Section 1
Trouble Shooting
1-1. 
Self-diagnosis Function
1-1-1. 
Self-diagnosis Function
If an error occurs in this unit, the self-diagnosis function starts working and a code consisting of one alphabet and a four-
digit number appears on the LCD. Classification of persons in charge, classification of faulty blocks, and details of errors
can be checked by referring to this indication of five alphanumeric characters in the self-diagnosis code table.
The history of past errors can be checked in “Usage and Diag record” on the DATA tab of the Adjust Manual.
The self-diagnosis function is also described in the operation manual.
1-1-2. 
Self-diagnosis Code Table
Self-diagnosis
Code
Symptom/State
Correction
A0-000
System error by software
Ask the headquarters about correction of this error.
E10-005
Lens overheating
Exchange the lens.
E10-006
Lens overheating
Exchange the lens.
E10-007 
*1
Handshake correction function does
not work well
Turn the power off and on again.
E10-008 
*1
Handshake correction function does
not work well
Turn the power off and on again.
E10-009 
*1
Image vibration correction during
handshake function does not work
Turn the power off and on again.
E10-00B
Temperature abnormality of the lens
Exchange the lens.
E10-101
Abnormalities in zoom initialization
of the lens
Exchange the lens.
E10-102
Abnormalities in focus initialization
of the lens and abnormalities in zoom
initialization of the lens occurred si-
multaneously
Exchange the lens.
E10-103
Abnormalities in initialization of the
lens
Exchange the lens.
E10-104
Abnormalities in initialization of the
lens
Exchange the lens.
E10-10A
Focus operation failure of the lens
Exchange the lens.
E12-001 
*1
Abnormality of the variable ND fil-
ter
Turn the power off and on again.
E12-002 
*1
Abnormality of the variable ND fil-
ter
Turn the power off and on again.
E40-001
Battery current value goes over the
max discharge current
Check the remaining battery power because this symptom maybe de-
pended on the remaining battery level, and confirm whether or not
the symptom is occurred after replacing the battery.
If the symptom is still occurred, IC2300 and IC3102 on the AVP-25
board, or the peripheral circuit may be faulty.
Replace the AVP-25 board.
E40-002
Battery pack temperature goes over
the specified value.
Change the battery pack or place it in a cool place.
When this error is not cleared, replace the RE-328 board and/or the
AVP-25 board.
E40-003
Error of battery authentication
Use the Sony genuine battery.
When this error is not cleared, replace the RE-328 board and/or the
AVP-25 board.
Continued
*1:
Function of this code is not provided in this unit.
PXW-FS7/PXW-FS7K
1-1
Self-diagnosis
Code
Symptom/State
Correction
E91-118
Memory error of IC2300 on the
AVP-25 board
IC2300 and IC2701 on the AVP-25 board or the peripheral circuit
may be faulty.
Replace the AVP-25 board.
E91-11D
Communication error between
IC2300 and IC2700 on the AVP-25
board
IC2300 and IC2700 on the AVP-25 board or the peripheral circuit
may be faulty.
Replace the AVP-25 board.
E91-133
Communication error between
IC0100 on the DPR-365 board and
IC2300 on the AVP-25 board
IC0100 on the DPR-365 board and IC2300 on the AVP-25 board or
the peripheral circuit may be faulty.
Replace the faulty DPR-365 board and/or the AVP-25 board.
E91-145
Communication error between
IC2300 and IC3102 on the AVP-25
board
IC2300 and IC3102 on the AVP-25 board, or the peripheral circuit
may be faulty.
Replace the AVP-25 board.
E91-1C0
Network control error
IC2300 on the AVP-25 board and IF-1273 board or the peripheral
circuit may be faulty.
Replace the faulty AVP-25 board and/or the IF-1273 board.
E91-1D0
Can not get the GPS data
Check that the GP-1019 board is not abnormality.
And check the connection between AVP-25 board, CN-3742 board,
CN-3743 board, HN-421 board and GP-1019 board.
When this error is not cleared, replace the faulty AVP-25 board,
CN-3742 board, CN-3743 board, HN-421 board and/or GP-1019
board.
E91-210
Communication error between
IC1700 on the DPR-365 board and
IC2300 on the AVP-25 board
IC1700 on the DPR-365 board, IC2300 on the AVP-25 board, or the
peripheral circuit may be faulty.
Replace the faulty DPR-365 board and/or the AVP-25 board.
E91-228
Memory error of IC1700 on the
DPR-365 board
IC1700 and IC1903/IC1904 on the DPR-365 board or the peripheral
circuit may be faulty.
Replace the DPR-365 board .
E91-230
Communication error between
IC1700 and IC0100 on the DPR-365
board
IC1700 and IC0100 on the DPR-365 board, or the peripheral circuit
may be faulty.
Replace the DPR-365 board .
E91-250
Communication error between
IC1700 and IC1200 on the DPR-365
board
IC1700 and IC1200 on the DPR-365 board, or the peripheral circuit
may be faulty.
Replace the DPR-365 board .
E91-265
Communication error with extension
unit
IC1700 on the DPR-365 board and CN3005 on the IF-1270 board, or
the peripheral circuit may be faulty.
Check the connection between DPR-365 board and IF-1270 board.
And check the connection of the extension connector (CN3005 on the
IF-1270 board).
Replace the faulty DPR-365 board and/or the IF-1270 board.
E91-270
USB connection error
IC1700 on the DPR-365 board, or the peripheral circuit may be faulty.
Replace the DPR-365 board .
E91-275
PCI communication error
IC1700 on the DPR-365 board and CN3005 on the IF-1270 board, or
the peripheral circuit may be faulty.
Check the connection between DPR-365 board and IF-1270 board.
And check the connection of the extension connector (CN3005 on the
IF-1270 board).
Replace the faulty DPR-365 board and/or the IF-1270 board.
E91-280
Communication error between
IC1700 on the DPR-365 board and
IC2300 on the AVP-25 board
IC1700 on the DPR-365 board, IC2300 on the AVP-25 board, or the
peripheral circuit may be faulty.
Replace the faulty DPR-365 board and/or the AVP-25 board.
E91-338
Memory error of IC0100 on the
DPR-365 board
IC0100 and IC0702 on the DPR-365 board or the peripheral circuit
may be faulty.
Replace the DPR-365 board .
E91-339
Memory error of IC0100 on the
DPR-365 board
IC0100 and IC0702 on the DPR-365 board or the peripheral circuit
may be faulty.
Replace the DPR-365 board .
E91-350
Communication error between
IC0100 on the DPR-365 board and
IC0201 on the VIF-58 board
IC0100 on the DPR-365 board and IC0201 on the VIF-58 board or
the peripheral circuit may be faulty.
Replace the faulty DPR-365 board and/or the VIF-58 board.
Continued
PXW-FS7/PXW-FS7K
1-2
Self-diagnosis
Code
Symptom/State
Correction
E91-357
Memory error of IC0201 on the
VIF-58 board
IC0201 and IC0300 on the VIF-58 board or the peripheral circuit may
be faulty.
Replace the VIF-58 board.
E91-360
Communication error between
IC0100 on the DPR-365 board and
extension unit
IC0100 on the DPR-365 board and CN3005 on the IF-1270 board, or
the peripheral circuit may be faulty.
Check the connection between DPR-365 board and IF-1270 board.
And check the connection of the extension connector (CN3005 on the
IF-1270 board).
Replace the faulty DPR-365 board and/or the IF-1270 board.
E91-367
Memory error of IC0201 on the
VIF-58 board
IC0201 and IC0300 on the VIF-58 board or the peripheral circuit may
be faulty.
Replace the VIF-58 board.
E91-377
Operation fault of IC0800 on the
VIF-58 board
IC0100 on the DPR-365 board and IC0800 on the VIF-58 board or
the peripheral circuit may be faulty.
Replace the faulty DPR-365 board and/or the VIF-58 board.
E91-380
Communication error of IC0100 on
the DPR-365 board
IC0100 on the DPR-365 board or the peripheral circuit may be faulty.
Replace the DPR-365 board.
E91-390
Communication error between
IC0100 on the DPR-365 board and
IC0400 on the VIF-58 board
IC0100 on the DPR-365 board and IC0400 on the VIF-58 board or
the peripheral circuit may be faulty.
Replace the faulty DPR-365 board and/or the VIF-58 board.
E91-610 
*1
Abnormality of steadyshot circuit
Turn the power off and on again.
E91-61E 
*1
Abnormality of IC for steadyshot
Turn the power off and on again.
E91-623 
*1
Abnormality of steadyshot circuit
Turn the power off and on again.
E91-627 
*1
Abnormality of IC for steadyshot
Turn the power off and on again.
E92-204
Communication error between
IC0100 and IC1700 on the DPR-365
board
IC0100 and IC1700 on the DPR-365 board, or the peripheral circuit
may be faulty.
Replace the DPR-365 board.
E92-205
Communication error between
IC0100 and IC1700 on the DPR-365
board
IC0100 and IC1700 on the DPR-365 board, or the peripheral circuit
may be faulty.
Replace the DPR-365 board.
E92-206
Communication error between
IC0100 and IC1700 on the DPR-365
board
IC0100 and IC1700 on the DPR-365 board, or the peripheral circuit
may be faulty.
Replace the DPR-365 board.
E92-303
Communication error between
IC0100 and IC2901 on the DPR-365
board
IC0100 and IC2901 on the DPR-365 board or the peripheral circuit
may be faulty.
Replace the DPR-365 board.
E95-124 
*1
Abnormal termination of Wi-Fi
module firmware upgrade
Turn the power off and on again.
E95-201
Operation fault of IC1700 on the
DPR-365
IC1700 on the DPR-365 board or the peripheral circuit may be faulty.
Replace the DPR-365 board.
E95-202
Operation fault of IC1700 on the
DPR-365
IC1700 on the DPR-365 board or the peripheral circuit may be faulty.
Replace the DPR-365 board.
E95-203
Operation fault of IC1700 on the
DPR-365
IC1700 on the DPR-365 board or the peripheral circuit may be faulty.
Replace the DPR-365 board.
E95-204
Operation fault of IC1700 on the
DPR-365
IC1700 on the DPR-365 board or the peripheral circuit may be faulty.
Replace the DPR-365 board.
E95-205
Operation fault of IC1200 on the
DPR-365
IC1200 on the DPR-365 board or the peripheral circuit may be faulty.
Replace the DPR-365 board.
E95-206
Operation fault of IC1200 on the
DPR-365
IC1200 on the DPR-365 board or the peripheral circuit may be faulty.
Replace the DPR-365 board.
E95-207
Operation fault of IC1200 on the
DPR-365
IC1200 on the DPR-365 board or the peripheral circuit may be faulty.
Replace the DPR-365 board.
E95-311
Operation fault of IC0100 on the
DPR-365
IC0100 on the DPR-365 board or the peripheral circuit may be faulty.
Replace the DPR-365 board.
Continued
*1:
Function of this code is not provided in this unit.
PXW-FS7/PXW-FS7K
1-3
Self-diagnosis
Code
Symptom/State
Correction
E95-312
Communication error between
IC9001 on the IS-102 board and
IC0100 on the DPR-365 board
IC9001 on the IS-102 board and IC0100 on the DPR-365 board or
the peripheral circuit may be faulty.
Replace the faulty IS-102 board and/or the DPR-365 board.
E95-313
Communication error between
IC0100 on the DPR-365 board and
extension unit
IC0100 on the DPR-365 board and CN3005 on the IF-1270 board, or
the peripheral circuit may be faulty.
Check the connection between DPR-365 board and IF-1270 board.
And check the connection of the extension connector (CN3005 on the
IF-1270 board).
Replace the faulty DPR-365 board and/or the IF-1270 board.
E95-314
Communication error between
IC0100 and IC1200 on the DPR-365
board
IC0100 and IC1200 on the DPR-365 board or the peripheral circuit
may be faulty.
Replace the DPR-365 board.
E95-315
Communication error between
IC0100 on the DPR-365 and IC0201
on the VIF-58 board
IC0100 on the DPR-365 and IC0201 on the VIF-58 board or the pe-
ripheral circuit may be faulty.
Replace the faulty DPR-365 board and/or the VIF-58 board.
E95-316 
*1
Communication error between
IC0100 on the DPR-365 board and
IC0201 on the VIF-58 board
Turn the power off and on again.
E95-317
Communication error between
IC0100 on the DPR-365 board and
external viewfinder
IC0100 on the DPR-365 board and CN301 on the VF-93 board or the
peripheral circuit may be faulty.
Replace the faulty DPR-365 board and/or the VF-93 board.
E95-318
Operation fault of IC0800 on the
VIF-58 board
IC0100 on the DPR-365 board and IC0800 on the VIF-58 board or
the peripheral circuit may be faulty.
Replace the faulty DPR-365 board and/or the VIF-58 board.
*1:
Function of this code is not provided in this unit.
PXW-FS7/PXW-FS7K
1-4
Page of 127