Sony KV-HG29M80 Service Manual ▷ View online

– 16 –
KV-HG29M50,M60/L,M64K/L,M80,M86K/L,N60
RM-GA002
2-30.  Cap Assy, High Voltage installation
2-31.  HV cap assy wire dressing
Install Cap Assy, High Voltage as shown.
TVSR Requirement:
1. Keep HV cable away from conductive
 parts 
(distance 
of 
1mm/kV).
2. Keep spacing between edge of anode
  cap & conductive parts (distance of
 0.5mm/kV).
3. Keep spacing between edge of anode
  cap & non-conductive parts
  (distance of at least 5mm or more).    
TVSR Requirement:
1. Spacing between HV cable and other conductive part’s surface is 1mm/kV or more.
2. Spacing between HV cable's and enclosure with ventilation or the edge where terminal bracket and rear cover meet: 10 mm or more.
Keep distance of
0.5mm/kV 
Keep distance of
1mm/kV 
DGC
HV Cap
90º
DGC Band
Rotation coil
>5mm
Caution: 1) Make sure the specified position is being followed.
              2) Position the Cap Assy, High Voltage in the inner ring of the Holder, HV cable combi (see diagram).
DGC
CRT's carbon area
HV cap
90º
Min. distance = 1mm/kV
Keep distance of 
HV cable from 
other wires, 
conductive parts 
and CRT's carbon 
area    
Min. distance = 1mm/kV
CRT's carbon area
Holder, HV cable combi
DGC
Inner 
230 ± 5 mm
Dress Holder, HV Cable Combi 
to Cap Assy, High Voltage 
CAUTION:
Production side please ensure that the 
portion of HV cable above the Holder, HV 
Cable Combi is kept away from CRT's 
carbon area.
Also, portion of HV cable below the Holder, 
HV Cable Combi needs to be kept away 
from conductive parts (DGC, rotation coil, 
CRT's carbon area, speaker wire,
etc).
Ensure forming of HV cable is OK and no 
unnatural curve occurs. Do not twist or 
loop the cable.
Dress Cap Assy, High Voltage with Holder, HV cable combi as shown.
– 17 –
KV-HG29M50,M60/L,M64K/L,M80,M86K/L,N60
RM-GA002
2-32.  AC Power Cord Wire Dressing (HG29 Non-PiP)
2-33.  AC Power Cord Wire Dressing (HG29 PiP models)
Install AC cord holder to AC power cord at specified position as shown.
Hook AC cord into CRT
support's hook
Dress behind boss
Beznet
CAUTION
POINT 
Make sure AC cord is behind beznet and
above mounted boards when docking
chassis --> avoid it from being trapped
between chassis and beznet   
Attach AC cord onto
holder and insert to
bottom cover  
Make sure AC cord is
straight between boss
and holder  
Attach Purse Lock (S)
Ø 8 in to rear cover
 
630 ± 5mm 
Install AC cord holder to AC power cord at specified position as shown.
Hook AC cord into CRT support's hook 
Dress behind boss
Attach AC cord onto holder and
insert to bottom cover 
Make sure AC cord is straight
between boss and holder 
Attach Purse Lock (S)
Ø 8 in to rear cover
 
Beznet
CAUTION
POINT 
Make sure AC cord is behind
beznet and above mounted
boards when docking chassis -->
avoid it from being trapped
between chassis and beznet    
650 ± 5mm 
– 18 –
KV-HG29M50,M60/L,M64K/L,M80,M86K/L,N60
RM-GA002
The following adjustments should be made when a complete
realignment is required or a new picture tube is installed.
The controls and switch should be set as follows unless
otherwise noted:
Picture Control....................................."NORMAL"
Brightness Control..............................."NORMAL"
Perform the adjustments in order as follows :
1. Beam Landing
2. Convergence
3. Focus
4. G2(SCREEN)
5. White Balance
Note : Test Equipment Required.
1. Pattern Generator
5. Oscilloscope
2. Degausser
6. Landing Checker
3. DC Power Supply
7. XCV Adjuster
4. Digital Multimeter
SECTION 3
SET-UP ADJUSTMENTS
Preparation :
• Feed in the white pattern signal.
• Before starting, degauss the entire screen with the
degausser.
• In order to reduce the geomagnetism on the set's picture
tube, face it east or west.
3-1. BEAM LANDING ADJUSTMENT
1. Input a raster signal with the pattern generator.
2. Loose the deflection yoke(DY) mounting screw, and set
the purity control to the center as shown below:-
3. Position VM coil as shown below:-
4. Set the raster signal of the pattern generator to green.
5. Move the DY backward and adjust the purity control so
that green is in the center and blue and red are at the
sides evenly.
Red
Blue
Green
a
b
b
c
c
d
d
a
Purity control
corrects this area.
Disc magnets or rotatable
disc magnets correct these
areas (a-d).
Deflection yoke positioning
corrects these areas.
Purity control
VM coil
G2
G1
G3
Align the edge of
the VM coil with
the edge of the G3 grid.
G4
......................................................................................................................................................................................................................
6. Then move the DY forward and adjust so that the entire
screen becomes green.
7. Now switch over raster signal to red then blue and
confirm the condition.
8. When the position of the DY is determined, tighten it with
the DY mounting screw.
9. If the beam does not land correctly in all the corners of
the screen, use magnet disc to correct it.
– 19 –
KV-HG29M50,M60/L,M64K/L,M80,M86K/L,N60
RM-GA002
Moved RV750 (H.STAT)
R
R
G
G
B
B
A
A
B
B
B
B
R
G
G
R
B
3-2. CONVERGENCE ADJUSTMENT
Preparation:
• Before starting, perform FOCUS adjustment.
• Picture Mode "CUSTOM"
• Receive dot/cross hatch pattern.
1. (Moving vertically), adjust the 4 pole magnet to
converge red, green and blue dots in the center of
the screen.
2. Tilt the 4 pole magnet and adjust static convergence
to open or close the 4 pole magnet.
3. When the 4 pole magnet is moved in the direction of
arrow A and B, the red, green and blue dots moves
as shown below:-
a) Vertical Static Convergence
b) Horizontal Static Convergence
If the blue dots does not converge with the red and
green dots, use the 6 pole magnet to adjust in
the manner described below:-
c) Y Separation axis correction magnet adjustment.
1. Receive cross hatch signal.
2. Set Picture to "MINIMUM", Brightness to "STANDARD".
3. Adjust the Y separation axis correction magnet on
the Neck Assembly so that the horizontal lines at
the top and bottom of the screen are straight.
Red
Blue
Red
Blue
6 Pole Magnet
4 pole Magnet
DY pocket
Purity
6 Pole
Magnet
4 Pole
Magnet
R G
B
R
G
B
R
G B
R
B
R
G
G
G
B
R
B
4 pole magnet
RV750
H. STAT
RV1800
G2 (SCREEN) 
Center dot
R     G     B
G
R
B
Page of 91
Display

Click on the first or last page to see other KV-HG29M80 service manuals if exist.