5-21
10. S VIDEO Output Chroma Level Adjustment
    (CB-61 Board)
Set the chroma signal level of the S video output signal.
Mode
VTR stop
Signal
No signal
Measurement Point
Chroma signal terminal of S VIDEO
jack (75 
Ω 
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
94
Specified Value
A = 286 ± 6mV (NTSC)
A = 300 ± 6mV (PAL)
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 15, after memorizing the data, set the
bit value of bit2 to “0”. (Refer to “4-3, 3. Bit value
discrimination” of “5-4. Service Mode”).
3)
Select page: D, address: 94, change the data and set the burst
signal level (A) to the specified value.
4)
Press the PAUSE button of the adjustment remote commander.
5)
Select page: D, address: 15, and set the data memorized at step
2).
6)
Press the PAUSE button of the adjustment remote commander.
7)
Select page: 0, address: 01, and set data: 00.
Fig. 5-3-15
11. AFC TC Adjustment (CB-61 Board)
Set the picture frame in recording.
Mode
VTR stop
Signal
75% color bar (VIDEO jack input)
Measurement Point
Y signal terminal of S VIDEO jack
(75 
Ω 
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
A2
Specified Value
t
2
 – t
1
 = 0 ± 0.05 
µ
sec
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 2, address: 13, and set data: FE.
3)
Check the delay time (t
1
).
4)
Select page: 2, address: 13, and set data: FF.
5)
Select page: D, address: A2, change the data so that the delay
time (t
2
) is equal to the delay time (t
1
) of step 3).
6)
Press the PAUSE button of the adjustment remote commander.
7)
Select page: 2, address: 13, and set data: 00.
8)
Select page: 0, address: 01, and set data: 00.
For NTSC model
For PAL model
Fig. 5-3-16
A
H
H
t
1
 or t
2
H
t
1
 or t
2
5-22
12. AFC f
0
 Adjustment (CB-61 Board)
Set the free-run frequency of the AFC VCO.
Mode
VTR stop (GV-D900/D900E)
Recording (GV-D300/D300E)
Signal
75% color bar (VIDEO jack input)
Measurement Point
Pin 
@º of CN9928 (AFC ERR)
Measuring Instrument
Digital voltmeter
Adjustment Page
D
Adjustment Address
A1
Specified Value
A = 1.9 ± 0.1Vdc
Note:
Don’t insert any plug in the S VIDEO jack.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: A1, change the data and set the AFC
error voltage (A) to the specified value.
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: 0, address: 01, and set data: 00.
13. Decoder APC Adjustment (CB-61 Board)
Set the free-run frequency of the decoder VXO.
Mode
VTR stop (GV-D900/D900E)
Recording (GV-D300/D300E)
Signal
No signal (VIDEO jack input) (Note)
Measurement Point
Pin 
1 of CN9928 (DEC FSC)
Measuring Instrument
Frequency counter
Adjustment Page
D
Adjustment Address
9F
Specified Value
f = 3579545 ± 50Hz (NTSC)
f = 4433619 ± 50Hz (PAL)
Note:
 Insert a plug in the VIDEO jack.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 9F, change the data and set the DEC
FSC frequency (f) to the specified value.
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: 0, address: 01, and set data: 00.
14. Decoder ACC Adjustment (CB-61 Board)
Set the decoder ACC gain.
Mode
VTR stop (GV-D900/D900E)
Recording (GV-D300/D300E)
Signal
75% color bar (VIDEO jack input)
Measurement Point
Pin 
!¶ of CN9928 (DEC B-Y)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
9E
Specified Value
A = 325 ± 20mV
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 9E, change the data and set the DEC
B-Y signal level (A) to the specified value.
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: 0, address: 01, and set data: 00.
Fig. 5-3-17
H
A
5-23
15. Decoder HUE Adjustment (CB-61 Board)
Set the decoder hue.
Mode
VTR stop (GV-D900/D900E)
Recording (GV-D300/D300E)
Signal
75% color bar (VIDEO jack input)
Measurement Point
Pin 
!¶ of CN9928 (DEC B-Y)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
A0
Specified Value
A-B = 0 ± 10mV (NTSC)
A = Minimum amplitude (PAL)
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
NTSC model
Select page: D, address: A0, change the data so that the voltage
(A) between the yellow and cyan is equal to the voltage (B)
between the green and magenta.
PAL model
Select page: D, address: A0, change the data so that the
waveform dose not appear double.
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: 0, address: 01, and set data: 00.
For NTSC model
For PAL model
Fig. 5-3-18
H
B
A
A
H
16. Y AD Clamp Adjustment (CB-61 Board)
Set the IC9004 clamp level of the Y AD OUT.
Mode
VTR stop (GV-D900/D900E)
Recording (GV-D300/D300E)
Signal
75% color bar (VIDEO jack input)
Measurement Point
DDS display of LCD or TV monitor
(Note1), or Page: 2, address: 1C
display data of the adjustment remote
commander
Measuring Instrument
Adjustment Page
D
Adjustment Address
B6
Specified Value
0F to 11
Note1:
The two digits of the display data of the LCD and TV monitor is
the object data.
 HI XX XXXX
Object data
Note2:
How to connect the TV monitor.
1) Use the LASER LINK function.
2) Connect the TV monitor to S VIDEO jack.
In this case, select page: 2, address: 13, and set data: FE. After
completing adjustments, set data: 00 to the address.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 11, set data: 24, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 2, address: 96, and set data: 40.
4)
Select page: 2, address: 97, and set data: 18.
5)
Select page: D, address: B6, change the data and adjust the
DDS display data (or the display data of page: 2, address: 1C)
to the specified value. (The data of address: B6 should be “00”
to “99”.)
6)
Press the PAUSE button of the adjustment remote commander.
Processing after Completing Adjustments
1)
Select page: D, address: 11, set data: 00, and press the PAUSE
button of the adjustment remote commander.
2)
Select page: 0, address: 01, and set data: 00.
3)
Select page: 2, address: 96, and set data: 00.
4)
Select page: 2, address: 97, and set data: 00.
5-24
17. CR AD Clamp Adjustment (CB-61 Board)
Set the clamp level of the IC9004 CR AD OUT.
Mode
VTR stop (GV-D900/D900E)
Recording (GV-D300/D300E)
Signal
75% color bar (VIDEO jack input)
Measurement Point
DDS display of LCD or TV monitor
(Note), or Page: 2, address: 1D
display data of the adjustment remote
commander
Measuring Instrument
Adjustment Page
D
Adjustment Address
B4
Specified Value
FF or 00 or 01
Note:
Note: The two digits of the display data of the LCD and TV monitor
is the object data.
 HI XX XXXX
Object data
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 11, set data: 24, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 2, address: 96, and set data: 40.
4)
Select page: 2, address: 97, and set data: 18.
5)
Select page: D, address: B4, set data: 4C, and press the PAUSE
button of the adjustment remote commander.
6)
Select page: D, address: B5, set data: 4C, and press the PAUSE
button.
7)
Select page: D, address: B4, change the data and adjust the
DDS display data (or the display data of page: 2, address: 1D)
to the specified value. (The data of address: B4 should be “00”
to “99”.)
8)
Press the PAUSE button of the adjustment remote commander.
9)
Perform “CB AD Clamp Adjustment”.
Processing after Completing Adjustments
1)
Select page: D, address: 11, set data: 00, and press the PAUSE
button of the adjustment remote commander.
2)
Select page: 0, address: 01, and set data: 00.
3)
Select page: 2, address: 96, and set data: 00.
4)
Select page: 2, address: 97, and set data: 00.
18. CB AD Clamp Adjustment (CB-61 Board)
Set the clamp level of the IC9004 CB AD OUT.
Mode
VTR stop (GV-D900/D900E)
Recording (GV-D300/D300E)
Signal
75% color bar (VIDEO jack input)
Measurement Point
DDS display of LCD or TV monitor
(Note1), or Page: 2, address: 1E
display data of the adjustment remote
commander
Measuring Instrument
Adjustment Page
D
Adjustment Address
B5
Specified Value
FF or 00 or 01
Note1:
Note: The two digits of the display data of the LCD and TV monitor
is the object data.
 HI XX XXXX
Object data
Note2:
Perform “CR AD Clamp Adjustment” before this adjustment.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 11, set data: 24, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 2, address: 96, and set data: 40.
4)
Select page: 2, address: 97, and set data: 18.
5)
Select page: D, address: B5, change the data and adjust the
DDS display data (or the display data of page: 2, address: 1E)
to the specified value. (The data of address: B5 should be “00”
to “99”.)
6)
Press the PAUSE button of the adjustment remote commander.
Processing after Completing Adjustments
1)
Select page: D, address: 11, set data: 00, and press the PAUSE
button of the adjustment remote commander.
2)
Select page: 0, address: 01, and set data: 00.
3)
Select page: 2, address: 96, and set data: 00.
4)
Select page: 2, address: 97, and set data: 00.
Page of 127