Movie / SECTION 6 ADJUSTMENTS
File
hdr-fx1-hdr-fx1e-sm3.pdf
Date

Sony HDR-FX1 / HDR-FX1E (serv.man3) Service Manual ▷ View online

6-30
HDR-FX1/FX1E
15. LV Standard Data Input
Adjust the normal coefficient of the light value.
Subject
Clear chart
(HD color bar standard picture frame)
Measurement Point
Display data of page 1 (Note4)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
1A, 1B
Specified Value
0FE0 to 1020
Note1: This adjustment should be carried out upon completion of “Auto
White Balance Standard Data Input”.
Note2: The data of page: 0, address: 10 must be “00”.
Note3: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note4: Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Display data
Switch setting:
1)
REC FORMAT (IN/OUT REC menu) .................. HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2)
ND FILTER ...................................................................... OFF
(Page: 6, Address: 9B, Bit4=0, Bit5=0)
3)
STEADY SHOT (CAMERA SET menu) ........................ OFF
4)
FOCUS .................................................................. MANUAL
5)
ZOOM ........................................................................ LEVER
Adjusting method:
Order Page Address Data
Procedure
1
Check the picture frame.
Refer to “10. Picture Frame
Setting”.)
2
0
01
01
Set the data.
3
6
30
01
Set the data.
4
6
C9
10
Set the data.
5
6
01
0D
Set the data, and press PAUSE
button.
6
6
02
Check that the data changes to
“01”. (Note5)
7
0
03
1E
Set the data.
8
1
Check that the display data
(Note4) satisfies the specified
value. (Note6)
Note5: The adjustment data will be automatically input to page: F, address:
1A, 1B.
Note6: If it isn’t satisfied, repeat the adjustment again.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
30
00
Set the data.
3
6
C9
00
Set the data.
4
0
03
00
Set the data.
5
0
01
00
Set the data.
16. Auto White Balance Adjustment ND OFF
Adjust to the proper auto white balance output data when the ND
filter switch is “OFF”.
If it is not correct, auto white balance and color reproducibility will
be poor.
Subject
Clear chart
(HD color bar standard picture frame)
Filter
Filter C14 for color temperature
correction
Adjustment Page
F
Adjustment Address
3C to 3F, 40 to 43
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
REC FORMAT (IN/OUT REC menu) .................. HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2)
ND FILTER ...................................................................... OFF
(Page: 6, Address: 9B, Bit4=0, Bit5=0)
3)
FOCUS .................................................................. MANUAL
4)
ZOOM ........................................................................ LEVER
Adjusting method:
Order Page Address Data
Procedure
1
Place the C14 filter for color
temperature correction on the
lens.
2
0
01
01
Set the data.
3
F
3C
2B
Set the data, and press PAUSE
button.
4
F
3D
E0
Set the data, and press PAUSE
button.
5
F
3E
58
Set the data, and press PAUSE
button.
6
F
3F
78
Set the data, and press PAUSE
button.
7
6
01
83
Set the data, and press PAUSE
button.
8
6
01
81
Set the data, and press PAUSE
button.
9
6
02
Check that the data changes to
“01”. (Note3)
Note3: The adjustment data will be automatically input to page: F, address:
40 to 43.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
0
01
00
Set the data.
3
Remove the C14 filter.
6-31
HDR-FX1/FX1E
17. Auto White Balance Adjustment ND 1
Adjust to the proper auto white balance output data when the ND
filter switch is “1”.
If it is not correct, auto white balance and color reproducibility will
be poor.
Subject
Clear chart
(HD color bar standard picture frame)
Filter
Filter C14 for color temperature
correction
Adjustment Page
F
Adjustment Address
3C to 3F, D0 to D3
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
REC FORMAT (IN/OUT REC menu) .................. HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2)
ND FILTER ........................................................................... 1
(Page: 6, Address: 9B, Bit4=1, Bit5=0)
3)
FOCUS .................................................................. MANUAL
4)
ZOOM ........................................................................ LEVER
Adjusting method:
Order Page Address Data
Procedure
1
Place the C14 filter for color
temperature correction on the
lens.
2
Set ND FILTRE switch to “1”.
3
0
01
01
Set the data.
4
F
3C
2B
Set the data, and press PAUSE
button.
5
F
3D
E0
Set the data, and press PAUSE
button.
6
F
3E
58
Set the data, and press PAUSE
button.
7
F
3F
78
Set the data, and press PAUSE
button.
8
6
01
83
Set the data, and press PAUSE
button.
9
6
01
81
Set the data, and press PAUSE
button.
10
6
02
Check that the data changes to
“01”. (Note3)
Note3: The adjustment data will be automatically input to page: F, address:
D0 to D3.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
0
01
00
Set the data.
3
Remove the C14 filter.
4
Set ND FILTRE switch to
“OFF”.
18. Auto White Balance Adjustment ND 2
Adjust to the proper auto white balance output data when the ND
filter switch is “2”.
If it is not correct, auto white balance and color reproducibility will
be poor.
Subject
Clear chart
(HD color bar standard picture frame)
Filter
Filter C14 for color temperature
correction
Adjustment Page
F
Adjustment Address
3C to 3F, D8 to DB
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
REC FORMAT (IN/OUT REC menu) .................. HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2)
ND FILTER ........................................................................... 2
(Page: 6, Address: 9B, Bit4=0, Bit5=1)
3)
FOCUS .................................................................. MANUAL
4)
ZOOM ........................................................................ LEVER
Adjusting method:
Order Page Address Data
Procedure
1
Place the C14 filter for color
temperature correction on the
lens.
2
Set ND FILTRE switch to “2”.
3
0
01
01
Set the data.
4
F
3C
2B
Set the data, and press PAUSE
button.
5
F
3D
E0
Set the data, and press PAUSE
button.
6
F
3E
58
Set the data, and press PAUSE
button.
7
F
3F
78
Set the data, and press PAUSE
button.
8
6
01
83
Set the data, and press PAUSE
button.
9
6
01
81
Set the data, and press PAUSE
button.
10
6
02
Check that the data changes to
“01”. (Note3)
Note3: The adjustment data will be automatically input to page: F, address:
D8 to DB.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
0
01
00
Set the data.
3
Remove the C14 filter.
4
Set ND FILTRE switch to
“OFF”.
6-32
HDR-FX1/FX1E
19. Color Reproduction Adjustment ND OFF
Adjust the hue and gain of R-Y and B-Y signals so that proper
color reproduction is produced when the ND filter switch is “OFF”.
Subject
Color bar chart
(HD color bar standard picture frame)
Measurement Point
COMPONENT connector
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
38 to 3B (HD)
B4 to B7 (SD)
C0 to C3 (HD CINE)
DC to DF (SD CINE)
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
REC FORMAT (IN/OUT REC menu) .................. HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2)
ND FILTER ...................................................................... OFF
(Page: 6, Address: 9B, Bit4=0, Bit5=0)
3)
FOCUS .................................................................. MANUAL
4)
ZOOM ........................................................................ LEVER
Adjusting method:
Order Page Address Data
Procedure
1
Set the color bar chart, and
check the picture frame.
(Refer to “10. Picture Frame
Setting”.)
2
0
01
01
Set the data.
3
6
01
4D
Set the data, and press PAUSE
button.
4
6
9D
Change the data and set the Y
signal level (A) to 630mV.
(Note3) (Fig. 6-1-12.)
5
6
9E
22
Set the data.
6
6
12
80
Set the data.
7
6
12
00
Set the data.
8
Check that the Y signal level (A)
is 630mV.
9
6
01
61
Set the data, and press PAUSE
button.
10
6
02
Check that the data changes to
“01”. (Note4)
Note3: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75 
.
(When the component video signals are not outputted, connect
the SW terminal (Pin q;) of the COMPONENT connector to
GND.)
Note4: The adjustment data will be automatically input to page: F, address:
38 to 3B, B4 to B7, C0 to C3, DC to DF.
Fig. 6-1-12.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
9D
00
Set the data.
3
0
01
00
Set the data.
A
H
6-33
HDR-FX1/FX1E
20. Color Reproduction Adjustment ND 1
Adjust the hue and gain of R-Y and B-Y signals so that proper
color reproduction is produced when the ND filter switch is “1”.
Subject
Color bar chart
(HD color bar standard picture frame)
Measurement Point
COMPONENT connector
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
AC to AF (HD)
B8 to BB (SD)
C4 to C7 (HD CINE)
E0 to E3 (SD CINE)
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
REC FORMAT (IN/OUT REC menu) .................. HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2)
ND FILTER ........................................................................... 1
(Page: 6, Address: 9B, Bit4=1, Bit5=0)
3)
FOCUS .................................................................. MANUAL
4)
ZOOM ........................................................................ LEVER
Adjusting method:
Order Page Address Data
Procedure
1
Set ND FILTRE switch to “1”.
2
0
01
01
Set the data.
3
6
01
4D
Set the data, and press PAUSE
button.
4
6
9D
Change the data and set the Y
signal level (A) to 630mV.
(Note3) (Fig. 6-1-12.)
5
6
9E
22
Set the data.
6
6
12
80
Set the data.
7
6
12
00
Set the data.
8
Check that the Y signal level (A)
is 630mV.
9
6
01
61
Set the data, and press PAUSE
button.
10
6
02
Check that the data changes to
“01”. (Note4)
Note3: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75 
.
Note4: The adjustment data will be automatically input to page: F, address:
AC to AF, B8 to BB, C4 to C7, E0 to E3.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
9D
00
Set the data.
3
0
01
00
Set the data.
4
Set ND FILTRE switch to
“OFF”.
21. Color Reproduction Adjustment ND 2
Adjust the hue and gain of R-Y and B-Y signals so that proper
color reproduction is produced when the ND filter switch is “2”.
Subject
Color bar chart
(HD color bar standard picture frame)
Measurement Point
COMPONENT connector
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
B0 to B3 (HD)
BC to BF (SD)
C8 to CB (HD CINE)
E4 to E7 (SD CINE)
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
REC FORMAT (IN/OUT REC menu) .................. HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2)
ND FILTER ........................................................................... 2
(Page: 6, Address: 9B, Bit4=0, Bit5=1)
3)
FOCUS .................................................................. MANUAL
4)
ZOOM ........................................................................ LEVER
Adjusting method:
Order Page Address Data
Procedure
1
Set ND FILTRE switch to “2”.
2
0
01
01
Set the data.
3
6
01
4D
Set the data, and press PAUSE
button.
4
6
9D
Change the data and set the Y
signal level (A) to 630mV.
(Note3) (Fig. 6-1-12.)
5
6
9E
22
Set the data.
6
6
12
80
Set the data.
7
6
12
00
Set the data.
8
Check that the Y signal level (A)
is 630mV.
9
6
01
61
Set the data, and press PAUSE
button.
10
6
02
Check that the data changes to
“01”. (Note4)
Note3: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75 
.
Note4: The adjustment data will be automatically input to page: F, address:
B0 to B3, BC to BF, C8 to CB, E4 to E7.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
9D
00
Set the data.
3
0
01
00
Set the data.
4
Set ND FILTRE switch to
“OFF”.
Page of 86