6-38
HDR-FX1/FX1E
26. Color Reproduction Check ND 1 HD STD
γ
Subject
Color bar chart
(HD color bar standard picture frame)
(HD color bar standard picture frame)
Measurement Point
NTSC or PAL vectorscope: Video
terminal of AUDIO/VIDEO jack (Note3)
terminal of AUDIO/VIDEO jack (Note3)
Measuring Instrument
Oscilloscope: COMPONENT
connector
connector
Specified Value
All color luminance points should
settle within each color reproduction
frame (HD STD
settle within each color reproduction
frame (HD STD
γ
). (Fig. 6-1-17.)
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Check that the data of page: 6, address: 02 is “00”. If not, to page:
Note2: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note3: When using the vectorscope, disconnect the cable from the
COMPONENT connector.
Switch setting:
1)
1)
REC FORMAT (IN/OUT REC menu ................... HDV1080i
(Page: 6, Address: 9B, Bit2=0)
(Page: 6, Address: 9B, Bit2=0)
2)
ND FILTER ........................................................................... 1
(Page: 6, Address: 9B, Bit4=1, Bit5=0)
(Page: 6, Address: 9B, Bit4=1, Bit5=0)
3)
STEADY SHOT (CAMERA SET menu) ........................ OFF
4)
FOCUS .................................................................. MANUAL
5)
ZOOM ........................................................................ LEVER
Adjusting method:
Order Page Address Data
Procedure
1
Set ND FILTRE switch to “1”.
2
0
01
01
Set the data.
3
6
01
4D
Set the data, and press PAUSE
button.
button.
4
6
9D
Change the data and set the Y
signal level (A) to 630mV.
(Note4) (Fig. 6-1-16.)
signal level (A) to 630mV.
(Note4) (Fig. 6-1-16.)
5
6
9E
22
Set the data.
6
6
12
80
Set the data.
7
6
12
00
Set the data.
8
Check that the Y signal level (A)
is 630mV.
is 630mV.
9
Check that each center of all
color luminance points is set in
each color reproduction frame.
color luminance points is set in
each color reproduction frame.
Note4: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75
Ω
.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
button.
2
6
9D
00
Set the data.
3
0
01
00
Set the data.
4
Set ND FILTRE switch to
“OFF”.
“OFF”.
27. Color Reproduction Check ND 2 HD STD
γ
Subject
Color bar chart
(HD color bar standard picture frame)
(HD color bar standard picture frame)
Measurement Point
NTSC or PAL vectorscope: Video
terminal of AUDIO/VIDEO jack (Note3)
terminal of AUDIO/VIDEO jack (Note3)
Measuring Instrument
Oscilloscope: COMPONENT
connector
connector
Specified Value
All color luminance points should
settle within each color reproduction
frame (HD STD
settle within each color reproduction
frame (HD STD
γ
). (Fig. 6-1-17.)
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Check that the data of page: 6, address: 02 is “00”. If not, to page:
Note2: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note3: When using the vectorscope, disconnect the cable from the
COMPONENT connector.
Switch setting:
1)
1)
REC FORMAT (IN/OUT REC menu ................... HDV1080i
(Page: 6, Address: 9B, Bit2=0)
(Page: 6, Address: 9B, Bit2=0)
2)
ND FILTER ........................................................................... 2
(Page: 6, Address: 9B, Bit4=0, Bit5=1)
(Page: 6, Address: 9B, Bit4=0, Bit5=1)
3)
STEADY SHOT (CAMERA SET menu) ........................ OFF
4)
FOCUS .................................................................. MANUAL
5)
ZOOM ........................................................................ LEVER
Adjusting method:
Order Page Address Data
Procedure
1
Set ND FILTRE switch to “2”.
2
0
01
01
Set the data.
3
6
01
4D
Set the data, and press PAUSE
button.
button.
4
6
9D
Change the data and set the Y
signal level (A) to 630mV.
(Note4) (Fig. 6-1-16.)
signal level (A) to 630mV.
(Note4) (Fig. 6-1-16.)
5
6
9E
22
Set the data.
6
6
12
80
Set the data.
7
6
12
00
Set the data.
8
Check that the Y signal level (A)
is 630mV.
is 630mV.
9
Check that each center of all
color luminance points is set in
each color reproduction frame.
color luminance points is set in
each color reproduction frame.
Note4: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75
Ω
.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
button.
2
6
9D
00
Set the data.
3
0
01
00
Set the data.
4
Set ND FILTRE switch to
“OFF”.
“OFF”.
6-39
HDR-FX1/FX1E
28. Color Reproduction Check
ND OFF HD CINE
γ
Subject
Color bar chart
(HD color bar standard picture frame)
(HD color bar standard picture frame)
Measurement Point
NTSC or PAL vectorscope: Video
terminal of AUDIO/VIDEO jack (Note3)
terminal of AUDIO/VIDEO jack (Note3)
Measuring Instrument
Oscilloscope: COMPONENT
connector
connector
Specified Value
All color luminance points should
settle within each color reproduction
frame (HD CINE
settle within each color reproduction
frame (HD CINE
γ
). (Fig. 6-1-19.)
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Check that the data of page: 6, address: 02 is “00”. If not, to page:
Note2: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note3: When using the vectorscope, disconnect the cable from the
COMPONENT connector.
Note4: NTSC model: HDR-FX1
PAL model: HDR-FX1E
Switch setting:
1)
1)
REC FORMAT (IN/OUT REC menu) .................. HDV1080i
(Page: 6, Address: 9B, Bit2=0)
(Page: 6, Address: 9B, Bit2=0)
2)
ND FILTER ...................................................................... OFF
(Page: 6, Address: 9B, Bit4=0, Bit5=0)
(Page: 6, Address: 9B, Bit4=0, Bit5=0)
3)
STEADY SHOT (CAMERA SET menu) ........................ OFF
4)
FOCUS .................................................................. MANUAL
5)
ZOOM ........................................................................ LEVER
Adjusting method:
Order Page Address Data
Procedure
1
Set ND FILTRE switch to
“OFF”.
“OFF”.
2
0
01
01
Set the data.
3
6
8A
04
Set the data.
4
6
9B
Check that bit3 is “1”. (Note5)
5
6
01
4D
Set the data, and press PAUSE
button.
button.
6
6
9D
Change the data and set the Y
signal level (A) to 500mV.
(Note6) (Fig. 6-1-18.)
signal level (A) to 500mV.
(Note6) (Fig. 6-1-18.)
7
6
9E
22
Set the data.
8
6
12
80
Set the data.
9
6
12
00
Set the data.
10
Check that the Y signal level (A)
is 500mV.
is 500mV.
11
Check that each center of all
color luminance points is set in
each color reproduction frame.
color luminance points is set in
each color reproduction frame.
Note5: For the bit values, refer to “6-4. SERVICE MODE”, “4-3. 3. Bit
value discrimination”.
Note6: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75
Ω
.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
button.
2
6
8A
00
Set the data.
3
6
9D
00
Set the data.
4
0
01
00
Set the data.
Fig. 6-1-18.
For HD CINE
γ
mode
Fig. 6-1-19.
H
A
NTSC Burst position
PAL Burst position
6-40
HDR-FX1/FX1E
29. Color Reproduction Check ND 1 HD CINE
γ
Subject
Color bar chart
(HD color bar standard picture frame)
(HD color bar standard picture frame)
Measurement Point
NTSC or PAL vectorscope: Video
terminal of AUDIO/VIDEO jack (Note3)
terminal of AUDIO/VIDEO jack (Note3)
Measuring Instrument
Oscilloscope: COMPONENT
connector
connector
Specified Value
All color luminance points should
settle within each color reproduction
frame (HD CINE
settle within each color reproduction
frame (HD CINE
γ
). (Fig. 6-1-19.)
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Check that the data of page: 6, address: 02 is “00”. If not, to page:
Note2: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note3: When using the vectorscope, disconnect the cable from the
COMPONENT connector.
Switch setting:
1)
1)
REC FORMAT (IN/OUT REC menu ................... HDV1080i
(Page: 6, Address: 9B, Bit2=0)
(Page: 6, Address: 9B, Bit2=0)
2)
ND FILTER ........................................................................... 1
(Page: 6, Address: 9B, Bit4=1, Bit5=0)
(Page: 6, Address: 9B, Bit4=1, Bit5=0)
3)
STEADY SHOT (CAMERA SET menu) ........................ OFF
4)
FOCUS .................................................................. MANUAL
5)
ZOOM ........................................................................ LEVER
Adjusting method:
Order Page Address Data
Procedure
1
Set ND FILTRE switch to “1”.
2
0
01
01
Set the data.
3
6
8A
04
Set the data.
4
6
9B
Check that bit3 is “1”. (Note4)
5
6
01
4D
Set the data, and press PAUSE
button.
button.
6
6
9D
Change the data and set the Y
signal level (A) to 500mV.
(Note5) (Fig. 6-1-18.)
signal level (A) to 500mV.
(Note5) (Fig. 6-1-18.)
7
6
9E
22
Set the data.
8
6
12
80
Set the data.
9
6
12
00
Set the data.
10
Check that the Y signal level (A)
is 500mV.
is 500mV.
11
Check that each center of all
color luminance points is set in
each color reproduction frame.
color luminance points is set in
each color reproduction frame.
Note4: For the bit values, refer to “6-4. SERVICE MODE”, “4-3. 3. Bit
value discrimination”.
Note5: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75
Ω
.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
button.
2
6
8A
00
Set the data.
3
6
9D
00
Set the data.
4
0
01
00
Set the data.
5
Set ND FILTRE switch to
“OFF”.
“OFF”.
30. Color Reproduction Check ND 2 HD CINE
γ
Subject
Color bar chart
(HD color bar standard picture frame)
(HD color bar standard picture frame)
Measurement Point
NTSC or PAL vectorscope: Video
terminal of AUDIO/VIDEO jack (Note3)
terminal of AUDIO/VIDEO jack (Note3)
Measuring Instrument
Oscilloscope: COMPONENT
connector
connector
Specified Value
All color luminance points should
settle within each color reproduction
frame (HD CINE
settle within each color reproduction
frame (HD CINE
γ
). (Fig. 6-1-19.)
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Check that the data of page: 6, address: 02 is “00”. If not, to page:
Note2: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note3: When using the vectorscope, disconnect the cable from the
COMPONENT connector.
Switch setting:
1)
1)
REC FORMAT (IN/OUT REC menu ................... HDV1080i
(Page: 6, Address: 9B, Bit2=0)
(Page: 6, Address: 9B, Bit2=0)
2)
ND FILTER ........................................................................... 2
(Page: 6, Address: 9B, Bit4=0, Bit5=1)
(Page: 6, Address: 9B, Bit4=0, Bit5=1)
3)
STEADY SHOT (CAMERA SET menu) ........................ OFF
4)
FOCUS .................................................................. MANUAL
5)
ZOOM ........................................................................ LEVER
Adjusting method:
Order Page Address Data
Procedure
1
Set ND FILTRE switch to “2”.
2
0
01
01
Set the data.
3
6
8A
04
Set the data.
4
6
9B
Check that bit3 is “1”. (Note4)
5
6
01
4D
Set the data, and press PAUSE
button.
button.
6
6
9D
Change the data and set the Y
signal level (A) to 500mV.
(Note5) (Fig. 6-1-18.)
signal level (A) to 500mV.
(Note5) (Fig. 6-1-18.)
7
6
9E
22
Set the data.
8
6
12
80
Set the data.
9
6
12
00
Set the data.
10
Check that the Y signal level (A)
is 500mV.
is 500mV.
11
Check that each center of all
color luminance points is set in
each color reproduction frame.
color luminance points is set in
each color reproduction frame.
Note4: For the bit values, refer to “6-4. SERVICE MODE”, “4-3. 3. Bit
value discrimination”.
Note5: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75
Ω
.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
button.
2
6
8A
00
Set the data.
3
6
9D
00
Set the data.
4
0
01
00
Set the data.
5
Set ND FILTRE switch to
“OFF”
“OFF”
6-41
HDR-FX1/FX1E
31. Color Reproduction Check
ND OFF SD STD
γ
Subject
Color bar chart
(HD color bar standard picture frame)
(HD color bar standard picture frame)
Measurement Point
NTSC or PAL vectorscope: Video
terminal of AUDIO/VIDEO jack (Note3)
terminal of AUDIO/VIDEO jack (Note3)
Measuring Instrument
Oscilloscope: COMPONENT
connector
connector
Specified Value
All color luminance points should
settle within each color reproduction
frame (SD STD
settle within each color reproduction
frame (SD STD
γ
). (Fig. 6-1-21.)
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Check that the data of page: 6, address: 02 is “00”. If not, to page:
Note2: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note3: When using the vectorscope, disconnect the cable from the
COMPONENT connector.
Note4: NTSC model: HDR-FX1
PAL model: HDR-FX1E
Switch setting:
1)
1)
REC FORMAT (IN/OUT REC menu) .............................. DV
(Page: 6, Address: 9B, Bit2=1)
(Page: 6, Address: 9B, Bit2=1)
2)
ND FILTER ...................................................................... OFF
(Page: 6, Address: 9B, Bit4=0, Bit5=0)
(Page: 6, Address: 9B, Bit4=0, Bit5=0)
3)
STEADY SHOT (CAMERA SET menu) ........................ OFF
4)
FOCUS .................................................................. MANUAL
5)
ZOOM ........................................................................ LEVER
Adjusting method:
Order Page Address Data
Procedure
1
Set REC FORMAT to “DV”.
2
Set ND FILTRE switch to
“OFF”.
“OFF”.
3
0
01
01
Set the data.
4
6
01
4D
Set the data, and press PAUSE
button.
button.
5
6
9D
Change the data and set the Y
signal level (A) to 90 IRE.
(Note5) (Fig. 6-1-20.)
signal level (A) to 90 IRE.
(Note5) (Fig. 6-1-20.)
6
6
9E
22
Set the data.
7
6
12
80
Set the data.
8
6
12
00
Set the data.
9
Check that the Y signal level (A)
is 90 IRE.
is 90 IRE.
10
Check that each center of all
color luminance points is set in
each color reproduction frame.
color luminance points is set in
each color reproduction frame.
Note5: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75
Ω
.
90 IRE = 630 mV
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
button.
2
6
9D
00
Set the data.
3
0
01
00
Set the data.
Fig. 6-1-20.
For SD STD
γ
mode
Fig. 6-1-21.
H
A
NTSC Burst position
PAL Burst position
Click on the first or last page to see other HDR-FX1 / HDR-FX1E (serv.man3) service manuals if exist.