Sony KDF-46E3000 / KDF-50E3000 Service Manual ▷ View online
KDF-46E3000/50E3000
KDF-46E3000/50E3000
21
WIRE
DRESSING
COMPLETE INTERNAL WIRE DRESSING
KDF-46E3000/50E3000
KDF-46E3000/50E3000
22
Install 3P Fan Connector
from Optical Block to
HARNESS ASSY
Dress 3P Fan Connector to
clips on TOP BRACKET,
OPT(E) as shown
Install 8P connector
from [CE] to [BE]
Install 15P connector
from [CE] to [G]
Dress 15P Connector
to wire pin on [G]
Install 15P connector
from [CE] to [G]
Dress 15P Connector
to wire pin on [G]
Install 20P and 9P connector
from Duct Block Assy to [G]
Install LVDS connector
from [CE] to [BE]
Dress LVDS connector to
clips on Main Brkt
After installing Optical Block route
HARNESS ASSY into clips behind TOP
BRACKET, OPT (E)
HARNESS ASSY into clips behind TOP
BRACKET, OPT (E)
OVERALL ASSEMBLY
KDF-46E3000/50E3000
KDF-46E3000/50E3000
23
Dress 8P connector from [BE] to clips on Main Brkt.
RED Tape should line up with clips. This connector
should be on top of LVDS Connector
Dress 8P connector to clip
under LVDS connector
Secure HARNESS ASSY
with 20 X 40 HIMELON tape
Install Ferrite Clamp
(146908911) to HARNESS
ASSY as shown.
Route Ballast Power as shown and
install to wire holders
Install Ballast Power to [G], install Ferrite Clamp
(146908911) and dress to wire pin on [G] as shown.
Ferrite Clamp must be vertical and
as close to Connector as possible
CRITICAL FOR EMI
CRITICAL FOR EMI
Secure Ballast Power with 20 X 40
HIMELON tape as shown
Route 4P Speaker and 9P HAE connector
as shown before installing Seperator Blk
A
After installing Separator Blk Assy ensure
4P and 9P Connetor are not pinched
between Rear cover and Separator
OVERALL ASSEMBLY (CONTINUED)
KDF-46E3000/50E3000
KDF-46E3000/50E3000
24
Connect 4P Speaker and 9P HAE
connector as shown .
Dress 4P Speaker and 9P HAE connector
to wire holders on Separator Blk Assy
SPEAKER ASSEMBLY