– 12 –
KV-HG29M50,M60/L,M64K/L,M80,M86K/L,N60
RM-GA002
2-18.  P board Wire Dressing (HG PiP models)
2-19.  A board Wire Dressing (HG PiP models)
2-20.  P board Wire Dressing (HG PiP models)
1) Insert Conn Assy, 6P AFT from A board into CN1417 on P board.
2) Dress Conn Assy, 3P SCL (Red) from K board, around CN1417 and to the left of tuner on P board.
3) Insert Conn Assy, 3P SCL (Red) into CN1410 on P board.
4) Insert Conn Assy, 6P Karaoke (Red) from K board into CN1401 on P board.
1) Dress Conn Assy, 5P YUV and Lead Assy, Earth together using purse lock Ø 5.
2) Insert P-P cable into tuner on A board.
3) Dress Conn Assy, 6P Karaoke (White) using pin, wire A017.
1) Insert Conn Assy, 5P YUV from CN007 on A board into CN1403 on P board.
2) Insert Conn Assy, 6P YUVS from CN1405 (P board) to CN906 (A board).
3) Dress wires together using pin, wire A019 as shown in diagram.
3
CN1410
CN1401
4
Conn Assy, 6P Karaoke
(Red) along the center line 
center line
5
CN1406
CN907
1
CN1417
CN607
CN8209
Tuner
Conn Assy, 3P SCL (Red) 
to the left of tuner  
2
Conn Assy, 4P PIP
Conn Assy, 6P AFT
Conn Assy, 6P AFT
Conn Assy, 3P SCL
1
Lead Assy, Earth
Conn Assy, 5P YUV
Purse lock Ø 5 
P-P cable
Tuner
(A board) 
Wires are all
underneath P-P cable 
Pin, wire A017
Conn Assy, 6P
Karaoke (White) 
3
2
Lead Assy, Earth
Conn Assy, 5P YUV
Purse lock 
Ø
 5
Conn Assy, 6P
Karaoke (White) 
Pin, wire A017
CN1405
CN906
Conn Assy, 6P YUVS
Conn Assy, 5P YUV
CN007
CN140
1
2
Pin, wire A019
Conn Assy, 6P YUVS
3
Conn Assy, 6P
Karaoke (RED) 
Conn Assy, 6P AFT
Conn Assy, 5P YUV
Conn Assy, 6P AFT
Conn Assy, 5P YUV
Conn Assy 6P, Karaoke (RED)
Conn Assy, 6P YUVS
Conn Assy, 4P PIP
Pin, wire A019
Conn Assy, 4P PIP
– 13 –
KV-HG29M50,M60/L,M64K/L,M80,M86K/L,N60
RM-GA002
2-21.  P board Installation (HG PiP models)
2-22.  Connector Assy wire dressing (HG non-PiP)
2-21.  P board Installation (HG PiP models)
2-23.  DY Connector Assy wire dressing 
 (HG 
non-PiP)
2-24.  Connector Assy wire dressing 
 
(HG PiP models)
1) Dress Conn Assy, 4P PIP; Conn Assy, 5P YUV; Conn Assy, 6P YUVS and Conn Assy, 3P SCL (Red) using purse lock Ø 5
2) Ensure Conn Assy, 3P SCL (Red) is above surface of K board (avoid getting trapped beneath K board).
Dress Conn Assy, 7P RGB; Conn Assy, 5P Video2 and Lead Assy, Earth using 
purse lock Ø 9. Keep wires away from heatsinks and 
high-temperature parts.
Conn Assy, 5P YUV
Conn Assy, 4P 
Conn Assy, 3P SCL 
Keep wires away from
heatsink A1403 
1
Conn Assy, 6P YUVS
Purse lock Ø 5 
Conn Assy, 3P SCL (Red)
2
Conn Assy, 6P YUVS
Conn Assy, 3P SCL (Red)
Conn Assy, 4P PIP
Conn Assy, 5P YUV
Purse lock 
Ø
 5
Lead Assy, Earth
CN004
Lead Assy, Earth is behind
Conn Assy, 7P RGB 
Lead Assy, Earth
Conn Assy, 5P Video2
Conn Assy, 7P RGB
Purse lock 
Ø
 9
Keep Conn Assy, 5P Video2 wire in an upward path
from CN9201 to where it is dressed with purse lock 
Ø 9. This is to keep it away from deflection area.  
Conn Assy, 5P Video2
Conn Assy, 7P RGB
Make loop of Conn Assy, 7P RGB as large as
possible when dressing with purse lock 
Dress DY Connector; Conn Assy, 4P 200V;
Conn Assy 4P VM and Conn Assy, 6P using purse lock Ø 5 as shown. 
i) Dress Conn Assy, 7P RGB; Conn Assy, 5P Video2; Lead Assy, Jumper and
   lead Assy, Earth using purse lock Ø 9. 
 
Note: Make sure DY connector is inserted securely --> prevent it from coming out.
Conn Assy, 6P
DY Conn
Conn Assy, 4P VM
Dress purse lock Ø 5 by using
height of heatsink as a guide
 
Conn Assy,
4P 200V 
Use height of 
heatsink as a guide 
Keep Conn Assy, 4P 200V
away from FBT (min. 10mm) 
DY Connector
Conn Assy, 6P
Conn Assy, 4P 200V
Purse lock Ø 5 
Conn Assy, 4P VM
Conn Assy, 7P RGB
Lead Assy, Earth
Purse lock Ø 9 
CN004
Conn Assy, 5P Video2
Lead Assy, Earth is behind
Conn Assy, 7P RGB 
Lead Assy, Jumper
– 14 –
KV-HG29M50,M60/L,M64K/L,M80,M86K/L,N60
RM-GA002
2-26.  Overall view of rotation coil conn
2-27.  Overall view of Lead Assy, G2; Lead Assy, Focus and Rotation Coil Conn Dressing
2-24. Connector Assy wire dressing 
 
(HG PiP models)
2-25.  DY Connector Assy wire dressing 
 
(HG PiP models)
ii) Keep wires away from heatsinks and high-temperature parts.
Dress DY Connector; Conn Assy, 4P 200V;
Conn Assy 4P VM and Conn Assy, 6P using purse lock Ø 5 as shown.
 
Make sure DY connector
is inserted securely.
--> prevent it from coming 
out.
Lead Assy, Earth
Conn Assy, 5P Video2
Conn Assy, 7P RGB
Lead Assy, Jumper
Purse lock 
Ø  
Keep Conn Assy, 5P Video2 and Lead Assy,
Jumper in a straight path to where it is dressed
with purse lock Ø 9. This is to keep it away from
deflection area.
Lead Assy, Jumper
DY Conn
Conn Assy, 4P VM
Dress purse lock Ø 5
using height of heatsink 
as a guide 
 
Conn Assy,
4P 200V 
Use height of 
heatsink as a guide 
Keep Conn Assy, 4P 200V
away from FBT (min. 10mm) 
DY Connector
Conn Assy, 6P
Conn Assy, 4P 200V
Purse lock Ø 5 
Conn Assy, 4P VM
Conn Assy, 5P
Video2 
Conn Assy, 6P
Install Rotation Coil as shown.
1) Coil positioned in clockwise direction.
2) Wire is at 3 o'clock position.
Rotation coil conn is dressed outside
and below Earth Assy, Coating wires. 
Earth Assy,
Coating wires 
Rotation Coil
DY
CAUTION:
Prevent wires from touching rear cover or any enclosures 
by turning them away from it --> avoid rattle sound. 
Wire from 
Rotation Coil 
Avoid any stress on Lead Assy, G2; Lead Assy, Focus and terminal at W7001.
Dress Rotation Coil 
connector together with 
Lead Assy, G2; Lead Assy 
Focus and Conn Assy, 
4P 200V using pin, wire A707  
Rotation Coil Conn
Lead Assy, G2
W7001
CN1802
Keep wire away from 
R781 and heatsinks 
A713, A715. 
Conn Assy, 4P 200V
Lead Assy,
Focus 
A715
A713
Keep wire away
 from R781
– 15 –
KV-HG29M50,M60/L,M64K/L,M80,M86K/L,N60
RM-GA002
2-28.  Lead Assy, Speaker Dressing (all HG29 models)
2-29.  Dress Lead Assy, Speaker DGC
Dress Lead Assy, Speaker as shown. Keep capacitor from touching metal area on CRT.
Right Speaker
Left Speaker
Keep capacitor on Lead Assy, 
Speaker away from metal area of CRT
--> to avoid short circuit   
Lead Assy, Speaker
(WHT+BLK) 
Lead Assy, Speaker
(RED+BLK) 
Lead Assy, Speaker
(RED+BLK) 
Lead Assy, Speaker
(RED+BLK) 
Earth Assy, Coating wire is 
above DGC 
Lead Assy, Speaker 
Earth Assy, 
Coating wire 
Purse lock Ø 9 
Lead Assy, Speaker
DGC Conn
DGC
Dress Lead Assy, Speaker, DGC
Conn and DGC  together using
Purse lock Ø 9  
Purse lock Ø 9 
DGC
Lead Assy, Speaker
Dress Lead Assy, Speaker, and DGC  
together  using Purse lock Ø 9  
DGC
Lead Assy, Speaker 
Purse lock 
Ø
 9
DGC Conn
DGC
Lead Assy, Speaker
Purse lock 
Ø
 9
Dress Lead Assy, Speaker along surface of CRT to DGC as shown. Make sure Earth Assy, Coating wire is above DGC.
i)
ii)
Page of 91