Sony KLV-40W300A / KLV-46W300A Service Manual ▷ View online
KLV-40/46W300A (WB) 3-5
NO
2 Times
YES
See
3-3-2. POWER OVP
(RED 2 times blink)
3-3-2. POWER OVP
(RED 2 times blink)
RED LED Blinks
NO
3 Times
YES
See
3-3-3. POWER ERROR
(RED 3 times blink)
3-3-3. POWER ERROR
(RED 3 times blink)
NO
5 Times
YES
See
3-3-4. T-CON ERROR
(RED 5 times blink)
3-3-4. T-CON ERROR
(RED 5 times blink)
NO
6 Times
YES
See
3-3-5. BACK LIGHT ERROR
(RED 6 times blink)
3-3-5. BACK LIGHT ERROR
(RED 6 times blink)
NO
7 Times
YES
See
3-3-6 TEMP ERR
(RED 7 times blink)
3-3-6 TEMP ERR
(RED 7 times blink)
NO
8 Times
YES
See
3-3-7 AUDIO ERROR
(RED 8 times blink)
3-3-7 AUDIO ERROR
(RED 8 times blink)
13 Times
YES
See
3-3-9. BALANCER ERROR
(RED 13 times blink)
3-3-9. BALANCER ERROR
(RED 13 times blink)
3-3-1. Flow Chart_C
(Standby Indicator)
KLV-40/46W300A (WB) 3-6
This indicates POWER Error, Low B error of 12V from GF1(GF2) board. TV Micro
(on AG board) pin150 detects POWER_ERR and shuts down chassis power to Stand-
by status.
(on AG board) pin150 detects POWER_ERR and shuts down chassis power to Stand-
by status.
TV Micro #150
Normal condition : High / Error case : Low
- Check 12V at CN002 #1#2 on AG board. And F200 on AG has 12V or not
- Check GF1(GF2) board.
3-3-3. POWER ERROR (RED 3 Times blink)
This indicates OVP (Over Voltage Protection) of GF1(GF2) board.
12V line or 6.5Vline on GF1(GF2) board is over-voltage.
TV Micro (on AG board) pin139 detects OVP ERR and shuts down chassis power to
Stand-by status.
TV Micro #139
Normal condition : Low / Error case : High
Replace GF1(GF2) board.
3-3-2. POWER OVP (RED 2 Times blink)
KLV-40/46W300A (WB) 3-7
This indicates panel power circuit error such as inverter.
BE micro pin 78 on FB2 board detects it.
BE micro pin 78 on FB2 board detects it.
BE Micro #78
Normal condition : High / Error case : Low
Replace DF boards.
3-3-5. BACK LIGHT ERROR (RED 6 Times blink)
This indicates T-CON RDY signal error from timing controller of Panel module.
BE micro pin 128 on FB2 board detects it.
BE Micro #128
Normal condition : High / Error case : Low
Replace Panel module.
3-3-4. T-CON ERROR (RED 5 Times blink)
KLV-40/46W300A (WB) 3-8
This indicates Audio Error (Protection). It happens;
- IC8806 on AG board, Audio Amp detects over current, thermal shut down and/or low
voltage of itself.
voltage of itself.
- DC voltage detected for speaker line.
Check above and replace AG board
3-3-7. AUDIO ERROR (RED 8 Times blink)
This indicates high temperature inside chassis. IC001 on AG Board Side is monitoring
temperature. IC001 is controlled by BEM I2C.
temperature. IC001 is controlled by BEM I2C.
When it happens;
- Check chassis environment
- Check around IC001 and replace AG if temperature monitoring circuit has problem
- Check panel
3-3-6. TEMP ERROR (RED 7 Times blink)
Click on the first or last page to see other KLV-40W300A / KLV-46W300A service manuals if exist.