Movie / SECTION 6 ADJUSTMENTS
File
hdr-fx1-hdr-fx1e-sm3.pdf
Date

Sony HDR-FX1 / HDR-FX1E (serv.man3) Service Manual ▷ View online

6-34
HDR-FX1/FX1E
22. White Balance Check ND OFF
Subject
Clear chart
(HD color bar standard picture frame)
Filter
Filter C14 for color temperature
correction
ND filter 1.0 and 0.4 and 0.1
Measurement Point
COMPONENT
Display data of
connector
page 1 (Note2)
Measuring Instrument
Vectorscope
Adjustment remote
(LV5152)
commander
Specified Value 1
Fig. 6-1-13 (A)
Specified Value 2
Fig. 6-1-13 (B)
Specified Value 3
8000 to 8B80
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Displayed data of the adjustment remote commander.
1 : XX : XX
Display data
Switch setting:
1)
REC FORMAT (IN/OUT REC menu) .................. HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2)
ND FILTER ...................................................................... OFF
(Page: 6, Address: 9B, Bit4=0, Bit5=0)
3)
STEADY SHOT (CAMERA SET menu) ........................ OFF
4)
FOCUS .................................................................. MANUAL
5
ZOOM ........................................................................ LEVER
Checking method:
Order Page Address Data
Procedure
Indoor white balance check
1
Check that the lens is not
covered with either filter.
2
6
01
0F
Set the data, and press PAUSE
button.
3
6
C9
10
Set the data, and press PAUSE
button.
4
Check that the center of the
white luminance point is within
the circle shown Fig. 6-1-13 (A)
5
6
01
00
Set the data, and press PAUSE
button.
Outdoor white balance check
6
Place the C14 filter on the lens.
7
6
01
3F
Set the data, and press PAUSE
button.
8
6
C9
10
Set the data, and press PAUSE
button.
9
Check that the center of the
white luminance point is within
the circle shown Fig. 6-1-13 (B)
10
Remove the C14 filter.
11
6
01
00
Set the data, and press PAUSE
button.
LV data check
12
Place the ND filter 1.5
(1.0+0.1+0.4) on the lens.
13
6
01
23
Set the data, and press PAUSE
button.
14
0
03
06
Set the data.
15
1
Check that the display data
(Note2) satisfies the specified
value3.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
C9
00
Set the data, and press PAUSE
button.
3
0
03
00
Set the data.
4
Remove the ND filter.
R-Y
2mm
B-Y
2mm
Fig. 6-1-13 (A).
Fig. 6-1-13 (B).
R-Y
B-Y
0.5mm
1mm
3mm
3mm
6-35
HDR-FX1/FX1E
23. White Balance Check ND 1
Subject
Clear chart
(HD color bar standard picture frame)
Filter
Filter C14 for color temperature
correction
ND filter 1.0 and 0.4 and 0.1
Measurement Point
COMPONENT
Display data of
connector
page 1 (Note2)
Measuring Instrument
Vectorscope
Adjustment remote
(LV5152)
commander
Specified Value 1
Fig. 6-1-14 (A)
Specified Value 2
Fig. 6-1-14 (B)
Specified Value 3
8000 to 8B80
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Displayed data of the adjustment remote commander.
1 : XX : XX
Display data
Switch setting:
1)
REC FORMAT (IN/OUT REC menu) .................. HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2)
ND FILTER ........................................................................... 1
(Page: 6, Address: 9B, Bit4=1, Bit5=0)
3)
STEADY SHOT (CAMERA SET menu) ........................ OFF
4)
FOCUS .................................................................. MANUAL
5
ZOOM ........................................................................ LEVER
Fig. 6-1-14 (A).
Fig. 6-1-14 (B).
Checking method:
Order Page Address Data
Procedure
1
Set ND FILTRE switch to “1”.
Indoor white balance check
2
Check that the lens is not
covered with either filter.
3
6
01
0F
Set the data, and press PAUSE
button.
4
6
C9
10
Set the data, and press PAUSE
button.
5
Check that the center of the
white luminance point is within
the circle shown Fig. 6-1-14 (A)
6
6
01
00
Set the data, and press PAUSE
button.
Outdoor white balance check
7
Place the C14 filter on the lens.
8
6
01
3F
Set the data, and press PAUSE
button.
9
6
C9
10
Set the data, and press PAUSE
button.
10
Check that the center of the
white luminance point is within
the circle shown Fig. 6-1-14 (B)
11
Remove the C14 filter.
12
6
01
00
Set the data, and press PAUSE
button.
LV data check
13
Place the ND filter 1.5
(1.0+0.1+0.4) on the lens.
14
6
01
23
Set the data, and press PAUSE
button.
15
0
03
06
Set the data.
16
1
Check that the display data
(Note2) satisfies the specified
value3.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
C9
00
Set the data, and press PAUSE
button.
3
0
03
00
Set the data.
4
Remove the ND filter.
5
Set ND FILTRE switch to
“OFF”.
R-Y
2mm
B-Y
2mm
R-Y
B-Y
0.5mm
1mm
3mm
3mm
6-36
HDR-FX1/FX1E
24. White Balance Check ND 2
Subject
Clear chart
(HD color bar standard picture frame)
Filter
Filter C14 for color temperature
correction
Measurement Point
COMPONENT connector
Measuring Instrument
Vectorscope (LV5152)
Specified Value 1
Fig. 6-1-15 (A)
Specified Value 2
Fig. 6-1-15 (B)
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Displayed data of the adjustment remote commander.
1 : XX : XX
Display data
Switch setting:
1)
REC FORMAT (IN/OUT REC menu) .................. HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2)
ND FILTER ........................................................................... 2
(Page: 6, Address: 9B, Bit4=0, Bit5=1)
3)
STEADY SHOT (CAMERA SET menu) ........................ OFF
4)
FOCUS .................................................................. MANUAL
5
ZOOM ........................................................................ LEVER
Fig. 6-1-15 (A).
Fig. 6-1-15 (B).
Checking method:
Order Page Address Data
Procedure
1
Set ND FILTRE switch to “2”.
Indoor white balance check
2
Check that the lens is not
covered with either filter.
3
6
01
0F
Set the data, and press PAUSE
button.
4
6
C9
10
Set the data, and press PAUSE
button.
5
Check that the center of the
white luminance point is within
the circle shown Fig. 6-1-15 (A)
6
6
01
00
Set the data, and press PAUSE
button.
Outdoor white balance check
7
Place the C14 filter on the lens.
8
6
01
3F
Set the data, and press PAUSE
button.
9
6
C9
10
Set the data, and press PAUSE
button.
10
Check that the center of the
white luminance point is within
the circle shown Fig. 6-1-15 (B)
11
Remove the C14 filter.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
C9
00
Set the data, and press PAUSE
button.
3
Set ND FILTRE switch to
“OFF”.
R-Y
2mm
B-Y
2mm
R-Y
B-Y
0.5mm
1mm
3mm
3mm
6-37
HDR-FX1/FX1E
25. Color Reproduction Check
ND OFF HD STD 
γ
Subject
Color bar chart
(HD color bar standard picture frame)
Measurement Point
NTSC or PAL vectorscope: Video
terminal of AUDIO/VIDEO jack (Note3)
Measuring Instrument
Oscilloscope: COMPONENT
connector
Specified Value
All color luminance points should
settle within each color reproduction
frame (HD STD 
γ
). (Fig. 6-1-17.)
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note3: When using the vectorscope, disconnect the cable from the
COMPONENT connector.
Note4: NTSC model: HDR-FX1
PAL model: HDR-FX1E
Switch setting:
1)
REC FORMAT (IN/OUT REC menu) .................. HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2)
ND FILTER ...................................................................... OFF
(Page: 6, Address: 9B, Bit4=0, Bit5=0)
3)
STEADY SHOT (CAMERA SET menu) ........................ OFF
4)
FOCUS .................................................................. MANUAL
5)
ZOOM ........................................................................ LEVER
Adjusting method:
Order Page Address Data
Procedure
1
Set the color bar chart, and
check the picture frame.
(Refer to “10. Picture Frame
Setting”.)
2
0
01
01
Set the data.
3
6
01
4D
Set the data, and press PAUSE
button.
4
6
9D
Change the data and set the Y
signal level (A) to 630mV.
(Note5) (Fig. 6-1-16.)
5
6
9E
22
Set the data.
6
6
12
80
Set the data.
7
6
12
00
Set the data.
8
Check that the Y signal level (A)
is 630mV.
9
Check that each center of all
color luminance points is set in
each color reproduction frame.
Note5: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75 
.
(When the component video signals are not outputted, connect
the SW terminal (Pin q;) of the COMPONENT connector to
GND.)
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
9D
00
Set the data.
3
0
01
00
Set the data.
Fig. 6-1-16.
For HD STD 
γ
 mode
Fig. 6-1-17.
A
H
NTSC Burst position
PAL Burst position
Page of 86
Display