Sony HDR-HC9 / HDR-HC9E (serv.man2) Service Manual ▷ View online

1-2
ENGLISH
JAPANESE
ENGLISH
JAPANESE
HDR-HC9/HC9E_L2
1-5. SELF-DIAGNOSIS  FUNCTION
1-5-1. Self-diagnosis Function
When problems occur while the unit is operating, the self-diagnosis
function starts working, and displays on the viewfinder or LCD
screen what to do.
Details of the self-diagnosis functions are provided in the Instruction
manual.
1-5-2. Self-diagnosis Display
When problems occur while the unit is operating, the counter of the
viewfinder or LCD screen shows a 4-digit display consisting of an
alphabet and numbers, which blinks at 3.2 Hz. This 5-character
display indicates the “repaired by:”, “block” in which the problem
occurred, and “detailed code” of the problem.
1 1
3 1
C
Repaired by:
Refer to  1-5-3. Self-diagnosis Code Table .
Indicates the appropriate
step to be taken.
E.g.
31 ....Reload the tape.
32 ....Turn on power again.
Block
Detailed Code
Blinks at 3.2Hz
C : Corrected by customer
H : Corrected by dealer
E : Corrected by service
engineer
Viewfinder or LCD screen
C : 3 1 : 1 1
1-4. USING SERVICE JIG
Connect the CPC-15 jig connector (J-6082-564-A) and I/F unit for LANC control (J-6082-521 A) to the CN8103 on the US-013 board.
1
1
8
2
7
8
1
8
CN8003
CN8101
CN8001
(SIDE B)
CN1012
26
26
1
1
1
8
VC-500 BOARD
(SIDE A)
CPC-15
(J-6082-564-A)
I/F unit for LANC control
(J-6082-521-A)
CN8103
MS-361 BOARD
(SIDE A)
US-013 BOARD
(SIDE A)
1-3
ENGLISH
JAPANESE
ENGLISH
JAPANESE
HDR-HC9/HC9E_L2
1-5-3. Self-diagnosis Code Table
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
Block
Function
0
4
2
1
2
2
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
Detailed
Code
0
0
0
0
0
0
1
0
1
1
2
0
2
1
2
2
2
3
3
0
3
1
4
0
4
1
4
2
4
3
4
4
1
0
1
1
2
0
2
1
2
2
2
3
3
0
3
1
4
0
4
1
4
2
4
3
4
4
6
0
Symptom/State
Non-standard battery is used.
Condensation.
Video head is dirty.
LOAD direction. Loading does not
complete within specified time
UNLOAD direction. Loading does not
complete within specified time
T reel side tape slacking when unloading.
S reel side tape slacking when unloading.
T reel fault.
S reel fault.
FG fault when starting capstan.
FG fault during normal capstan operations.
FG fault when starting drum.
PG fault when starting drum.
FG fault during normal drum operations.
PG fault during normal drum operations.
Phase fault during normal drum operations.
LOAD direction loading motor time-
out.
UNLOAD direction loading motor
time-out.
T reel side tape slacking when
unloading.
S reel side tape slacking when
unloading.
T reel fault.
S reel fault.
FG fault when starting capstan.
FG fault during normal capstan
operations.
FG fault when starting drum.
PG fault when starting drum.
FG fault during normal drum
operations.
PG fault during normal drum
operations.
Phase fault during normal drum
operations.
Difficult to adjust focus.
(Cannot initialize focus.)
Self-diagnosis Code
Repaired by:
Correction
Use the InfoLITHIUM battery.
Remove the cassette, and insert it again after one hour.
Clean with the optional cleaning cassette.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
If it does not recover, inspect the focus MR sensor of lens block
(Pin qh, qk of CN5301 on the LD-221 board).
If not faulty, inspect the focus motor drive circuit
(IC5404 on the LD-221 board).
1-4
ENGLISH
JAPANESE
ENGLISH
JAPANESE
HDR-HC9/HC9E_L2
E
E
E
E
E
E
E
E
E
E
E
Block
Function
6
1
6
1
6
2
6
2
6
2
6
2
6
2
6
2
6
2
6
2
9
1
Detailed
Code
1
0
1
1
0
0
0
1
0
2
0
3
1
0
1
1
1
2
2
0
0
1
Symptom/State
Zoom operations fault.
(Cannot initialize zoom lens.)
Focus lens initializing failure and zoom
lens initializing failure occur simulta-
neously.
Steadyshot function does not work well.
(With pitch angular velocity sensor output
stopped.)
Steadyshot function does not work well.
(With yaw angular velocity sensor output
stopped.)
Abnormality of IC for steadyshot.
IC for steadyshot and micro controller
communication abnormality among.
Shift lens initializing failure.
Shift lens overheating (Pitch).
Shift lens overheating (Yaw).
Abnormality of thermistor.
Abnormality when flash is being charged.
Self-diagnosis Code
Repaired by:
Correction
Inspect the zoom MR sensor of lens block (Pin w;, wa of CN5301
on the LD-221 board) when zooming is performed when the zoom
switch is operated and the zoom motor drive circuit (IC5404 on
the LD-221 board) when zooming is not performed.
Check both C: 32: 60 and E: 61: 10 of the self-diagnosis code.
Inspect pitch angular velocity sensor (SE7202 on the CM-077
board) peripheral circuits.
Inspect yaw angular velocity sensor (SE7201 on the CM-077
board) peripheral circuits.
Refer to [1-7-1. E : 62 : 02 (Abnormality of IC for Steadyshot)
Occurred].
Inspect the steadyshot circuit (IC5703 on the LD-221 board).
Refer to [1-7-2. E : 62 : 10 (Shift Lens Initializing Failure)
Occurred].
Refer to [1-7-3. E : 62 : 11 (Shift Lens Overheating (Pitch))
Occurred].
Refer to [1-7-4. E : 62 : 12 (Shift Lens Overheating (Yaw))
Occurred].
Refer to [1-7-5. E : 62 : 20 (Abnormality of Thermistor)
Occurred].
Checking of flash unit or replacement of flash unit. (Note)
1-6. PROCESS  AFTER  FIXING  FLASH  ERROR
When “FLASH error” (Self-diagnosis Code E:91:**) occurs, to prevent any abnormal situation caused by high voltage, setting of the flash
is changed automatically to disabling charge and flash setting.
After fixing, this setting needs to be deactivated. Connect the adjustment remote commander (RM-95 or NEW LANC JIG) and perform the
following process.
Order Page Address Data
Procedure
1
7
01
75
2
7
00
01
Press PAUSE (Write) button.
3
7
02
Check the data changes to “01”.
Note:
After repair, be sure to perform “1-6. PROCESS AFTER FIXING FLASH ERROR”.
1-5
ENGLISH
JAPANESE
ENGLISH
JAPANESE
HDR-HC9/HC9E_L2
1-7. METHOD OF COPING WITH SHIFT LENS ERROR
about 330 msec
Fig. 1
Measurement points on the LD-221 board
IC5703
R5737
R5792
R5721
LD-221 BOARD (SIDE A)
Fig. 2
Change in output voltage of R5792 on the LD-221 board
Note: The length of low section will vary a little depending on the
conditions.
1-7-1. E : 62 : 02 [Abnormality of IC for Steadyshot] Occurred
Order
Procedure
1
Turn the power OFF.
2
While measuring with an oscilloscope the output voltage of R5792 in the periphery of IC5703 on the LD-221 board, turn the
power ON to check that the output voltage immediately after the power on change as shown in Fig. 2.
3
If the output voltage change as shown in Fig. 2, replace the lens block (Note). If it does not change as shown in Fig. 2, inspect
the camera control circuit (IC1801 of VC-500 board) periphery.
Note: When the lens block was replaced, execute a necessary adjustment items referring to Service Manual, ADJ.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the
handheld operation.
IC1801
R1823
IC1801
R1823
VC-500 BOARD (SIDE A)
Fig. 3
Measurement points on the VC-500 board