DOWNLOAD Sony RM-PJVW60 / VPL-VW60 Service Manual ↓ Size: 11.3 MB | Pages: 124 in PDF or view online for FREE

Model
RM-PJVW60 VPL-VW60
Pages
124
Size
11.3 MB
Type
PDF
Document
Service Manual
Brand
Device
Projector / E1
File
rm-pjvw60-vpl-vw60.pdf
Date

Sony RM-PJVW60 / VPL-VW60 Service Manual ▷ View online

1-21
VPL-VW60
3. Writing Look Up Table/3D gamma/DDC data
Use the dedicated application “Quick Access” for writing
the data.
Application name: 3Dgamma Quick Access
Filename:
QuickAccess.exe
Version:
7.2 or later
1.
Connect the PC to VW60 with the RS-232C cross
cable.
2.
Turn the power on to the projector.
3.
Double-click on “QuickAccess.exe” to launch the
application.
4.
Select “VPL-VW60” from the [Model] pull-down
menu.
5.
Select “Load” from the [Load/Save] pull-down menu.
6.
Select the data type (3D gamma/Look Up Table/DDC)
from the [3dgm/Lut] pull-down menu.
7.
Click on [Next].
8.
Press the [Browser] button and specify the file to
write.
9.
Click on [Next].
10. Set the COM Port and switch the baud rate to 38400.
11. Click on [Next].
12. When the dialog box appears prompting your confir-
mation, click on [OK].
13. Writing has finished when “Completed.” appears.
14. Click on [End].
* See Technical Memo DPPJ04-044R for more details.
1-6. Upgrading the Software
1. SUB
(1) From the RS-232C terminal
1.
Connect the PC to VW60 with the RS-232C cross
cable.
2.
Double-click on “Flash.exe” to launch the application.
Application name: Main Flash upgrader Ver1.04
Filename:
Flash.exe
3.
Select the download information file, and specify the
Main software to write.
Selected file: qh4vxxxx.dil (xxxx is software version)
4.
Place the projector in standby state.
5.
Click the [Start] button in the application.
* See Technical Memo DPPJ04-040 for more details.
2. Scan Converter
(1) From the RS-232C terminal
1.
Connect the PC to VW60 with the RS-232C cross
cable.
2.
Place the projector in standby state.
3.
Start the upgrade application (double-click on
“FlashUpgraderForSony3.5.exe”) for the scan convert-
er (Pixelworks).
Application name: Pixelworks ImageProcessor SDK
FlashUpgrader
Filename:
FlashUpgraderForSony3.5.exe
<Writing the software to scan converter>
4.
Set the COM Port and switch the baud rate to 115200.
5.
Click the [choose...] button in the application and
select the file to write (“pwOpxxxx.inf”).
6.
Click on [Ext_232C PW_1] in the application.
7.
Click the [Flash] button in the application.
8.
Click the [Close] button to end the application.
* See Technical Memo DPPJ03-064 for more details.
1-22
VPL-VW60
1-7. Memory
Memory structure consists of the following memory
blocks.
1.
Set memory
2.
Status memory
3.
Video memory
4.
W/B memory
5.
Channel memory
6.
Installation memory
7.
Picture memory
8.
RCP memory
9.
Fan memory
10. UF memory
11. LUT memory
External NVM (EEPROM) : 256kbit
External NVM
Memory : Save the Data from
                CPU RAM to NVM
Initialize : FReset the Data to default value
Active memory copy : Load the Data from NVM to CPU RAM
CPU ROM
CPU RAM
No.01 
No.02
No.03
No.04
Status 
Memory
No.99
No.01 
No.02 
No.03 
No.04 
No.99 
No.101 
Input-A
User
No.120 
No.03 
No.04 
Component
Preset
No.99 
No.03 
No.04 
Status 
Memory
HDMI
Preset
No.99 
Status Memory
Set Memory
Set Memory
Set Memory 
Input-A
Preset
When the power is turned on to the projector, all data
inside the internal ROM are written into the NVM (Non-
volatile Memory).
When the power is turned to on to the projector, required
data for the current picture, such as status memory data,
etc., are selected from the respective memory blocks, and
are written into the internal RAM. When adjustment is
carried out, adjustment data are written into the NVM
automatically (items on the user mode) or by the trigger of
memory operation (items on the service mode), then stored
them. Be careful that the factory preset (adjusted) data of
the user adjustable items are all eliminated from the
memory when user performs adjustment of the adjustable
items (W/B and Device Adjust) and the memory operation
to memorize the user adjustment data into the NVM.
* When the power to the projector is turned off without memorizing the
adjustment data, the original factory preset (adjusted) data can be restored
by removing the power cord once and connect it back again.
1-23
VPL-VW60
High 
Middle 
Low
Custom1 
Custom2 
Custom3
Iris:Off
Custom3
High 
Middle 
Low
Custom1 
Custom2 
Custom3
High 
Middle 
Low
Custom1 
Custom2 
Custom3
High 
Middle 
Low
Custom1 
Custom2 
Custom3
Iris:Off
Custom3
Video Video 
S Video 
S Video 
Input-A Input-A 
Component Component 
HDMI 1
HDMI 1
HDMI 2
HDMI 2
 
W/B 
Memory  
High
Low
Custom1
Custom2
Custom3
Installation
Memory
Installation
Memory
Installation Memory
Channel 
Memory
Channel 
Memory
Channel Memory
Middle
High 
Middle 
Low
Custom1 
Custom2 
Custom3
Iris:On/Manua
High 
Middle 
Low
Custom1 
Custom2 
Custom3
Iris:Auto/Auto1/
Auto2
Iris:On/Manua
Iris:Auto/Auto1/
Auto2
Noinput 
NTSC3.58 
NTSC4.43 
PAL 
PALM 
PALN 
SECAM 
BW60 
BW50 
Video
Chroma
Memory
PAL60 
Noinput 
NTSC3.58 
NTSC4.43 
PAL 
PALM 
PALN 
SECAM 
BW60 
BW50 
Video
Chroma
Memory
[Video]
PAL60 
Noinput 
NTSC3.58 
NTSC4.43 
PAL 
PALM 
PALN 
SECAM 
BW60 
BW50 
Video
Chroma
Memory
[SVideo]
PAL60 
Video Chroma Memory
Up/Down inversion possible
Up/Down inversion impossible
Up/Down inversion possible
Up/Down inversion impossible
1-24
VPL-VW60
Dynamic 
Standard 
Cinema 
User1 
User2 
Video
User3 
Dynamic 
Standard 
Cinema 
User1 
User2 
S Video 
User3 
Dynamic 
Standard 
Cinema 
User1 
User2 
Input-A
User3 
Dynamic 
Standard 
Cinema 
User1 
User2 
Component 
User3 
Dynamic 
Standard 
Cinema 
User1 
User2 
HDMI 1
User3 
Dynamic 
Standard 
Cinema 
User1 
User2 
Picture
Memory
HDMI 2
User3 
Dynamic 
Standard 
Cinema 
User1 
User2 
Video
User3 
Dynamic 
Standard 
Cinema 
User1 
User2 
S Video 
User3 
Dynamic 
Standard 
Cinema 
User1 
User2 
Input-A
User3 
Dynamic 
Standard 
Cinema 
User1 
User2 
Component 
User3 
Dynamic 
Standard 
Cinema 
User1 
User2 
HDMI 1
User3 
Dynamic 
Standard 
Cinema 
User1 
User2 
Picture
Memory
HDMI 2
User3 
User1 User1 
User2 User2 
RCP 
Memory
User3
RCP 
Memory
User3
RCP Memory
Picture Memory
FAN Memory
FAN Memory
FAN Memory
IRIS Open
IRIS Close
UF
Memory
LUT Memory
IRIS Open
IRIS Close
UF
Memory
LUT Memory
IRIS Open
IRIS Close
UF
Memory
LUT Memory
1-8. Warning on Power Connection
Use a proper power cord for your local power supply.
The United
Continental
UK, Ireland, Australia,
Japan
China
States, Canada
Europe
New Zealand
Plug type
YP-3
YP-12A
*
YP-359
VM0722
Female end
YC-13
YC-13D
VM0303B
YC-13
VM0724
Cord type
SVT
H05VV-F
CEE (13) 53 rd (OC)
VCTF
227 IEC 53 (RVV)
Rated Voltage & Current
10A/125V
10A/250V
10A/250V
12A/125V
10A/250V
Safety approval
UL/CSA
VDE
VDE
DENANHO
CCC
* Use a rated plug that complies with the regulation of each country/region and the specifications.