DOWNLOAD Sony DCR-TRV940 / DCR-TRV940E / DCR-TRV950 / DCR-TRV950E (serv.man4) Service Manual ↓ Size: 999.97 KB | Pages: 78 in PDF or view online for FREE

Model
DCR-TRV940 DCR-TRV940E DCR-TRV950 DCR-TRV950E (serv.man4)
Pages
78
Size
999.97 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-trv940-dcr-trv940e-dcr-trv950-dcr-trv950e-sm4.pdf
Date

Sony DCR-TRV940 / DCR-TRV940E / DCR-TRV950 / DCR-TRV950E (serv.man4) Service Manual ▷ View online

DCR-TRV940/TRV940E/TRV950/TRV950E
6-34
14. Color Reproduction Adjustment
Adjust the color separation matrix coefficient so that proper color
reproduction is produced.
Subject
Color bar chart
(Color reproduction adjustment
frame)
Measurement Point
Video terminal of A/V jack
(75 
 terminated)
Measuring Instrument
Vectorscope, Oscilloscope
Adjustment Page
F
Adjustment Address
38 to 3B
Specified Value
All color luminance points should
settle within each color reproduction
frame.
Note 1:
NTSC model: DCR-TRV940/TRV950
PAL model: DCR-TRV940E/TRV950E
Note 2:
“Color Reproduction Adjustment” is available only once
after the power is turned on. Turn the power off, then on
again if the adjustment is retried.
Note 3:
Check that the data of page: 0, address: 10 is “00”.
Note 4:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Switch setting
1) POWER ................................................................... CAMERA
2) DIGITAL ZOOM (Menu setting) .................................... OFF
3) STEADY SHOT (Menu setting) ..................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
01
3D
Press PAUSE button.
3
6
9D
Change the data and set the
white level (A) of color bar to
the following value.
(Fig. 6-1-15)
NTSC: 90IRE (642.6 mVp-p)
PAL: 630 mVp-p
4
6
01
61
Press PAUSE button.
(Note 5)
5
6
02
Check the data changes to
“01”.
6
Adjust the GAIN and
PHASE of the vectorscope,
and set to the burst lumi-
nance point to the burst
position of color reproduc-
tion frame.
7
Check the each color
luminance point is in each
color reproduction frame.
Note 5:
The adjustment data will be automatically input to page:
F, address: 38 to 3B.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
9D
00
3
0
01
00
Fig. 6-1-15
NTSC model
PAL model
R-Y
B-Y
R
B
G
M
G
Y
E
C
Y
Burst position
R-Y
B-Y
R
B
G
M
G
Y
E
C
Y
Burst position
Fig. 6-1-16
White
A
DCR-TRV940/TRV940E/TRV950/TRV950E
6-35
Pattern A
A4 size (297 x 210 mm)
Black
White
White
15. PSD Sensor Gain Adjustment
Adjust the gain of the PSD sensor for the steady shot.
• Perform the angular velocity sensor sensitivity adjustment only
when replacing the angular velocity sensor or lens block. When
the microprocessor, circuit, etc. malfunctions, do not perform
this adjustment but check operations only.
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
NTSC model: DCR-TRV940/TRV950
PAL model: DCR-TRV940E/TRV950E
Switch setting
1) POWER ................................................................... CAMERA
2) ZOOM ..................................................................... TELE end
3) DIGITAL ZOOM (Menu setting) .................................... OFF
4) STEADY SHOT (Menu setting) ....................................... ON
15-1. PSD Sensor Gain Adjustment (1)
Subject
Pattern A
(1.5 m from the front of lens)
Measurement Point
Video terminal of A/V jack
Measuring Instrument
Oscilloscope (V period)
Adjustment Page
F
Adjustment Address
84
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
F
84
80
Press PAUSE button.
3
6
01
8F
Press PAUSE button.
4
Shoot the pattern A at the
TELE end.
5
Adjust the focus.
6
Measure the falling edge of
waveform, SV1 (msec).
7
6
01
91
Press PAUSE button.
8
Measure the falling edge of
waveform, SV2 (msec).
9
Calculate D
SV
 using
following equations.
(decimal calculation) (Note 1)
NTSC:
D
SV
 = 2.751 
÷
 (SV2 – SV1)
PAL:
D
SV
 = 3.298 
÷
 (SV2 – SV1)
Fig. 6-1-17
Fig. 6-1-18
V
SV1 (msec)
SV2 (msec)
SV2–SV1
Falling edge of
waveform when
data is “8F”
Falling edge of
waveform when
data is “91”
Order Page Address Data
Procedure
10
Calculate D
84
’ using
following equations.
(decimal calculation)
D
84
’ = 128 
×
 D
SV
11
Convert D
84
’ to a hexadeci-
mal number, and obtain D
84
.
(Note 2)
12
F
84
D
84
Press PAUSE button.
Note 1:
Keep a note of D
SV
 value to use at “16. Angular Velocity
Sensor Sensitivity Adjustment”.
Note 2:
Refer to table 6-4-1. “Hexadecimal-decimal conversion
table”
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
0
01
00
3
Check that the steady shot
function operates normally.
DCR-TRV940/TRV940E/TRV950/TRV950E
6-36
15-2. PSD Sensor Gain Adjustment (2)
Subject
Pattern B
(1.5 m from the front of lens)
Measurement Point
Video terminal of A/V jack
Measuring Instrument
Oscilloscope (H period)
Adjustment Page
F
Adjustment Address
85
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
F
85
80
Press PAUSE button.
3
6
01
8F
Press PAUSE button.
4
Shoot the pattern B at the
TELE end.
5
Adjust the focus.
6
Measure the falling edge of
waveform, SH1 (
µ
sec).
7
6
01
91
Press PAUSE button.
8
Measure the falling edge of
waveform, SH2 (
µ
sec).
9
Calculate D
SH
 using
following equations.
(decimal calculation) (Note 1)
NTSC:
D
SH
 = 7.821 
÷
 (SH1 – SH2)
PAL:
D
SH
 = 7.876 
÷
 (SH1 – SH2)
10
Calculate D
85
’ using
following equations.
(decimal calculation)
D
85
’ = 128 
×
 D
SH
11
Convert D
85
’ to a hexadeci-
mal number, and obtain D
85
.
(Note 2)
12
F
85
D
85
Press PAUSE button.
Note 1:
Keep a note of D
SH
 value to use at “16. Angular Velocity
Sensor Sensitivity Adjustment”.
Note 2:
Refer to table 6-4-1. “Hexadecimal-decimal conversion
table”
Pattern B
A4 size (297 x 210 mm)
Blac
k
White
White
Fig. 6-1-19
Fig. 6-1-20
H
SH2 (
µ
sec)
SH1 (
µ
sec)
SH1–SH2
Falling edge of
waveform when
data is “8F”
Falling edge of
waveform when
data is “91”
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
0
01
00
3
Check that the steady shot
function operates normally.
DCR-TRV940/TRV940E/TRV950/TRV950E
6-37
16. Angular Velocity Sensor Sensitivity Adjustment
• Perform the angular velocity sensor sensitivity adjustment only
when replacing the angular velocity sensor or lens block. When
the microprocessor, circuit, etc. malfunctions, do not perform
this adjustment but check operations only.
• Record the sensitivity label of the angular velocity sensor (re-
pair part), including to which side of the board it was attached
to, etc. If it has been attached incorrectly, the image will move
up and down or to the left and right during steady shot opera-
tion. Be sure to take note of this.
Precautions on the Parts Replacement
There are two types of repair parts.
Type A
ENC03MA
Type B
ENC03MB
Replace the broken sensor with a same type sensor. If replace with
other type parts, the image will vibrate up and down or left and
right during hand-shake correction operations. After replacing,
readjust according to the adjusting method after replacement.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
Adjustment Page
F
Adjustment Address
86, 87
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
The sensor sensitivity (SE4001, SE4002 of SE-132 board)
is labeled only on the repair parts.
Switch setting
1) POWER ................................................................... CAMERA
2) ZOOM ..................................................................... TELE end
3) DIGITAL ZOOM (Menu setting) .................................... OFF
4) STEADY SHOT (Menu setting) ....................................... ON
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Read the sensor sensitivity of
SE4001, and it is named
S
4001
.
3
Read the sensor sensitivity of
SE4002, and it is named
S
4002
.
4
Calculate D
86
’, D
87
’ using
following equations.
(decimal calculation) (Note 3)
D
86
’ = D
SV
 
×
 (0.60 
÷
 S
4001
×
 88
D
87
’ = D
SH
 
×
 (0.60 
÷
 S
4002
×
 88
5
Convert D
86
’, D
87
’ to a
hexadecimal number, and
obtain D
86
, D
87
. (Note 4)
6
F
86
D
86
Press PAUSE button.
7
F
87
D
87
Press PAUSE button.
Note 3:
The value that is calculated at “15. PSD Sensor Gain
Adjustment” is used for D
SV
 and D
SH
.
Note 4:
Refer to table 6-4-1. “Hexadecimal-decimal conversion
table”
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
0
01
00
2
Check that the steady shot
function operates normally.
Page of 78
Display

Click on the first or last page to see other DCR-TRV940 / DCR-TRV940E / DCR-TRV950 / DCR-TRV950E (serv.man4) service manuals if exist.