1-2
HDR-PJ260/PJ260E/PJ260V/PJ260VE/XR260E/XR260V/XR260VE_L2
1-3.  ADDITION OF DESTINATION DATA FILE
If the Destination Data file included in the Adjust manual is old, “DESTINATION DATA WRITE” cannot be executed in some cases.
In that case, download a new Destination Data file from the TISS homepage according to the following procedure.
Note 1:  To perform Destination Data Write for this model, the Adjust manual of the DSC-WX50 series must have been installed.
 
Install the Adjust manual of the DSC-WX50 series in advance.
Note 2:  The actual image may differ from the image shown above.
1)  If the Destination Data file in the Adjust manual in use is old, the window shown in Fig. 1 is displayed.
 
Click the [OK] button.
 Fig. 
1
2)  The Destination Data Write window opens.
 
Check the version of the Destination Data file retained in the Adjust manual.
Destination Ver. window
3)  Search the model whose new Destination Data file you want to get on the TISS homepage.
 
When the Destination Data file has been updated, a file with a name “Destination File For ‘model name’.zip” is registered.
(Example) Destination File For DSC-WX50.zip
Furthermore, the version supported by the Destination Data file is shown in the Remarks column.
Note : If the Destination Data file has not been updated, contact the Service Headquarters.
 4)  Download the Destination Data file of the relevant model and unzip the file.
5)  Execute “DESTINATION DATA WRITE” in the Adjust tab of the Adjust manual.
 
Click the [START] button.
Ver. 1.1 2012.01
1-3
HDR-PJ260/PJ260E/PJ260V/PJ260VE/XR260E/XR260V/XR260VE_L2
6)  Click the [File Update] button in the window.
 
7)  A file selection screen opens. Select the Destination Data file to be added and click the [Open] button.
 
8)  When the file has been successfully added, the following window opens.
 
9)  Check the Destination Ver. window and confirm that the version has been updated.
Destination Ver. window
The changed portions from
Ver. 1.0 are shown in blue.
Ver. 1.1 2012.01
1-4.
  PRECAUTION ON REPLACING THE MS-478 BOARD
Angular Velocity Sensor
When you replace to the repairing board, write down the sensitivity displayed on the angular velocity sensor SE7501 (PITCH/YAW).
Start the Adjust Manual in the Adjust Station and execute the “GYRO sensor sensitivity adj”.
Note: The sensor sensitivity of SE7501 (PITCH/YAW) on MS-478 board is written only repair parts.
G1
G2
PP: PITCH sensor sensitivity
YY: YAW sensor sensitivity
YY
PP
MS-478 BOARD (SIDE B)
SE7501
1-4
HDR-PJ260/PJ260E/PJ260V/PJ260VE/XR260E/XR260V/XR260VE_L2
1-6.
 SELF-DIAGNOSIS FUNCTION
1-6
-1. Self-diagnosis Function
When problems occur while the unit is operating, the self-diagnosis 
function starts working, and displays on the LCD screen what to do.
This function consists of two display; self-diagnosis display and service 
mode display.Details of the self-diagnosis functions are provided in the 
Instruction manual.
1-6
-2. Self-diagnosis Display
When problems occur while the unit is operating, the counter of the LCD 
screen shows a 4-digit display consisting of an alphabet and numbers,
which blinks at 3.2 Hz. This 5-character display indicates the “repaired 
by:”, “block” in which the problem occurred, and “detailed code”of the 
problem.
0 0
3 2
C
Repaired by:
Refer to “1-6-3. Self-diagnosis Code Tabl e”.
Indicates the appropriate
step to be taken.
E.g.
13 ....
32 ....Turn on power again.
Block
Detailed Code
Blinks at 3.2 Hz
C : Corrected by customer
E : Corrected by service
engineer
Format the “memory card”.
LCD screen
1-5.
  PRECAUTION ON REPLACING THE LENS
When replacing the lens, write down the PITCH/YAW data given on the data sheet of the replacement lens for service.
Start the Adjust Manual in the Adjust Station and execute the “GYRO sensor sensitivity Adj”.
PITCH data
YAW data
P.PP/Y.YY
L2
L1
P.PP/Y.YY
The changed portions from
Ver. 1.0 are shown in blue.
Ver. 1.1 2012.01
1-6
-3. Self-diagnosis Code Table
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
C
0
4
0
0
Non-standard battery is used.
Use the InfoLITHIUM battery.
C
0
6
0
0
The battery pack temperature is high.
Change the battery pack or place it in a cool place.
C
1
3
0
Memory card is unformatted.
Memory card is broken.
Format the memory card.
Insert a new memory card.
C
1
3
0
2
Access error
Remove the power source. Reconnect it again and operate your cam-
corder again.
C
1
3
0
3
Access error (External media)
Turn power off and turn power on again.
C
1
3
0
4
Drive fault (External media)
Turn power off and turn power on again.
C
E
3
2
6
1
6
0
0
0
Difficult to adjust focus
(Cannot initialize focus)
Retry turn the power on by the power switch. If it does not recover, check 
the focus sensor of lens block (pin 7 of CN4002 on the LD-279 board). 
If it is OK, check the focus motor drive IC (IC5501 on the VC-653 board).
E
2
0
0
0
Flash memory data are rewritten.
Make flash memory data correct value. (Note 1)
E
3
1
0
0
Drive fault
Turn power off and turn power on again.
E
6
1
1
0
Zoom operations fault
(Cannot initialize zoom lens.)
Inspect the lens block zoom sensor signal (pin 9 of CN4002 on the LD-
279 board) when zooming is performed when the zoom lever is operated, 
and the zoom motor drive circuit (IC5501 on the VC-653 board) when 
zooming is not performed.
E
6
1
1
1
The abnormalities in initialization of 
the focus lens and the abnormalities in 
initialization of the zoom lens occurred 
simultaneously.
Check both C: 32: 60 and E: 61: 10 of the self-diagnosis code.
E
6
1
3
0
Reset position detection error on the step-
per iris initializing
Turn the power on to open lens barrier. Disconnect the battery or power 
cord, and then connect again.
Confirm that the iris blades in lens are working.
If iris blades do not working, check the iris motor drive IC in lens drive 
block (CN4002 pin qj, qk on LD-279 board).
If iris blades work normally, confirm that they are closing completely 
and confirm following item.
・  Case of the iris blades do not close normally Replace the lens block).
・  Case of “E: 61: 30” is appeared and iris blades closed completely.
  Confirm that communication with lens block is normal.
・  Case of LCD is not displayed normally Check that connection between 
CN6702 on CM-123 board and CN4002 on VC-653 board by FP-1488 
flexible board.
・  Case of LCD is displayed normally Replace the lens block.
E
6
2
0
0
Handshake correction function does not 
work well. (With PITCH angular velocity 
sensor output stopped.)
Inspect PITCH angular velocity sensors (SE7501 on the MS-478 board) 
peripheral circuits.
E
6
2
0
1
Handshake correction function does not 
work well. (With YAW angular velocity 
sensor output stopped.)
Inspect YAW angular velocity sensors (SE7501 on the MS-478 board) 
peripheral circuits.
E
6
2
0
2
Abnormality of IC for steadyshot.
Refer to [
1-7
-1. E : 62 : 02 (Abnormality of IC for Steadyshot) Occurred].
E
6
2
0
3
IC for steadyshot and micro controller 
communication abnormality among.
Inspect the steadyshot circuit (IC5501 on the VC-653 board).
E
6
2
0
4
Image vibration correction during
handshake function does not work.
Inspect the image vibration angular velocity sensors (SE7701 on the 
LD-279 board) peripheral circuits.
E
6
2
1
0
Shift lens initializing failure.
Replacement of lens block. (Note 3) If an error occurs again, replace 
the VC-653 board.
E
6
2
1
1
Shift lens overheating (Pitch)
Refer to [
1-7
-2. E : 62 : 11 (Shift Lens Overheating (Pitch)) Occurred].
E
6
2
1
2
Shift lens overheating (Yaw)
Refer to [
1-7
-3. E : 62 : 12 (Shift Lens Overheating (Yaw)) Occurred].
Note 1: Start the Adjust Manual in the Adjust Station and refer to the “DESTINATION DATA WRITE”.
Note 2: Functions of codes with * mark are not provided in this unit.
*
*
*
(                                           )
1-5
HDR-PJ260/PJ260E/PJ260V/PJ260VE/XR260E/XR260V/XR260VE_L2
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
E
6
2
2
0
Abnormality of thermistor.
Refer to [
1-7
-4. E : 62 : 20 (Abnormality of Thermistor) Occurred].
E
9
1
0
1
Abnormality when flash is being charged.
Turn power off and turn power on again.
E
9
1
0
2
Abnormality of LED Video light.
Turn power off and turn power on again.
E
9
1
0
3
Abnormality of LED Video light  Tempera-
ture detection.
Turn power off and turn power on again.
E
9
2
0
1
Battery current value goes over the max 
discharge current
Check the remaining battery power because this symptom maybe 
depended on the remaining battery level, and confirm whether or 
not the symptom is occurred after replacing the battery. If the symp-
tom is still occurred, overhaul inspection is needed. Check each 
output of DC/DC converter (IC4301 on the VC-653 board) with 
connected the DC JACK (J901) on the VC-653 board. 
(The minimum connection to periphery)
E
9
4
0
0
Fault of writing or erasing the flash mem-
ory
IM Model:
Inspect the flash memory (IC8101 on the LD-279 board).
E
9
4
0
1
Internal flash memory fault
IM Model:
Inspect the flash memory (IC8101 on the LD-279 board).
E
9
4
0
2
BGM data error
Check the CPU (IC1301 on the VC-652 board).
E
9
5
0
0
GPS hardware error
GPS Model:
Check whether the FFC-254 flexible flat cable is broken,and check 
whether it is inserted imperfectly.
If there is no problem the flexible board, inspect or replacement of 
the GP-037 board.
E
9
6
0
0
Map area mount error
HDD Model:
Inspect or replacement of the HDD.
IM Model: 
Inspect or replacement of the LD-279 board.
E
9
7
0
0
Projector  hardware error
Turn power off and turn power on again.
Note 3: When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
*
*
*
1-7.
  METHOD OF COPING WITH SHIFT LENS ERROR
LD-279 BOARD (SIDE A)
IC5501
R5505
C5526
C5529
C5528
C5527
Fig. 1
Measurement points on the VC-652 board
about 330 msec
Note: The length of low section will vary a little depending on the conditions.
Fig. 2
Change in output voltage of R5505 on the LD-279 board
1-7
-1. E : 62 : 02 [Abnormality of IC for Steadyshot] Occurred
Order
Procedure
1
Turn the power OFF.
2
While measuring with an oscilloscope the output voltage of R5505 in the periphery of IC5501 on the LD-279 board, turn the power ON 
to check that the output voltage immediately after the power on change as shown in Fig. 2.
3
If the output voltage change as shown in Fig. 2, replace the lens block (Note). If it does not change as shown in Fig. 2, inspect the camera 
control circuit (IC1301 of VC-653 board) periphery.
Note:  When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
The changed portions from
Ver. 1.0 are shown in blue.
Ver. 1.1 2012.01