DOWNLOAD Sony HDR-FX1 / HDR-FX1E (serv.man3) Service Manual ↓ Size: 2.45 MB | Pages: 86 in PDF or view online for FREE

Model
HDR-FX1 HDR-FX1E (serv.man3)
Pages
86
Size
2.45 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
hdr-fx1-hdr-fx1e-sm3.pdf
Date

Sony HDR-FX1 / HDR-FX1E (serv.man3) Service Manual ▷ View online

6-38
HDR-FX1/FX1E
26. Color Reproduction Check ND 1 HD STD 
γ
Subject
Color bar chart
(HD color bar standard picture frame)
Measurement Point
NTSC or PAL vectorscope: Video
terminal of AUDIO/VIDEO jack (Note3)
Measuring Instrument
Oscilloscope: COMPONENT
connector
Specified Value
All color luminance points should
settle within each color reproduction
frame (HD STD 
γ
). (Fig. 6-1-17.)
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note3: When using the vectorscope, disconnect the cable from the
COMPONENT connector.
Switch setting:
1)
REC FORMAT (IN/OUT REC menu ................... HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2)
ND FILTER ........................................................................... 1
(Page: 6, Address: 9B, Bit4=1, Bit5=0)
3)
STEADY SHOT (CAMERA SET menu) ........................ OFF
4)
FOCUS .................................................................. MANUAL
5)
ZOOM ........................................................................ LEVER
Adjusting method:
Order Page Address Data
Procedure
1
Set ND FILTRE switch to “1”.
2
0
01
01
Set the data.
3
6
01
4D
Set the data, and press PAUSE
button.
4
6
9D
Change the data and set the Y
signal level (A) to 630mV.
(Note4) (Fig. 6-1-16.)
5
6
9E
22
Set the data.
6
6
12
80
Set the data.
7
6
12
00
Set the data.
8
Check that the Y signal level (A)
is 630mV.
9
Check that each center of all
color luminance points is set in
each color reproduction frame.
Note4: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75 
.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
9D
00
Set the data.
3
0
01
00
Set the data.
4
Set ND FILTRE switch to
“OFF”.
27. Color Reproduction Check ND 2 HD STD 
γ
Subject
Color bar chart
(HD color bar standard picture frame)
Measurement Point
NTSC or PAL vectorscope: Video
terminal of AUDIO/VIDEO jack (Note3)
Measuring Instrument
Oscilloscope: COMPONENT
connector
Specified Value
All color luminance points should
settle within each color reproduction
frame (HD STD 
γ
). (Fig. 6-1-17.)
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note3: When using the vectorscope, disconnect the cable from the
COMPONENT connector.
Switch setting:
1)
REC FORMAT (IN/OUT REC menu ................... HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2)
ND FILTER ........................................................................... 2
(Page: 6, Address: 9B, Bit4=0, Bit5=1)
3)
STEADY SHOT (CAMERA SET menu) ........................ OFF
4)
FOCUS .................................................................. MANUAL
5)
ZOOM ........................................................................ LEVER
Adjusting method:
Order Page Address Data
Procedure
1
Set ND FILTRE switch to “2”.
2
0
01
01
Set the data.
3
6
01
4D
Set the data, and press PAUSE
button.
4
6
9D
Change the data and set the Y
signal level (A) to 630mV.
(Note4) (Fig. 6-1-16.)
5
6
9E
22
Set the data.
6
6
12
80
Set the data.
7
6
12
00
Set the data.
8
Check that the Y signal level (A)
is 630mV.
9
Check that each center of all
color luminance points is set in
each color reproduction frame.
Note4: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75 
.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
9D
00
Set the data.
3
0
01
00
Set the data.
4
Set ND FILTRE switch to
“OFF”.
6-39
HDR-FX1/FX1E
28. Color Reproduction Check
ND OFF HD CINE 
γ
Subject
Color bar chart
(HD color bar standard picture frame)
Measurement Point
NTSC or PAL vectorscope: Video
terminal of AUDIO/VIDEO jack (Note3)
Measuring Instrument
Oscilloscope: COMPONENT
connector
Specified Value
All color luminance points should
settle within each color reproduction
frame (HD CINE 
γ
). (Fig. 6-1-19.)
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note3: When using the vectorscope, disconnect the cable from the
COMPONENT connector.
Note4: NTSC model: HDR-FX1
PAL model: HDR-FX1E
Switch setting:
1)
REC FORMAT (IN/OUT REC menu) .................. HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2)
ND FILTER ...................................................................... OFF
(Page: 6, Address: 9B, Bit4=0, Bit5=0)
3)
STEADY SHOT (CAMERA SET menu) ........................ OFF
4)
FOCUS .................................................................. MANUAL
5)
ZOOM ........................................................................ LEVER
Adjusting method:
Order Page Address Data
Procedure
1
Set ND FILTRE switch to
“OFF”.
2
0
01
01
Set the data.
3
6
8A
04
Set the data.
4
6
9B
Check that bit3 is “1”. (Note5)
5
6
01
4D
Set the data, and press PAUSE
button.
6
6
9D
Change the data and set the Y
signal level (A) to 500mV.
(Note6) (Fig. 6-1-18.)
7
6
9E
22
Set the data.
8
6
12
80
Set the data.
9
6
12
00
Set the data.
10
Check that the Y signal level (A)
is 500mV.
11
Check that each center of all
color luminance points is set in
each color reproduction frame.
Note5: For the bit values, refer to “6-4. SERVICE MODE”, “4-3. 3. Bit
value discrimination”.
Note6: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75 
.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
8A
00
Set the data.
3
6
9D
00
Set the data.
4
0
01
00
Set the data.
Fig. 6-1-18.
For HD CINE 
γ
 mode
Fig. 6-1-19.
H
A
NTSC Burst position
PAL Burst position
6-40
HDR-FX1/FX1E
29. Color Reproduction Check ND 1 HD CINE 
γ
Subject
Color bar chart
(HD color bar standard picture frame)
Measurement Point
NTSC or PAL vectorscope: Video
terminal of AUDIO/VIDEO jack (Note3)
Measuring Instrument
Oscilloscope: COMPONENT
connector
Specified Value
All color luminance points should
settle within each color reproduction
frame (HD CINE 
γ
). (Fig. 6-1-19.)
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note3: When using the vectorscope, disconnect the cable from the
COMPONENT connector.
Switch setting:
1)
REC FORMAT (IN/OUT REC menu ................... HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2)
ND FILTER ........................................................................... 1
(Page: 6, Address: 9B, Bit4=1, Bit5=0)
3)
STEADY SHOT (CAMERA SET menu) ........................ OFF
4)
FOCUS .................................................................. MANUAL
5)
ZOOM ........................................................................ LEVER
Adjusting method:
Order Page Address Data
Procedure
1
Set ND FILTRE switch to “1”.
2
0
01
01
Set the data.
3
6
8A
04
Set the data.
4
6
9B
Check that bit3 is “1”. (Note4)
5
6
01
4D
Set the data, and press PAUSE
button.
6
6
9D
Change the data and set the Y
signal level (A) to 500mV.
(Note5) (Fig. 6-1-18.)
7
6
9E
22
Set the data.
8
6
12
80
Set the data.
9
6
12
00
Set the data.
10
Check that the Y signal level (A)
is 500mV.
11
Check that each center of all
color luminance points is set in
each color reproduction frame.
Note4: For the bit values, refer to “6-4. SERVICE MODE”, “4-3. 3. Bit
value discrimination”.
Note5: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75 
.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
8A
00
Set the data.
3
6
9D
00
Set the data.
4
0
01
00
Set the data.
5
Set ND FILTRE switch to
“OFF”.
30. Color Reproduction Check ND 2 HD CINE 
γ
Subject
Color bar chart
(HD color bar standard picture frame)
Measurement Point
NTSC or PAL vectorscope: Video
terminal of AUDIO/VIDEO jack (Note3)
Measuring Instrument
Oscilloscope: COMPONENT
connector
Specified Value
All color luminance points should
settle within each color reproduction
frame (HD CINE 
γ
). (Fig. 6-1-19.)
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note3: When using the vectorscope, disconnect the cable from the
COMPONENT connector.
Switch setting:
1)
REC FORMAT (IN/OUT REC menu ................... HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2)
ND FILTER ........................................................................... 2
(Page: 6, Address: 9B, Bit4=0, Bit5=1)
3)
STEADY SHOT (CAMERA SET menu) ........................ OFF
4)
FOCUS .................................................................. MANUAL
5)
ZOOM ........................................................................ LEVER
Adjusting method:
Order Page Address Data
Procedure
1
Set ND FILTRE switch to “2”.
2
0
01
01
Set the data.
3
6
8A
04
Set the data.
4
6
9B
Check that bit3 is “1”. (Note4)
5
6
01
4D
Set the data, and press PAUSE
button.
6
6
9D
Change the data and set the Y
signal level (A) to 500mV.
(Note5) (Fig. 6-1-18.)
7
6
9E
22
Set the data.
8
6
12
80
Set the data.
9
6
12
00
Set the data.
10
Check that the Y signal level (A)
is 500mV.
11
Check that each center of all
color luminance points is set in
each color reproduction frame.
Note4: For the bit values, refer to “6-4. SERVICE MODE”, “4-3. 3. Bit
value discrimination”.
Note5: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75 
.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
8A
00
Set the data.
3
6
9D
00
Set the data.
4
0
01
00
Set the data.
5
Set ND FILTRE switch to
“OFF”
6-41
HDR-FX1/FX1E
31. Color Reproduction Check
ND OFF SD STD 
γ
Subject
Color bar chart
(HD color bar standard picture frame)
Measurement Point
NTSC or PAL vectorscope: Video
terminal of AUDIO/VIDEO jack (Note3)
Measuring Instrument
Oscilloscope: COMPONENT
connector
Specified Value
All color luminance points should
settle within each color reproduction
frame (SD STD 
γ
). (Fig. 6-1-21.)
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note3: When using the vectorscope, disconnect the cable from the
COMPONENT connector.
Note4: NTSC model: HDR-FX1
PAL model: HDR-FX1E
Switch setting:
1)
REC FORMAT (IN/OUT REC menu) .............................. DV
(Page: 6, Address: 9B, Bit2=1)
2)
ND FILTER ...................................................................... OFF
(Page: 6, Address: 9B, Bit4=0, Bit5=0)
3)
STEADY SHOT (CAMERA SET menu) ........................ OFF
4)
FOCUS .................................................................. MANUAL
5)
ZOOM ........................................................................ LEVER
Adjusting method:
Order Page Address Data
Procedure
1
Set REC FORMAT to “DV”.
2
Set ND FILTRE switch to
“OFF”.
3
0
01
01
Set the data.
4
6
01
4D
Set the data, and press PAUSE
button.
5
6
9D
Change the data and set the Y
signal level (A) to 90 IRE.
(Note5) (Fig. 6-1-20.)
6
6
9E
22
Set the data.
7
6
12
80
Set the data.
8
6
12
00
Set the data.
9
Check that the Y signal level (A)
is 90 IRE.
10
Check that each center of all
color luminance points is set in
each color reproduction frame.
Note5: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75 
.
90 IRE = 630 mV
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
9D
00
Set the data.
3
0
01
00
Set the data.
Fig. 6-1-20.
For SD STD 
γ
 mode
Fig. 6-1-21.
H
A
NTSC Burst position
PAL Burst position
Page of 86
Display