Information Menu
The Information menu is used to display the information and status of the unit.
• Displaying Serial Number
Selecting Serial Number of the Information menu display the serial number of the unit.
• Displaying the temperature of the image sensor
The internal temperature of around the CMOS imager can be monitored by Imager Temp. of the Information
menu.
• Displaying Internal Temperature
The internal temperature around the DPR-365 board can be monitored by Main Board Temp of the Information
menu.
• Outputting Log Dump
Outputting log to a UTILITY card by press EXECUTE.
Version 1 Menu
• Package: Firmware version
• IC2300 (AVP-25 board) version
• IC2400 (DPR-365 board) version
• IC2400 (DPR-365 board) version
• IC0100 (DPR-365 board) version
• IC1900 (DPR-365 board) version
Version 2 Menu
• IC1100 (DPR-365 board) version
• IC0201 (VIF-58 board) version
Version 3 Menu
• IC3102 (AVP-25 board) version
• IC2803 (DPR-365 board) version
• IC631 (KY-739 board) version
PXW-FS7/PXW-FS7K
2-5
2-5. 
Precaution on Replacing the IM E Mount Base Block Assy
Perform the following procedures for each of the three washers.
Note
Measure the dimensions before replacement of the IM E Mount Base Block Assy according to procedures 1 to 3.
1.
Remove the Imager Block Assy and the IM Adjust Washers (A).
IM Module Sub Block Assy
IM Adjust Washers (A)
PXW-FS7/PXW-FS7K
2-6
2.
Measure the dimensions [A] of the removed IM Adjust Washers.
[A] + [B]
[A]
[B]
SSM height adjustment
measurement JIG
J-6082-689-A
3.
Measure the distance [B] between the surface of the screw hole where the IM Adjust Washers were set and the
surface of the E-Mount.
4.
Likewise, measure the dimensions [B’] of each location where IM Adjust Washers of the IM Module Sub Block
Assy are installed, after replace the IM E Mount Base Block Assy.
5.
Calculate the dimension [A’] of new IM Adjust Washer by using the formula below, and select the washers.
Dimension [A’] of new IM Adjust Washer = ([A] + [B]) – [B’]
[A] + [B] : Dimension of before replacement
[B’] : Dimension of new IM Module Sub Block Assy
6.
Assemble the imager, using the selected IM Adjust Washers.
7.
After assembling is completed, perform the test shooting and confirm that no blur is observed in the peripheral
area of shot.
PXW-FS7/PXW-FS7K
2-7