Sony KE-42TS2E / KE-42TS2U Service Manual ▷ View online
14
Setting [hex]
Sub
Address
Data
bit
Symbol
Item
Function
RANGE
INITIAL value
1 PDPON
High voltage
power supply
ON
ON
Switches ON/OFF the high voltage power
supply of PDP.
0: Power OFF
1: Power ON
1: Power ON
0
0
Be sure to use the display with the setting
fixed to 1.
0~1 1
7-5
-
-
Be sure to use the display with the setting
fixed to 0.
0~7
1【UB0x/5x】
7-6
-
-
Be sure to use the display with the setting
fixed to 0.
0~7 0【UB7x】
4 CCFMD
Color
correction
mode
Selecting the color correction modes.
Valid when the CCFON setting is 1
0: Luminance
has priority.
1: Gradation has
priority
0【UB7x】
3 DCBON
Dynamic
Color Balance
Tracking correction of white balance
between the high luminance and the low
luminance.
0: OFF
1: ON
1: ON
0
2 HAON
Heat APC
function
When a picture with high
luminance/small area is displayed for
about 3 minutes or longer, the number of
pulses is reduced to about 20% at a
maximum. This item can be used to
reduce panel temperature/extend useful
life when the display is used to show a
still image.
0: OFF
1: ON
1: ON
0
1
-
-
Be sure to use the display with the setting
fixed to 0.
0~1 0
21
0 DSETEN
Data
set
enable
Whether the register value is reflected to
the operating status of this product,
selected by this item.
The following switch is executed.
0: The received register value is reflected
The following switch is executed.
0: The received register value is reflected
from the next field.
1: The received register value is stored so
that the DSET setting is reflected from
the next field.
(DSET setting: Setting bit 0 of address
FF)
0: Invalid
1: Valid
1: Valid
1
7 CCFON
Color
correction
Color collection process is turned
ON/OFF.
0: OFF
1: ON
1: ON
0
6 CCFORM
Color
correction
format
Color collection process is switched.
This item is valid when CCFON setting is
This item is valid when CCFON setting is
1.
0: NTSC
1: EBU
1: EBU
0
5-3
-
-
Be sure to use the display with the setting
fixed to 0.
0~7 0
22
2-0 GAMSEL
Selecting the
reverse γ
correction
Reverse γ correction level is set.
The setup 7 is the test mode. Do not select
The setup 7 is the test mode. Do not select
the setup 7.
When the setup 6 is selected, setting of
When the setup 6 is selected, setting of
the addressed in the range of 31~51
become valid.
0: OFF
1: 1.0 th power
1: 1.0 th power
2: 2.2 nd power
3: 2.4 th power
4: 2.6 th power
5: 2.8 th power
6: USER
7: TEST
3: 2.4 th power
4: 2.6 th power
5: 2.8 th power
6: USER
7: TEST
2
15
Setting [hex]
Sub
Address
Data
bit
Symbol
Item
Function
RANGE
INITIAL value
23
7-0 CONTrast
Peak
luminance
Peak luminance is adjusted.
When the display picture load is heavy,
When the display picture load is heavy,
the peak luminance is automatically
limited.
00~FF
FF
24 7-0
R-RATIO R
ratio
00~FF
FF
25 7-0
G-RATIO G
ratio
00~FF
FF
26 7-0
B-RATIO B
ratio
White balance is adjusted.
Use the display with at least one item
Use the display with at least one item
being set to FF (hex).
00~FF FF
7 IRQRST
Clearing the
IRQ output
signal
This item implements control to return the
IRQ signal from "HIGH" to "Low" level
when an error occurs. When this item is
set to 1, the IRQ signal is returned to
"Low" level.
0: Normal
1: IRQ signal
1: IRQ signal
clear
0
6 ERRRST
Clearing the
ERRF flag
This item implements control to return the
ERRF flag to 0 when an error occurs.
When this item is set to 1, this setting
When this item is set to 1, this setting
automatically returns to 0 after returning
the ERRF flag to 0.
0: Normal
1: ERRF
1: ERRF
flag
clear
0
5
-
-
Be sure to use the display with the setting
fixed to 0.
0~1
0【UB0x/5x】
5 OHRRST
Clearing the
OHRF flag
The control by which the OHRF flag is
returned to 0 is done. This setting
automatically returns to the state of 0 after
returning 0 the ERRF flag when this
setting is set to one.
0: Normal
1: OHRF
1: OHRF
flag clear
0【UB7x】
4
PSDRST
Clearing the
PSDF flag
This item exercise control to return the
PSDF flag to 0 when this machine
performs the OFF sequence at AC power
shutdown.
When this item is set to 1, this setting
When this item is set to 1, this setting
automatically returns to 0 after returning
the PSDF flag to 0.
0: Normal
1: PSDF
1: PSDF
flag
clear
0
27
3-0 ERRS
Error
code
selection
When this setting is changed and the
ERRC setting is read out, the error
contents (as many as 16 errors) of the
module that have occurred in the past can
be checked.
If more than 16 errors have occurred, the
If more than 16 errors have occurred, the
error code is updated starting from the
oldest error.
0: Latest error
1: Previous error
2:
|
E:
F: Oldest error
1: Previous error
2:
|
E:
F: Oldest error
0
7-6
-
-
Be sure to use the display with the setting
fixed to 0.
0~3
0【UB0x/5x】
7
PWMP
Power
Maximam
peek control
The PWMAX setting is switched to
constant brightness (peak electric power)
control. The password setting is necessary
to turn on this setting.
When password
is set
0:OFF 1:ON
0【UB7x】
6
-
-
Be sure to use the display with the setting
fixed to 0.
0-3 0【UB7x】
5-4 PWMAX
Maximum
power
consumption
Sets the maximum power consumption.
Set this item in accordance with the status
Set this item in accordance with the status
of the machine.
Make sure that the respective parts'
Make sure that the respective parts'
temperature/panel temperature stays
within the specifications. If the setting is
set to 3, power consumption increases to a
level exceeding the standard
consumption. Be sure to execute the heat
dissipation design so that respective parts'
temperature/panel temperature stay within
the specifications.
0: -20W
1: -10W
2: ±0W
3: +10W
1: -10W
2: ±0W
3: +10W
2【UB0x/5x】
28
5-4
PWMAX
Maximum
power
consumption
PWMP=
0
Setting of the maximum
electric power.
0: 0W
1: +20W
2: +30W
3:+40W
1: +20W
2: +30W
3:+40W
0【UB7x】
16
Setting [hex]
Sub
Address
Data
bit
Symbol
Item
Function
RANGE
INITIAL value
PWMP=
1
Setting of peak electric
power. Electric power by
which electric power is
permitted in addition to
improve practical brightness
to the maximum electric
power set 3:+10W
0: -40W
1: -20W
2: ±0W
3: +20W
1: -20W
2: ±0W
3: +20W
3-0
-
-
Be sure to use the display with the setting
fixed to 0.
0~F 0
29
7-0
PWM
PASS
PASS
Password of
peak electric
power setting
Password of peak electric power
setting.The password is described to the
delivery specifications. When the
password setting is normally done, the
reading value of the real thing ground
becomes 51.
51: Permission of
PWMP ON
Another:
Prohibition
Prohibition
FF【UB7x】
2C 7-0
PsTPW
Ps-Tank
PoWer
The maximum
electric power
setting:
The maximum
The maximum
over electric
power from
+10W
00-FF 1E【UB7x】
2D
7-0 PsTTM
Ps-Tank
TiMe
Time which can
operate by the
maximum over
electric power
(*10sec)
When the amount of
an over electric power
becomes PsTPW×
PsTTM or less at
PWMP=1, the control
by which brightness is
lowered is done.
00-FF
3C【UB7x】
31 7-0
GAM00
Reverse
γ
correction DC
Sets the input level that implements the
forced 0 [LSB] output.
00~FF 1F
7-2
-
<no use>
-
32
1-0 GAM01[9:
8]
00~FF
00
33 7-0
GAM01[7:
0]
Reverse
γ
coefficient 01
Reverse
γ coefficient value is set.
Input Output value of 8 [LSB]
00~FF 04
7-3
-
<no use>
-
34
2-0
GAM02[10:
8]
00~FF 00
35 7-0
GAM02[7:
0]
Reverse
γ
correction 02
Reverse
γ coefficient value is set.
Input Output value of 16 [LSB]
00~FF 24
7-4
-
<no use>
-
36
3-0 GAM03[11:8]
Reverse
γ
correction 03
Reverse
γ coefficient value is set.
Input Output value of 24 [LSB]
00~FF 00
37 7-0 GAM03
[7: 0]
00~FF
58
7-4
-
<no use>
-
38
3-0
GAM04
[11:
8]
Reverse
γ
correction 04
Reverse
γ coefficient value is set.
Input Output value of 32 [LSB]
00~FF 00
39 7-0 GAM04
[7: 0]
00~FF
A7
7-5
-
<no use>
-
3A
4-0
GAM05
[12:
8]
00~FF 01
7-1 GAM05
[7: 1]
Reverse
γ
correction 05
Reverse
γ coefficient value is set.
Input Output value of 40 [LSB]
3B
0
-
<no use>
-
00~FF
12
7-5
-
<no use>
-
3C
4-0
GAM06
[12:
8]
00~FF 01
3D
7-1
GAM06
[7: 1]
Reverse
γ
correction 06
Reverse
γ coefficient value is set.
Input Output value of 48 [LSB]
00~FF 9A
17
Setting [hex]
Sub
Address
Data
bit
Symbol
Item
Function
RANGE
INITIAL value
0 -
<no use>
-
7-5
-
<no use>
-
3E
4-0
GAM07
[12:
8]
00~FF 02
7-2
GAM07
[7: 2]
Reverse
γ
correction 07
Reverse
γ coefficient value is set.
Input Output value of 56 [LSB]
3F
1-0
-
<no use>
-
00~FF
40
7-5
-
<no use>
-
40
4-0
GAM08
[12:
8]
00~FF 03
7-2
GAM08
[7: 2]
Reverse
γ
correction 08
Reverse
γ coefficient value is set.
Input Output value of 64 [LSB]
41
1-0
-
<no use>
-
00~FF 04
7-6
-
<no use>
-
42
5-0
GAM09
[13:
8]
00~FF 04
7-4
GAM09
[7: 4]
Reverse
γ
correction 09
Reverse
γ coefficient value is set.
Input Output value of 80 [LSB]
43
3-0
-
<no use>
-
00~FF
F0
7-6
-
<no use>
-
44
5-0
GAM11
[13:
8]
00~FF 07
7-4
GAM11
[7: 4]
Reverse
γ
correction 10
Reverse
γ coefficient value is set.
Input Output value of 96 [LSB]
45
3-0
-
<no use>
-
00~FF
60
7-6
-
<no use>
-
46
5-0
GAM11
[13:
8]
00~FF 0A
7-4
GAM11
[7: 4]
Reverse
γ
correction 11
Reverse
γ coefficient value is set.
Input Output value of 112 [LSB]
47
3-0
-
<no use>
-
00~FF
50
7-6
-
<no use>
-
48
5-0
GAM12
[13:
8]
00~FF 0D
7-4
GAM12
[7: 4]
Reverse
γ
correction 12
Reverse
γ coefficient value is set.
Input Output value of 128 [LSB]
49
3-0
-
<no use>
-
00~FF
D0
7-6
-
<no use>
-
4A
5-0
GAM13
[13:
8]
00~FF 16
7-4
GAM13
[7: 4]
Reverse
γ
correction 13
Reverse
γ coefficient value is set.
Input Output value of 160 [LSB]
4B
3-0 -
<no
use>
-
00~FF
A0
7-6
-
<no use>
-
4C
5-0
GAM14
[13:
8]
00~FF 21
7-4
GAM14
[7: 4]
Reverse
γ
correction 14
Reverse
γ coefficient value is set.
Input Output value of 192 [LSB]
4D
3-0
-
<no use>
-
00~FF
E0
7-6
-
<no use>
-
4E
5-0
GAM15
[13:
8]
00~FF 2F
4F
7-4
GAM15
[7: 4]
Reverse
γ
correction 15
Reverse
γ coefficient value is set.
Input Output value of 224 [LSB]
00~FF 90