5-33
3-8.
LCD SYSTEM ADJUSTMENT
(GV-D900/D900E)
Note1:
The back light (fluorescent tube) is driven by a high voltage AC
power supply. Therefore, do not touch the back light holder to avoid
electrical shock.
Note2:
When replacing the LCD unit, be careful to prevent damages caused
by static electricity.
Note3:
Set the LCD BRIGHT (IO-64 board S103,104) to the center.
Note4:
Before perform the LCD system adjustment, check that the
specified value of “Base Band Block Adjustments” of “VIDEO
SYSTEM ADJUSTMENTS” is satisfied.
 [Adjusting connector]
Most of the measuring points for adjusting the LCD display are
concentrated in the following connector.
CN9925 of the CB-61 board
Connect the Measuring Instruments via the CPC-10 jig (J-6082-
424-A).
The following table shows the Pin No. and signal name of the
connector.
[Video input signal for adjustments]
If stated as “10-step stair-step” in the signal column, input the 10-
step stair-step signal in the video input terminal as the video input
signal for the adjusting. Check that the input signal level is 1.00
Vp-p before adjusting.
Fig. 5-3-25.      10 steps star-steps
Pin No.
1
2
3
4
5
Signal name
VR
VG
VB
V COM
GND
Pin No.
6
7
8
9
Signal name
C SYNC
HDB
SRT
FRP
1. LCD Initial Data Input
Mode
VTR stop
Signal
Arbitrary
Adjustment Page
D
Adjustment Address
60 to 68, 6A to 6F
Adjusting method:
1)
Select page: 0, address:01, and set data: 01.
2)
Select page: D, and input the data in the following table.
Note:
 To write in the non-volatile memory (EEPROM), press the
PAUSE button of the adjustment remote commander each time
to set the data.
3)
Select page: 0, address:01, and set data: 00.
Address
60
61
62
63
64
65
66
67
68
6A
6B
6C
6D
6E
6F
Data
NTSC
75
71
71
74
CA
8E
7F
7E
5E
50
50
7E
8E
32
44
PAL
96
76
76
7F
CA
86
7F
7E
6A
50
50
7A
6E
32
22
Remark
Hue adjustment
White balance adjustment
White balance adjustment
Contrast adjustment
PANEL –19V adjustment
V-COM adjustment
Fixed value
Fixed value
Horizontal position adjustment
Fixed value
Fixed value
Bright adjustment
Color adjustment
Fixed value
Fixed value
Approx.
0.714V
Approx.
0.286V
H sync
0 IRE
100 IRE
1.00V   
5-34
2. PANEL –19V Adjustment (CB-61 board)
Mode
VTR stop
Signal
No signal
Measurement Point
Pin 
!ª of CN9928 (CPC VGL –18V)
Measuring Instrument
Digital voltmeter
Adjustment Page
D
Adjustment Address
64
Specified Value
A = –19.0 ± 0.5Vdc
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 64, change the data and set the DC
voltage (A) to the specified value.
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: 0, address: 01, and set data: 00.
3. Horizontal Position Adjustment (CB-61 board)
Adjust the position of the image.
If its position is not correct. it will slip to the right or left.
Mode
VTR stop
Signal
Color bar
Measurement Point
CH1: Pin 
9 of CN9925 (FRP)
CH2: Pin 
6 of CN9925 (CSYNC)
Measuring Instrument
Oscilloscope
Trigger source: CH1
Adjustment Page
D
Adjustment Address
68
Specified Value
T = 4.81 ± 0.10 
µ
sec
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 68, change the data and set the delay
time (T) to the specified value.
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: 0, address: 01, and set data: 00.
Fig. 5-3-26.
CH1
CH2
CH1
CH2
Enlargement
T
2H
5-35
4. Bright Adjustment (CB-61 board)
Set the level of the VIDEO signal for driving the LCD to the specified
value. If deviated, the screen image will be blackish or saturated
(whitish).
Mode
VTR stop
Signal
10-step stair-step signal or color bar
signal whose chroma and burst signals
are turned off
Measurement Point
Pin 
2 of CN9925 (VG)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
6C
Specified Value
A = 4.00 ± 0.05V (NTSC)
A = 4.15 ± 0.05V (PAL)
Note:
Perform “4. Bright Adjustment” and “5. Contrast Adjustment”
alternately until each specified value is satisfied.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 6C, change the data and set the voltage
(A) between the reversed waveform pedestal and non-reversed
waveform pedestal to the specified value.
 (The data of address: 6C should be “41” to “BF”.)
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: 0, address: 01, and set data: 00.
5)
Perform “Contrast Adjustment”.
Fig. 5-3-27.
5. Contrast Adjustment (CB-61 board)
Set the level of the VIDEO signal for driving the LCD to the specified
value. If deviated, the screen image will be blackish or saturated
(whitish).
Mode
VTR stop
Signal
10-step stair-step signal or color bar
signal whose chroma and burst signals
are turned off
Measurement Point
Pin 
2 of CN9925 (VG)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
63
Specified Value
A = 2.90 ± 0.05V (NTSC)
A = 3.22 ± 0.05V (PAL)
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 63, change the data and set the voltage
(A) between the 0 IRE (pedestal) and 90 IRE to the specified
value.
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: 0, address: 01, and set data: 00.
5)
Check that the specified value of “Bright Adjustment” is
satisfied, if not perform “Bright Adjustment”.
Fig. 5-3-28.
Pedestal
Pedestal
A
2H
90 IRE
0 IRE
A
2H
5-36
6. Color Adjustment for NTSC model (CB-61 board)
Set the color saturation to the standard value. If deviated, the color
will be to dark or light.
Mode
VTR stop
Signal
Color bar
Measurement Point
Pin 
2 of CN9925 (VG)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
6D
Specified Value
A = 0.40 ± 0.05V
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 63, after noting down the data, add 10
(heximadecimal number) to the data.
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: D, address: 6D, change the data and set the voltage
(A) between the white(75%) and green to the specified value.
(The data of address: 6D should be “48” to “B7”.)
5)
Press the PAUSE button of the adjustment remote commander.
6)
Select page: D, address: 63, set the data noted down at step 2),
and press the PAUSE button.
7)
Select page: 0, address: 01, and set data: 00.
Fig. 5-3-29.
7. Hue Adjustment for NTSC model (CB-61 board)
Set the hue to the standard value. If deviated, the color will be to
unnatural.
Mode
VTR stop
Signal
Color bar
Measurement Point
Pin 
2 of CN9925 (VG)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
60
Specified Value
A = 0.15 ± 0.05V
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 63, after noting down the data, add 10
(heximadecimal number) to the data.
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: D, address: 60, change the data and set the voltage
(A) between the yellow and cyan to the specified value. (The
data of address: 60 should be “48” to “B7”.)
5)
Press the PAUSE button of the adjustment remote commander.
6)
Select page: D, address: 63, set the data noted down at step 2),
and press the PAUSE button.
7)
Select page: 0, address: 01, and set data: 00.
Fig. 5-3-30.
Green
White (75%)
A
2H
Cyan
Yellow
A
2H
Page of 127