DOWNLOAD Sony RM-PJVW60 / VPL-VW60 Service Manual ↓ Size: 11.3 MB | Pages: 124 in PDF or view online for FREE

Model
RM-PJVW60 VPL-VW60
Pages
124
Size
11.3 MB
Type
PDF
Document
Service Manual
Brand
Device
Projector / E1
File
rm-pjvw60-vpl-vw60.pdf
Date

Sony RM-PJVW60 / VPL-VW60 Service Manual ▷ View online

1-17
VPL-VW60
1-3-20. Extension Boards and Extension Cables
XC board 
x 3
XQ board
A-1 Z18   Flat connector assembly (50P) (R)
There are R, G, and B flat connector assemblies. 
A-2 Z19   Flat connector assembly (50P) (G)
A-3 Z20   Flat connector assembly (50P) (B)
B SH connector assembly (4P)
C SH connector assembly (5P)
D SH connector assembly (10P)
G 1.0 Flat connector assembly (24P)
F 0.5 Flat connector assembly (24P)
E SH connector assembly (11P) x 2
H  Flexible flat cable  (38P)
X kit assembly (Part No. 
A-1219-677-A
)
1-18
VPL-VW60
1-3-21. How to Extend Boards
1. C Board extension using XC extension boards.
2. C board extension connections
C board
Optics unit 
assembly
Front panel 
assembly
Hood assembly
C board
Q board 
CN300 (38P)
Optics unit assembly 
panel G (50P)
Optics unit assembly 
panel B (50P)
Optics unit assembly 
panel R (50P)
CN1002
CN1003
CN1000
CN6000
CN7000
CN5000
XC board
XC board
XC board
H
Flat connector assembly 
(50P) 
x 3
Note: 
Do not pull or stress the 50P flexible card 
wire coming from the panel on the optics 
unit assembly. 
Doing so may displace the panel and 
deteriorate image quality. 
C board holder
XC board
 
x 3
A-2
A-3
A-1
C board
Front Side
of Unit
 (G)
 (B)
 (R)
A-1 Z18   Flat connector assembly (50P) (R)
A-2 Z19   Flat connector assembly (50P) (G)
A-3 Z20   Flat connector assembly (50P) (B)
H  Flexible flat cable  (38P)
GB board CN601 (24P)
Q board CN603 (10P)
1-19
VPL-VW60
3. Q board extension using the XQ extension boards.
4. C Board extension connections
XQ board
XQ board
Q board
Exhaust duct
Hood assembly
Q board
B SH connector assembly  (4P)
C SH connector assembly  (5P)
D SH connector assembly  (10P)
E SH connector assembly  (11P) x 2
F 0.5 Flat connector assembly (24P)
G 1.0 Flat connector assembly (24P)
H Flexible flat cable  (38P)
C board 
CN1000 
(38P)
GB board 
CN700 
(24P)
GB board CN600 
(24P)
GS board CN200 
(4P)
C board CN1002 
(10P)
Lamp power 
supply
 X2 
(5P)
HA board CN60 
(4P)/
NR board CN50 
(3P)/
TL board CN75 
(2P)/
U board CN20 
(2P)
TA board CN70 
(3P)/
HB board CN80 
(5P)/
NF board CN40 
(3P)
CN73
CN1703
CN1702
CN1704
CN74
CN72
CN1603
CN63
H
F
G
XQ board
Front Side
of Unit
CN1600
CN60
CN703
CN702
CN704
CN603
CN300
CN601
CN400
Q board
CN600
E
D
B
E
C
1-20
VPL-VW60
1-4. Unleaded Solder
Boards requiring use of unleaded solder are printed with a
lead free mark (LF) indicating the solder contains no lead.
(Caution: Some printed circuit boards may not come
printed with the lead free mark due to their particular size.)
 : LEAD FREE MARK
m
. Be sure to use the unleaded solder for the printed circuit
board printed with the lead free mark.
. The unleaded solder melts at a temperature about 40 dC
higher than the ordinary solder, therefore, it is recom-
mended to use the soldering iron having a temperature
regulator.
. The ordinary soldering iron can be used but the iron tip
has to be applied to the solder joint for a slightly longer
time. The printed pattern (copper foil) may peel away if
the heated tip is applied for too long, so be careful.
1-5. Service Know-How
1-5-1. When the Optical Unit ASSY is
Replaced
1.
Write the Look Up Table/3D gamma data contained in
the attached floppy disk.
See “1-6. Writing Look Up Table/3D gamma/DDC
data” for more about how to write data.
2.
Perform white balance adjustment. (See “2-3. Servic-
ing White Balance Adjustment”)
3.
Change the IRIS data to the values of the IRIS adjust-
ment data stored in the supplied floppy disk. For how
to change the data, refer to “1-5-3. IRIS Copy”.
1-5-2. When the Board is Replaced
1.
When the Q board is replaced
a)
Change the IRIS data to the values of the IRIS
adjustment data before replacement. (For the
method to change the IRIS data, refer to “1-5-3.
IRIS Copy”.)
b) Change the W/B data to the values of the W/B
adjustment data before replacement. (For the
method to change the W/B data, refer to “1-5-4.
W/B Copy”.)
When the adjustment data cannot be copied, adjust
W/B. (Refer to “2-3. Servicing White Balance
Adjustment”.)
2.
When the F, GA, GB, GS, HA, HB, NF, NR, TA, TL,
or U board is replaced
No particular adjustments are needed.
3.
When the C board is replaced
Remove IC2000 from the old C board and install them
to the new C board that is supplied as the repair part,
before replacement.
1-5-3. IRIS Copy
1.
Enter the Service Mode. (Refer to “2-1-2. How to
Enter the Service Mode”.)
2.
Set OTHER: 01 Iris Adj in the Device Menu to 1.
3.
Change the value of OTHER: 02 Iris/Open_Reg.
4.
Change the value of OTHER: 03 Iris/Close_Reg.
5.
Return OTHER: 01 Iris Adj in the Device Menu to 0.
6.
Perform Save to Memory.
1-5-4. W/B Copy
1.
Input the 1080/60i flat-field (three RGB colors) to the
HDMI1 terminal.
2.
Enter the Service Mode. (Refer to “2-1-2. How to
Enter the Service Mode”.)
3.
Enter the W/B mode in the Device Menu.
4.
Change the values of Gain R/G/B and Bias R/G/B in
each mode (High/Middle/Low/User1/User2/User3).
5.
Perform Save to Memory.
* W/B data has a memory for each of the three IRIS modes (AUTO1/2,
Manual, and OFF). Perform the above steps for each IRIS mode.
Page of 124