DOWNLOAD Sony RM-PJVW200 / VPL-VW200 Service Manual ↓ Size: 19.55 MB | Pages: 127 in PDF or view online for FREE

Model
RM-PJVW200 VPL-VW200
Pages
127
Size
19.55 MB
Type
PDF
Document
Service Manual
Brand
Device
Projector / E1
File
rm-pjvw200-vpl-vw200.pdf
Date

Sony RM-PJVW200 / VPL-VW200 Service Manual ▷ View online

1-9
VPL-VW200
1-3-8. TL Board
1-3-9. UA Board and UB Board
4 Two screws
      (+BVTP 3 
x 12)
1 Screw
      (+BVTP 3 
x 12)
5 UB board
UA board
CN20
CN26
CN25
2 UA holder
4 Two screws
     (+PSW M3 
x 8)
6 Screw
     (+PSW M3 
x 8)
5 Fan cover (120MDL),
      Thermo bracket, etc.
3 TL board
      CN71
9 TL board
2
 
Remove the harness 
     from the three claws. 
1 Open the reuse clamp.
8 Fan cover
     (120MDL)
7 Thermo bracket
0 Fuse connector 
     assembly
1-10
VPL-VW200
1-3-10. HA Block Assembly
1 Two screws
      (+BVTP 3 
x 12)
2 Push the shield cover (H) in the 
     direction of A, and slide it to 
     remove the HA block assembly. 
!- HA block assembly
4 Two claws
7 Screw
     (+BVTP 3 
x 12)
3 Screw
      (+BVTP 3 
x 12)
9 HA board
8 Button (+)
5 Remove the shield plate (H)
     in the direction of the arrow B.
0 Remove the shield cover (H)
     in the direction of the arrow C.
CN60
CN60
6 Shield plate (H)
HA board
B
C
A
1-11
VPL-VW200
1-3-11. Hood Assembly and NR Board
1 Three screws
      (+BVTP 3 
x 12)
2 Rear duct (F),
     Lamp stopper
3 Lamp stopper
     spring     
!= Claw
![ Lamp stopper
 Rear duct (F)
4 Three screws
      (+BVTP 3 
x 12)
5 Rear duct (I)
 Lamp stopper spring     
 Lamp stopper
9 Screw
      (+PSW M3 
x 8)
!- Hood assembly
6
 Screw
      (+BVTP 3 
x 12)
0 NR board
8 Remove the mesh (R) in the 
     direction of the arrow.
7 Two claws
CN50
1-12
VPL-VW200
1-3-12. Optics Unit Section
2  Three screws
     (+PSW M4 
x 16)
4 Two screws
     (+BVTP 3 
x 12)
5 V
 board
Remove the optics unit 
     section in the direction 
     of the arrow.
CN30
Fan connector
GB board
CN701
Four lead wire with connectors (LVDS)
CA board
CB board
GB board
CN101
CN701
CN800
Fan 
connector
Flat connector assembly A
 (30P)
CN100
1 Remove all connectors respectively.
Front Side
of Unit
CN100
CN101
CN102
CN103
Be careful not to break each flat connector assembly. 
GB Board
Four lead wire with 
connectors (LVDS)
Flat connector assembly
 A
 (30P)
Sheet LVDS 
Front Side
of Unit
Route the CN101 harness 
outside CN100.
Fix CN100 and 
CN101 together 
with an acetate tape. 
Do not route the 
harness through 
this hook. 
To CN100 on 
the CB board.
To CN101 on 
the CB board.
Page of 127
Display