Sony HDR-HC1 / HDR-HC1E / HDR-HC1EK / HDR-HC1K (serv.man4) Service Manual ▷ View online

6-71
HDR-HC1/HC1E/HC1K/HC1EK_ADJ
3-4.
VIDEO SYSTEM ADJUSTMENTS
Before perform the video system adjustments, check that the speci-
fied values of “36 MHz Origin Oscillation Adjustment” of “1-3.
CAMERA SYSTEM ADJUSTMENTS” is satisfied.
Check that the data of page: 0, address: 10 is “00”.
If not, select page: 0, address: 10, and set the data “00”.
Adjusting Procedure:
1. S VIDEO OUT Y level adjustment
2. S VIDEO OUT chroma level adjustment
3. VIDEO OUT level check
4. COMPONENT OUT Y level adjustment
5. COMPONENT OUT Pr level adjustment
6. COMPONENT OUT Pb level adjustment
Fig. 6-3-3
H
A
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
3
0C
02
Press PAUSE button.
3
Wait for 5 sec.
4
3
11
Check the bit value of bit5 is
“1”. (Note 2)
5
C
Change the data and set the Y
signal level (A) to the
specified value.
6
C
Press PAUSE button.
7
3
0C
00
Press PAUSE button.
8
0
01
00
Note 2: For the bit values, refer to “6-4. SERVICE MODE”, “4-
3. 3. Bit value discrimination”.
(NTSC)
25
(PAL)
85
(NTSC)
25
(PAL)
85
1.
S VIDEO OUT Y Level Adjustment (TT-001 board)
Mode
CAMERA-TAPE
Subject
Arbitrary
Measurement Point
Y signal terminal of S VIDEO plug
of A/V jack (75 
Ω terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
25 (NTSC)
85 (PAL)
Specified value
A = 1000 
± 14 mVp-p
Note 1: Check that the data of page: 0, address: 10 is “00”.
Switch setting:
1)
DEMO MODE (Menu setting) ......................................  OFF
6-72
HDR-HC1/HC1E/HC1K/HC1EK_ADJ
2.
S VIDEO OUT Chroma Level Adjustment
(TT-001 board)
Mode
CAMERA-TAPE
Subject
Arbitrary
Measurement Point
Chroma signal terminal of S VIDEO
plug of A/V jack (75 
Ω terminated)
External trigger: Y signal terminal of
S VIDEO plug of A/V jack (75 
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
26, 27 (NTSC)
86, 87 (PAL)
  Specified value
Cr level: A = 714 
± 14 mVp-p(NTSC)
A = 700 
± 14 mVp-p(PAL)
Cb level: B = 714 
± 14 mVp-p(NTSC)
B = 700 
± 14 mVp-p(PAL)
Burst level: C = 286 
± 6 mVp-p(NTSC)
   C = 300 
± 6 mVp-p(PAL)
Note 1: Check that the data of page: 0, address: 10 is “00”.
Switch setting:
1) DEMO MODE (Menu setting) ........................................ OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
3
0C
02
Press PAUSE button.
3
Wait for 5 sec.
4
3
11
Check the bit value of bit5 is
“1”. (Note 2)
5
C
Change the data and set the
Cr signal level (A) to the
specified value.
6
C
Press PAUSE button.
7
C
Change the data and set the
Cb signal level (B) to the
specified value.
8
C
Press PAUSE button.
9
Check the burst signal (C) to
the specified value.
10
3
0C
00
11
0
01
00
Note 2: For the bit values, refer to “6-4. SERVICE MODE”, “4-
3. 3. Bit value discrimination”.
H
A
0.28
µsec (NTSC)
B
0.28
µsec (NTSC)
0.23
µsec (PAL)
0.23
µsec (PAL)
C
Fig. 6-3-4
(NTSC)
26
(PAL)
86
(NTSC)
26
(PAL)
86
(NTSC)
27
(PAL)
87
(NTSC)
27
(PAL)
87
6-73
HDR-HC1/HC1E/HC1K/HC1EK_ADJ
3.
VIDEO OUT Level Check (TT-001 board)
Mode
CAMERA-TAPE
Subject
Arbitrary
Measurement Point
Video terminal of A/V jack (75 
terminated)
Measuring Instrument
Oscilloscope
Specified value
Sync level: A = 286 
± 18 mVp-p(NTSC)
A = 300 
± 18 mVp-p(PAL)
Burst level: B = 286 
± 18 mVp-p(NTSC)
B = 300 
± 18 mVp-p(PAL)
Note: Check that the data of page: 0, address: 10 is “00”.
Switch setting:
1) DEMO MODE (Menu setting) ........................................ OFF
Checking method:
Order Page Address Data
Procedure
1
3
0C
02
2
Wait for 5 sec.
3
3
11
Check the bit value of bit5 is
“1”. (Note 2)
4
Check the sync signal level
(A) to the specified value.
5
Check the burst signal level
(B) to the specified value.
6
3
0C
00
Note 2: For the bit values, refer to “6-4. SERVICE MODE”, “4-
3. 3. Bit value discrimination”.
Fig. 6-3-5
H
B
A
4.
COMPONENT OUT Y Level Adjustment
(TT-001 board)
Mode
CAMERA-TAPE
Subject
Arbitrary
Measurement Point
Y signal terminal of COMPONENT
OUT jack (75 
Ω terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
82
Specified value
Y level: A = 1000 
± 10 mVp-p
Sync level: B = C = 300 
± 10 mVp-p
Note 1: Check that the data of page: 0, address: 10 is “00”.
Switch setting:
1) DEMO MODE (Menu setting) ........................................ OFF
2) REC FORMAT (Menu setting) ............................. HDV1080i
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
01
3
8
01
Set the bit value of bit2 is
“1”, and press PAUSE
(18)
button.
4
0
10
00
5
C
82
Change the data and set the
Cr signal level (A) to the
specified value.
6
C
82
Press PAUSE button.
7
Check the sync signal (B, C)
to the specified value.
8
0
10
01
9
8
01
Set the bit value of bit2 is
“0”, and press PAUSE
(18)
button.
10
0
10
00
11
0
01
00
Note 2: For the bit values, refer to “6-4. SERVICE MODE”, “4-
3. 3. Bit value discrimination”.
H
A
C
B
Fig. 6-3-6
6-74
HDR-HC1/HC1E/HC1K/HC1EK_ADJ
5.
COMPONENT OUT Pr Level Adjustment
(TT-001 board)
Mode
CAMERA-TAPE
Subject
Arbitrary
Measurement Point
Pr signal terminal of COMPONENT
OUT jack (75 
Ω terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
83
Specified value
Pr level: A = 525 
± 10 mVp-p
Sync level: B = C = 300 
± 10 mVp-p
Note 1: Check that the data of page: 0, address: 10 is “00”.
Switch setting:
1) DEMO MODE (Menu setting) ........................................ OFF
2) REC FORMAT (Menu setting) ............................. HDV1080i
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
01
3
8
01
Set the bit value of bit2 is
“1”, and press PAUSE
(18)
button.
4
0
10
00
5
C
83
Change the data and set the
Pr signal level (A) to the
specified value.
6
C
83
Press PAUSE button.
7
Check the sync signal (B, C)
to the specified value.
8
0
10
01
9
8
01
Set the bit value of bit2 is
“0”, and press PAUSE
(18)
button.
10
0
10
00
11
0
01
00
Note 2: For the bit values, refer to “6-4. SERVICE MODE”, “4-
3. 3. Bit value discrimination”.
H
A
C
B
Fig. 6-3-7
6.
COMPONENT OUT Pb Level Adjustment
(TT-001 board)
Mode
CAMERA-TAPE
Subject
Arbitrary
Measurement Point
Pb signal terminal of COMPONENT
OUT jack (75 
Ω terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
84
Specified value
Pb level: A = 525 
± 10 mVp-p
Sync level: B = C = 300 
± 10 mVp-p
Note 1: Check that the data of page: 0, address: 10 is “00”.
Switch setting:
1) DEMO MODE (Menu setting) ........................................ OFF
2) REC FORMAT (Menu setting) ............................. HDV1080i
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
01
3
8
01
Set the bit value of bit2 is
“1”, and press PAUSE
(18)
button.
4
0
10
00
5
C
84
Change the data and set the
Pb signal level (A) to the
specified value.
6
C
84
Press PAUSE button.
7
Check the sync signal (B, C)
to the specified value.
8
0
10
01
9
8
01
Set the bit value of bit2 is
“0”, and press PAUSE
(18)
button.
10
0
10
00
11
0
01
00
Note 2: For the bit values, refer to “6-4. SERVICE MODE”, “4-
3. 3. Bit value discrimination”.
H
A
C
B
Fig. 6-3-8
Page of 91
Display

Click on the first or last page to see other HDR-HC1 / HDR-HC1E / HDR-HC1EK / HDR-HC1K (serv.man4) service manuals if exist.