Device
Movie / SECTION 6 ADJUSTMENTS
File
hdr-fx1-hdr-fx1e-sm3.pdf
Date

Sony HDR-FX1 / HDR-FX1E (serv.man3) Service Manual ▷ View online

6-6
HDR-FX1/FX1E
Fig. 6-1-3.
Adjustment remote
commander (RM-95)
LANC jack
AC power
adaptor 
AC IN
DC-IN
Screw (M2x4)
CPC lid
CPC-8 jig
(J-6082-388-A)
[CONNECTION OF EQUIPMENT]
6-7
HDR-FX1/FX1E
White
Black
841mm
1189mm
1-1-3.
Precaution
1. Setting the Switch
Unless otherwise specified, set the switches as follows and perform adjustments without loading cassette.
1.
POWER switch (PS5610 block) ............................ CAMERA
2.
FOCUS switch (CK-143 block) ............................ MANUAL
3.
ND FILTER switch (Lens block) ..................................... OFF
4.
ZOOM RING/LEVER switch (Lens block) .............. LEVER
5.
AUTO LOCK switch (FP-966 flexible) ............................ ON
6.
BACK LIGHT switch (FP-961 flexible) .......................... OFF
7.
SPOT LIGHT switch (FP-961 flexible) ........................... OFF
8.
BARS switch (FK-090 board) .......................................... OFF
9.
ZEBRA switch (MK-017 board) ..................................... OFF
10. MENU settings
CAMERA SET menu
STEADY SHOT ....................................................... OFF
IN/OUT REC. menu
REC FORMAT .............................................. HDV1080i
COMPONENT ....................................................... 1080i
TV TYPE .................................................................. 16:9
2. Order of Adjustments
Basically carry out adjustments in the order given.
Fig.6-1-4.
3. Subjects
1)
Color bar chart (HD color bar standard picture frame)
When performing adjustments using the color bar chart, adjust
the picture frame as shown in Fig. 6-1-4. (Color reproduction
adjustment frame)
2)
Clear chart (HD color bar standard picture frame)
Remove the color bar chart from the pattern box and insert a
clear chart in its place. (Do not perform zoom operations during
this time.)
3)
Flange back adjustment chart
Make the chart shown in Fig. 6-1-5 using A0 size (1189mm 
×
841mm) black and white vellum paper.
Electronic beam scanning frame
CRT picture frame
Yellow
Green
White
Magenta
Red
Blue
H
A=B
C=0, D=0
B
B
A
A
Cyan
Red
Yellow
Cyan
Green
White
Magenta
Blue
Difference in level
Enrargement
A
B
C
D
V
Color bar chart (HD color bar standard picture frame)
Fig. a
(Component output terminal
Y signal output waveform)
Fig. b (HD TV monitor picture)
Adjust the camera zoom and direction to obtain
the output waveform shown in Fig. a and the
HD TV monitor display shown in Fig. b.
Fig. 6-1-5.
Note: Use matte vellum paper bigger than A0, and make sure the edges of
the black and white paper joined together are not rough.
6-8
HDR-FX1/FX1E
1-2.
INITIALIZATION OF 8, 9, A, B, C, D, E, F, 13,
14, 18, 19, 1A, 1B, 1C, 1D, 1E, 1F PAGE DATA
Note: When reading or writing the 13, 14, 18, 19, 1A, 1B, 1C, 1D, 1E, 1F
page data, select page: 0, address: 10, and set data: 01, then select 3,
4, 8, 9, A, B, C, D, E or F page. The 13, 14, 18, 19, 1A, 1B, 1C, 1D,
1E or 1F page can be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1-2-1.
INITIALIZATION OF A, B, D, 1A, 1B PAGE DATA
Note: When reading or writing the A, B, D page data, select page: 0,
address: 10, and set data: 00.
When reading or writing the 1A or 1B page data, select page: 0,
address: 10, and set data: 01, then select A or B page. The 1A or 1B
page can be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1. Initializing the A, B, D, 1A, 1B Page Data
Note1: If the A, B, D, 1A, 1B page data has been initialized, the following
adjustments need to be performed again.
1) Modification of A, B, D, 1A, 1B page data
Adjusting page
A
Adjusting Address
10 to FF
Adjusting page
B
Adjusting Address
00 to FF
Adjusting page
D
Adjusting Address
10 to 7A
Adjusting page
1A
Adjusting Address
00 to FF
Adjusting page
1B
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
7
04
Set the following data.
00 (HDR-FX1 (NTSC))
01 (HDR-FX1E (PAL))
4
7
01
XX
Set the data. (Note2)
5
7
00
01
Set the data, and press PAUSE
button. (Note2)
6
7
02
Check that the data changes to
“01”
7
Perform “Modification of A, B,
D, 1A, 1B Page Data”.
Note2: XX=20: Initializing A page
XX=21: Initializing B page
XX=22: Initializing D page
XX=23: Initializing 1A page
XX=24: Initializing 1B page
XX=25: Initializing A and 1A page
XX=26: Initializing B and 1B page
XX=28: Initializing A, B, D, 1A and 1B page
2. Modification of A, B, D, 1A, 1B Page Data
If the A, B, D, 1A, 1B page data has been initialized, change the
data of the “Fixed data-2” address shown in the following tables by
manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
When changing the A, B, D page data, select page: 0, address:
10, and set data: 00.
3)
When changing the 1A, 1B page data, select page: 0, address:
10, and set data: 01.
After completing the modification of 1A, 1B page data, reset
the data of this address to “00”.
4)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
5)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
Processing after Completing Modification of A, B, D, 1A, 1B Page data
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
2
00
29
Set the data.
3
2
01
29
Set the data, and press PAUSE
button.
Note: If the following symptoms occur after completing of the
“Modification of A, B, D, 1A, 1B page data”, check that the data of
addresses: 1A to 4F of A page and the data of addresses: 12 to 19 of
D page are same as those of the same model of the same destination.
1) The self-diagnosis code “E:20:00” on the LCD screen is displayed.
2) The power is shut off so that unit cannot operate.
3. A Page Table
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the A, B,
D, 1A, 1B Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, B,
D, 1A, 1B Page Data”).
Address
Remark
Initial value
Address
Remark
Initial value
00 to 0F
10
11 to 17
18
19 to 2E
2F
30
31
32 to FF
00
Test mode
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Table. 6-1-2.
6-9
HDR-FX1/FX1E
4. B Page Table
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the A, B,
D, 1A, 1B Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, B,
D, 1A, 1B Page Data”).
Table. 6-1-3.
5. D Page Table
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the A, B,
D, 1A, 1B Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, B,
D, 1A, 1B Page Data”).
Address
00 to FF
Remark
Fixed data-1
Address
00 to 0F
10 to 15
16
17 to 27
28
29
2A
2B
2C
2D
2E
2F
30
31 to 32
33
34 to 56
57
58 to 79
7A
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
6. 1A Page Table
Note1: When reading or writing the 1A page data, select page: 0, address:
10, and set data: 01, then select A page. The 1A page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the A, B,
D, 1A, 1B Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, B,
D, 1A, 1B Page Data”).
Address
00 to C4
C5
C6 to CE
CF
D0 to D3
D4
D5
D6
D7 to D8
D9
DA to D0
DE
DF to E2
E3
E4 to EC
ED
EE to F1
F2
F3
F4
F5 to F6
F7
F8 to FB
FC
FD to FF
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Table. 6-1-5.
7. 1B Page Table
Note1: When reading or writing the 1B page data, select page: 0, address:
10, and set data: 01, then select B page. The 1B page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the A, B,
D, 1A, 1B Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, B,
D, 1A, 1B Page Data”).
Table. 6-1-6.
Address
00 to FF
Remark
Fixed data-1
Table. 6-1-4.
Page of 86
Display

Click on the first or last page to see other HDR-FX1 / HDR-FX1E (serv.man3) service manuals if exist.