Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-trv940-dcr-trv940e-dcr-trv950-dcr-trv950e-sm4.pdf
Date

Sony DCR-TRV940 / DCR-TRV940E / DCR-TRV950 / DCR-TRV950E (serv.man4) Service Manual ▷ View online

DCR-TRV940/TRV940E/TRV950/TRV950E
6-30
8.
AWB Standard Data Input 
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the white balance reference at 3200K.
Subject
Clear chart
(Color reproduction adjustment
frame)
Adjustment Page
F
Adjustment Address
2A to 2D
Note 1:
“AWB Standard Data Input” is available only once after
the power is turned on. Turn the power off, then on again
if the adjustment is retried.
Note 2:
Check that the data of page: 0, address: 10 is “00”.
Note 3:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Switch setting
1) POWER ................................................................... CAMERA
2) DIGITAL ZOOM (Menu setting) .................................... OFF
3) STEADY SHOT (Menu setting) ..................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
01
11
Press PAUSE button.
3
6
01
0B
Press PAUSE button. (Note 4)
4
6
02
Check the data changes to
“01”.
Note 4:
The adjustment data will be automatically input to page:
F, address: 2A to 2D.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
0
01
00
9.
MAX GAIN Adjustment 
RadarW
RadarW
RadarW
Setting the minimum illumination.
If it is not consistent, the image level required for taking subjects
in low illuminance will not be produced (dark).
Subject
Clear chart
(Color reproduction adjustment
frame)
Adjustment Page
F
Adjustment Address
19
Note 1:
Perform “AWB Standard Data Input” before this adjust-
ment.
Note 2:
Check that the data of page: 0, address: 10 is “00”.
Note 3:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 4:
NTSC model: DCR-TRV940/TRV950
                PAL model: DCR-TRV940E/TRV950E
Switch setting
1) POWER .................................................................. CAMERA
2) DIGITAL ZOOM (Menu setting) .................................... OFF
3) STEADY SHOT (Menu setting) ..................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the following data
2
6
96
32: NTSC model
19: PAL model
3
6
97
00
4
6
01
6F
Press PAUSE button. (Note 5)
5
6
02
Check the data changes to
“01”.
Note 5:
The adjustment data will be automatically input to page:
F, address: 19.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
96
00
2
6
97
00
3
6
01
00
Press PAUSE button.
4
0
01
00
DCR-TRV940/TRV940E/TRV950/TRV950E
6-31
10. F No. & ND Light Quality Standard Data Input
RadarW
RadarW
RadarW
RadarW
RadarW
Correct the lens iris and the dispersion of the ND filter light quan-
tity.
Subject
Clear chart (All white)
(Zoom lens at WIDE end) (Note 2)
Adjustment Page
F
Adjustment Address
1C to 23
Note 1:
Perform “Mechanical Shutter Adjustment” after this ad-
justment.
Note 2:
With the ZOOM at WIDE end, set the distance where
the clear chart is shot with all-white signal.
Note 3:
Check that the data of page: 0, address: 10 is “00”.
Note 4:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Switch setting
1) POWER ................................................................... CAMERA
2) ZOOM .................................................................... WIDE end
3) DIGITAL ZOOM (Menu setting) .................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
30
01
3
6
01
BB
Press PAUSE button. (Note 5)
4
6
02
Check the data changes to “01”.
Note 5:
The adjustment data will be automatically input to page:
F, address: 1C to 23.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
30
00
3
0
01
00
11. LV Standard Data Input 
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the normal coefficient of the light value.
Subject
Clear chart
(Color reproduction adjustment
frame)
Measurement Point
Displayed data of page: 1 (Note 4)
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
1A, 1B
Specified Value
0FE0 to 1020
Note 1:
Perform “AWB Standard Data Input” before this adjust-
ment.
Note 2:
Check that the data of page: 0, address: 10 is “00”.
Note 3:
Check that the data of page: 6, address: 02 is “00”.
                 If not, turn the power of unit OFF/ON.
Note 4:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1 : XX : XX
Displayed data
Switch setting
1) POWER ................................................................... CAMERA
2) DIGITAL ZOOM (Menu setting) .................................... OFF
3) STEADY SHOT (Menu setting) ..................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
30
01
3
6
01
0D
Press PAUSE button. (Note 5)
4
6
02
Check the data changes to
“01”.
5
6
04
1E
6
1
Check that the displayed data
(Note 4) satisfied the
specified value. (Note 6)
Note 5:
The adjustment data will be automatically input to page:
F, address: 1A, 1B.
Note 6:
Retry adjustment if the displayed data did not satisfy the
specified value.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
04
00
3
6
30
00
4
0
01
00
DCR-TRV940/TRV940E/TRV950/TRV950E
6-32
12. Auto White Balance Adjustment 
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility
will be poor.
Subject
Clear chart
(Color reproduction adjustment
frame)
Filter
Filter C14 for color temperature
correction
Adjustment Page
F
Adjustment Address
40 to 43
Note 1:
“Auto White Balance Adjustment” is available only once
after the power is turned on. Turn the power off, then on
again if the adjustment is retried.
Note 2:
Check that the data of page: 0, address: 10 is “00”.
Note 3:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Switch setting
1) POWER .................................................................. CAMERA
2) DIGITAL ZOOM (Menu setting) .................................... OFF
3) STEADY SHOT (Menu setting) ..................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
Place the C14 filter on the
lens.
2
0
01
01
3
6
01
83
Press PAUSE button.
4
6
01
81
Press PAUSE button. (Note 4)
5
6
02
Check the data changes to
“01”.
Note 4:
The adjustment data will be automatically input to page:
F, address: 40 to 43.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
0
01
00
3
Remove the C14 filter on the
lens.
DCR-TRV940/TRV940E/TRV950/TRV950E
6-33
13. Auto White Balance Check 
RadarW
RadarW
RadarW
RadarW
RadarW
Subject
Clear chart
(Color reproduction adjustment
frame)
Filter
Filter C14 for color temperature
correction
ND filter 1.0, 0.4 and 0.1
Measurement Point
Video terminal of Displayed data of
A/V jack
page: 1 (Note 2)
(75 
 terminated)
Measuring Instrument
Vectorscope
Adjusting remote
commander
Specified Value
Fig. 6-1-14
8000 to 8BC0
(A) and (B)
Note 1:
Perform “Auto White Balance Adjustment” before this
adjustment.
Note 2:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1 : XX : XX
Displayed data
Note 3:
Check that the data of page: 0, address: 10 is “00”.
Switch setting
1) POWER ................................................................... CAMERA
2) DIGITAL ZOOM (Menu setting) .................................... OFF
3) STEADY SHOT (Menu setting) ..................................... OFF
Checking method:
Order Page Address Data
Procedure
1
Check that the lens is not
covered with either filter.
  INDOOR luminance point check
2
6
01
0F
Press PAUSE button.
3
Check that the center of the
white luminance point within
the circle shown Fig. 6-1-14.
(A)
4
6
01
00
Press PAUSE button.
  OUTDOOR luminance point check
5
Place the C14 filter on the
lens.
6
6
01
3F
Press PAUSE button.
7
Check that the center of the
white luminance point within
the circle shown Fig. 6-1-14.
(B)
8
6
01
00
Press PAUSE button.
  Data check
9
Remove the C14 filter, and
place the ND filter 1.5 (1.0 +
0.4 + 0.1) on the lens.
10
0
03
06
11
1
Check that the displayed data
(Note 2) satisfied the
specified value.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
0
03
00
3
Remove the ND filter 1.5
(1.0 + 0.4 + 0.1) on the lens.
R-Y
B-Y
2 mm
2 mm
R-Y
B-Y
1 mm
1 mm
3 mm
3 mm
Fig. 6-1-14 (A)
Fig. 6-1-14 (B)
Page of 78