
F906 
1,79 A 
Surround L channel signal output 
distorted immediately. 
Input current stabilised at 1,33A. 
R611, R821 opened. 
No hazard. 
Q804 
S-c 
253 
C - E 
10 min 
F907 
F905 
F906 
Unit shut down immediately. 
Input current stabilised at 0,01A. 
F905, F906 opened. 
Q803, Q804 shorted and 
R810 opened. No hazard. 
Q804 
S-c 
253 
B - C 
10 min 
F907 
F905 
F906 
Unit shut down immediately. 
Input current stabilised at 0,01A. 
Q803 shorted.  No hazard. 
C813 S-c 
253  - 
20 
min 
F907 
F905 
F906 
1,29 A 
Surround L channel signal output 
off immediately. 
Input current stabilised at 1,26A. 
No component damaged. 
No hazard. 
D962 
S-c 
253 
A - C 
12 min 
1,47 A 
Sub transformer primary winding 
heated-up to 106K and thermal fuse
opened after 12 min. 
Dielectric strength test O.K. 
No hazard. 
C906 
S-c 
253 
11 min 
0,04 A 
Mains relay off immediately. 
Sub transformer primary winding 
heated-up to 110K and thermal fuse
opened after 11 min. 
Dielectric strength test O.K. 
No hazard. 
C911 
S-c 
253 
2 hr 
0,02 A 
Mains relay off immediately. 
Sub transformer primary winding 
heated-up to 87K and stabilised. 
Dielectric strength test O.K. 
No hazard. 
Speaker 
Terminal 
S-c 253 
Surroun

(
L - ch.)
 
10 min 
F907 
Unit shut down immediately. 
Input current stabilised at 0,01A. 
No component damaged. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 38 of 38 - 
 
 
   
 Order 
No. 
34019
 
 
 
 
 
FAULT CONDITION TESTS (continued) 
Comp. 
No 
Fault Test 
Short 
current 
Test time
Fuse No
Current 
through 
fuse 
Mains power/temperatures/results 
Top cover 
opening 
Blocked 
253 
10 min 
F907 
1,45 A 
Unit shut down after 6 min. 
Input current stabilised at 0,01A. 
No component damaged. 
No hazard. 
Pmax 
operating
 
Maximum 
non-
clipped 
output 
signal 
253 
24 min 
F907 
3,05 A 
The components are heated up to: 
- Main transf. pr. Winding  : 147K 
- Main transformer core 
: 89K 
- D992 body 
: 93K 
- PWB near D992 
: 94K 
- Q803 body 
: 52K 
- PWB near Q804 
: 44K 
and main transformer’s thermal fuse
opened after 24 min. 
Dielectric strength test OK. 
No hazard. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
 
 
- APPENDIX CENELEC EN60065:1998 TO IEC60065:1998    -
 
- Page 1 of 3 - 
 
 
   
 Order 
No. 
34019
 
 
 
APPENDIX   
CENELEC EN 60065:1998 
CENELEC COMMON MODIFICATIONS, SPECIAL NATIONAL CONDITIONS, NATIONAL 
DEVIATIONS AND OTHER INFORMATION     
C = CENELEC common modification, S = Special National condition, D = National deviation, F = Other information
 DE 
= Germany, DK = Denmark, GB = United kingdom, FI = Finland, IE = Ireland, IT = Italy, NO = Norway, SE = Sweden. 
P = Pass, F = Fail, = Not applicable.   
1.1.1 C 
Replace text in Note 1 by : This 
standard can be used as a guide for 
the testing of battery operated 
apparatus.  
 
2.6.1 S 
(DK)    Class I apparatus provided 
with a plug not establishing earthing 
continuity when inserted in Danish 
socket-outlets, see 15.1.1. 
 
Class II apparatus 
3.1 C 
Delete the note. Add the following 
indent : exposure to excessive 
sound pressures from headphones 
or earphones. 
 
 
 
D 
(DE) Marking in case of intrinsically 
ionizing radiation, cathode-ray tubes
 
D 
(IT) Marking and instruction 
requirements  
- power consumption (W) for TV 
receivers  
 
6.1 D 
(DE) Limits for ionizing radiation, TV 
receivers (max. 1
µSv/h) 
 
15.1.1 C 
Delete notes 1 and 2. 
Add to note 4: Attention is drawn to 
the fact that a standard is under 
preparation (presently prEN 50074) 
for socket-outlets which allow 
connection of Class II appliances 
only.  
 
 
15.1.1 S 
(DK) Mains plug according to Heavy 
Current Regulations, Section 107-2-
D1 
(DK) Mains socket outlets Cl.I 
(DK) Mains socket outlets Cl.II 
 P 
15.1.1 S 
(IE) Mains plug, flexible cord, 
according to statutory Instrument 
525: 1997 
 
15.1.1 S 
(NO) Mains socket outlets CI.II 
 
15.1.1 S 
(GB) Mains plug, flexible cord, 
according to statutory Instrument 
1768: 1994 
 
Page of 51
Display

Click on the first or last page to see other AVR 135 service manuals if exist.