Sony KLV-40W300A / KLV-46W300A Service Manual ▷ View online

KLV-40/46W300A (WB)     3-5
NO
2 Times
YES
See  
3-3-2. POWER OVP
(RED 2 times blink)
RED LED Blinks
NO
3 Times
YES
See  
3-3-3. POWER ERROR
(RED 3 times blink)
NO
5 Times
YES
See  
3-3-4. T-CON ERROR
 (RED 5 times blink)
NO
6 Times
YES
See  
3-3-5. BACK LIGHT ERROR 
(RED 6 times blink)
NO
7 Times
YES
See  
3-3-6 TEMP ERR
(RED 7 times blink)
NO
8 Times
YES
See  
3-3-7 AUDIO ERROR
(RED 8 times blink)
13 Times
YES
See  
3-3-9. BALANCER ERROR
(RED 13 times blink)
3-3-1. Flow Chart_C  
(Standby Indicator)
KLV-40/46W300A (WB)     3-6
This indicates POWER Error, Low B error of 12V from GF1(GF2) board. TV Micro
(on AG board) pin150 detects POWER_ERR and shuts down chassis power to Stand-
by status.
TV Micro #150
Normal condition : High  /   Error case : Low
- Check 12V at CN002 #1#2 on AG board. And F200 on AG has 12V or not
- Check GF1(GF2) board.
3-3-3. POWER ERROR (RED 3 Times blink) 
This indicates OVP (Over Voltage Protection) of GF1(GF2) board.
12V line or 6.5Vline on GF1(GF2) board is over-voltage.
TV Micro (on AG board) pin139 detects OVP ERR and shuts down chassis power to
 
Stand-by status.
TV Micro #139
Normal condition : Low  /   Error case : High
Replace GF1(GF2) board.
3-3-2. POWER OVP (RED 2 Times blink) 
KLV-40/46W300A (WB)     3-7
This indicates panel power circuit error such as inverter.
BE micro pin 78 on FB2 board detects it.
BE Micro #78
Normal condition : High  /   Error case : Low
Replace DF boards.
3-3-5. BACK LIGHT ERROR (RED 6 Times blink) 
This indicates T-CON RDY signal error from timing controller of Panel module.
BE micro pin 128 on FB2 board detects it.
BE Micro #128
Normal condition : High  /   Error case : Low
Replace Panel module.
3-3-4. T-CON ERROR (RED 5 Times blink) 
KLV-40/46W300A (WB)     3-8
This indicates Audio Error (Protection). It happens;
- IC8806 on AG board, Audio Amp detects over current, thermal shut down and/or low
voltage of itself.
- DC voltage detected for speaker line.
Check above and replace AG board
3-3-7. AUDIO ERROR (RED 8 Times blink) 
This indicates high temperature inside chassis. IC001 on AG Board Side is monitoring
temperature. IC001 is controlled by BEM I2C.
When it happens;
- Check chassis environment
- Check around IC001 and replace AG if temperature monitoring circuit has problem
- Check panel
3-3-6. TEMP ERROR (RED 7 Times blink) 