Sony KE-42TS2E / KE-42TS2U Service Manual ▷ View online
6
(4)
Connector Specifications
The connector specification is shown below. Please do not connect anything with
the terminal NC.
(ⅰ)Signal connector CN1: DF13-20DP-1.25 V (tin-plated) (Maker: HIROSE DENKI)
Pin No.
Signal name
Pin No.
Signal name
1 RXIN0- 2 GND
3 RXIN0+ 4
SCL
5 RXIN1- 6 GND
7 RXIN1+ 8 SDA
9 RXIN2- 10 GND
11 RXIN2+ 12 CPUGO
13 RXCLKIN- 14 PDPGO
15 RXCLKIN+ 16 IRQ
17 RXIN3- 18 PDWN
19 RXIN3+ 20 GND
[Conforming connector]
Housing: DF13-20DS-1.25C
Contact: DF13-2630SCF
(ⅱ)Power Source Connectors(Only UB-01 Type)
(a)Power input connector (b)Power supply output connector for system
CN61:B06P-VH
CN62:B03P-VH
(Maker: JST) (Maker: JST)
Pin No.
Symbol
Pin No.
Symbol
1 AC(L)
1
V
AUX
2 N.C
2 N.C
3 AC(N)
3 GND
4 N.C
5
N.C
6 F.G
[Conforming connector]
Housing:VHR-06N(or M)
Contact:SVH-21T-P1.1
(c)Power supply output connector for system
CN63:B5B-XH-A
(Maker: JST)
Pin No.
Symbol
1 Vpr1
2 N.C.
3 Vpr2
4 N.C.
5 GND
2 N.C.
3 Vpr2
4 N.C.
5 GND
[Conforming connector]
Housing:XHP-5
Contact:SXH-001T-P0.6
[Conforming connector]
Housing:VHR-03N(or M)
Contact:SVH-21T-P1.1
7
(ⅲ)
Power Source Connectors
(a)
Power supply output
(b)
Power supply output
(c)
Power supply output
connector for system
connector for system
connector for system
CN6: B6B-PH-SM3-TB(JST) CN23: B10P-VH(JST) CN33: B9PS-VH(JST)
Pin No.
Symbol
Pin No.
Symbol
Pin No.
Symbol
1 Vpr2
1 Va
1 Vcc
2 N.C.
2 N.C.
2 GND
3 GND
3 Vcc
3 GND
4 GND
4 GND
4 GND
5 N.C.
5 GND
5 GND
6 Vcc
6 GND
6 N.C.
7 N.C.
7 Vs
8 Vs
8 Vs
9 Vs
9 Vs
10 Vs
(d)
Power supply output
(e)
Power supply output
connector for system
connector for system
CN42: S7B-PH-SM3-TB(JST) CN52: S7B-PH-SM3-TB(JST)
Pin No.
Symbol
Pin No.
Symbol
1 Va
1 Va
2 N.C.
2 N.C.
3 N.C.
3 N.C.
4 GND
4 GND
5 GND
5 GND
6 N.C.
6 N.C.
7 Vcc
7 Vcc
(f)
Power supply output
connector for system
CN7: 00 6200 520 330 000 [ZIF Right Angle Connector](kyousera elco)
Pin No.
Symbol
Pin No.
Symbol
1 N.C. 11 GND
2 N.C. 12 Vra
3 N.C. 13 GND
4 N.C. 14 Vrs
5 GND 15 GND
6 VSAGO 16 Iak
7 GND 17 GND
8 VCEGO 18 Vak
9 GND 19 GND
2 N.C. 12 Vra
3 N.C. 13 GND
4 N.C. 14 Vrs
5 GND 15 GND
6 VSAGO 16 Iak
7 GND 17 GND
8 VCEGO 18 Vak
9 GND 19 GND
10 PFCGO 20 Vsk
[Conforming connector]
Housing:PHR-6
Contact:SPH-002T-P0.5L
Contact:SPH-002T-P0.5L
[Conforming connector]
Housing:VHR-10N
Contact:SVH-21T-
Contact:SVH-21T-
P1.1
[Conforming connector]
Housing:VHR-9N
Contact:SVH-21T-P1.1
Contact:SVH-21T-P1.1
[Conforming connector]
Housing:PHR-7
Contact:SPH-002T-P0.5L
Contact:SPH-002T-P0.5L
[Conforming connector]
Housing:PHR-7
Contact:SPH-002T-P0.5L
Contact:SPH-002T-P0.5L
8
2.
Notes on safe handling of the plasma display
2. 1
Notes to follow during servicing
The work procedures shown with the Note indication are important for ensuring the safety of
the product and the servicing work. Be sure to follow these instructions.
the product and the servicing work. Be sure to follow these instructions.
Before starting the work, secure a sufficient working space.
At all times other than when adjusting and checking the product, be sure to turn OFF the main
POWER switch and disconnect the power cable from the power source of the display (jig or the
display itself) during servicing.
POWER switch and disconnect the power cable from the power source of the display (jig or the
display itself) during servicing.
To prevent electric shock and breakage of PC board, start the servicing work at least 30 seconds after
the main power has been turned off. Especially when installing and removing the power supply PC
board and the SUS PC board in which high voltages are applied, start servicing at least 2 minutes
after the main power has been turned off.
the main power has been turned off. Especially when installing and removing the power supply PC
board and the SUS PC board in which high voltages are applied, start servicing at least 2 minutes
after the main power has been turned off.
While the main power is on, do not touch any parts or circuits other than the ones specified.
The high voltage power supply block within the PDP module has a floating ground. If any
connection other than the one specified is made between the measuring equipment and the
high voltage power supply block, it can result in electric shock or activation of the
leakage-detection circuit breaker.
connection other than the one specified is made between the measuring equipment and the
high voltage power supply block, it can result in electric shock or activation of the
leakage-detection circuit breaker.
When installing the PDP module in, and removing it from the packing carton, be sure to have at least
two persons perform the work while being careful to ensure that the flexible printed-circuit cable of the
PDP module does not get caught by the packing carton.
two persons perform the work while being careful to ensure that the flexible printed-circuit cable of the
PDP module does not get caught by the packing carton.
When the surface of the panel comes into contact with the cushioning materials, be sure to confirm
that there is no foreign matter on top of the cushioning materials before the surface of the panel
comes into contact with the cushioning materials. Failure to observe this precaution may result in
the surface of the panel being scratched by foreign matter.
that there is no foreign matter on top of the cushioning materials before the surface of the panel
comes into contact with the cushioning materials. Failure to observe this precaution may result in
the surface of the panel being scratched by foreign matter.
When handling the circuit PC board, be sure to remove static electricity from your body before
handling the circuit PC board.
handling the circuit PC board.
Be sure to handle the circuit PC board by holding the such large parts as the heat sink or
transformer. Failure to observe this precaution may result in the occurrence of an abnormality in
the soldered areas.
transformer. Failure to observe this precaution may result in the occurrence of an abnormality in
the soldered areas.
Do not stack the circuit PC boards.
Failure to observe this precaution may result in problems resulting from scratches on the parts, the
deformation of parts, and short-circuits due to residual electric charge.
deformation of parts, and short-circuits due to residual electric charge.
Routing of the wires and fixing them in position must be done in accordance with the original
routing and fixing configuration when servicing is completed.
routing and fixing configuration when servicing is completed.
All the wires are routed far away from the areas that become hot (such as the heat sink). These
wires are fixed in position with the wire clamps so that the wires do not move, thereby ensuring
that they are not damaged and their materials do not deteriorate over long periods of time.
Therefore, route the cables and fix the cables to the original position and states using the wire
clamps.
wires are fixed in position with the wire clamps so that the wires do not move, thereby ensuring
that they are not damaged and their materials do not deteriorate over long periods of time.
Therefore, route the cables and fix the cables to the original position and states using the wire
clamps.
Perform a safety check when servicing is completed.
Verify that the peripherals of the serviced points have not undergone any deterioration during
servicing. Also verify that the screws, parts and cables removed for servicing purposes have
all been returned to their proper locations in accordance with the original setup.
servicing. Also verify that the screws, parts and cables removed for servicing purposes have
all been returned to their proper locations in accordance with the original setup.
9
3
3
3
3.
.
.
.
Name and Function
Name and Function
Name and Function
Name and Function
3.1 Configuration
The figure shows the article number in the parts information table of clause 7.
*1:Power supply(jig)
①LOGIC board
④ABUSL board
⑤ABUSR board
②X-SUS board
③Y-SUS board
⑥PSU board *1
Scan module
Panel chassis
Serial Id label
Serial Id label
XBB
⑧Ps cable
⑩PSU
Signal
Signal
Address module(ADM)
Product label
⑪Signal
cable
cable
⑩Signal
cable
cable
⑨Signal
cable
cable
ADM1
ADM2
ADM3
ADM4
ADM5
ADM6
ADM7
ADM8
Click on the first or last page to see other KE-42TS2E / KE-42TS2U service manuals if exist.