Movie / SECTION 6 ADJUSTMENTS
File
dcr-trv940-dcr-trv940e-dcr-trv950-dcr-trv950e-sm4.pdf
Date

Sony DCR-TRV940 / DCR-TRV940E / DCR-TRV950 / DCR-TRV950E (serv.man4) Service Manual ▷ View online

DCR-TRV940/TRV940E/TRV950/TRV950E
6-38
18. Strobe Light Level Adjustment 
RadarW
RadarW
RadarW
Adjust the strobe light level.
Subject
Flash adjustment box (Note 3)
(50 cm from the front of the lens)
Measurement Point
Adjusting remote commander
Measuring Instrument
Adjustment Page
F
Adjustment Address
8A to 8F
Specified Value
Data of page: F, address: B8 is “00”
Note 1:
Perform “Hall Adjustment”, “Flange Back Adjustment”
and“F No. & ND Light Quality Standard Data Input”
before this adjustment.
Note 2:
Restrict external light to enter the Flash adjustment box
as less as possible.
Note 3:
Refer to “4. Preparing the Flash adjustment box”.
Note 4:
Check that the data of page: 0, address: 10 is “00”.
Note 5:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Switch setting
1) POWER ................................................................... CAMERA
2) DIGITAL ZOOM (Menu setting) .................................... OFF
3) STEADY SHOT (Menu setting) ..................................... OFF
4) Flash .............................................................................. OPEN
(Press the FLASH button to activate the Flash mode, and then
press the PHOTO button.)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
7
05
04
(Note 6)
3
6
30
02
4
6
01
67
Press PAUSE button.
(Note 7)
5
Check the flashing of strobe
light
6
6
02
Check the data changes to
“01”.
7
6
B8
Check the data is “00”.
Note 6:
Press the STOP button on the adjusting remote com-
mander, and set the data.
Note 7:
The adjustment data will be automatically input to page:
F, address: 8A to 8F.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
30
00
3
7
05
00
4
0
01
00
17. Mechanical Shutter Adjustment 
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the close time and loss time every F number of the me-
chanical shutter and the high-speed shutter correction value to
correct the luminous exposure.
Subject
Clear chart (All white)
(Zoom lens at WIDE end) (Note 2)
Measurement Point
Adjusting remote commander
Measuring Instrument
Adjustment Page
F
Adjustment Address
90 to A5
Specified Value
Data of page: 6, address: A8 is “00”
Note 1:
Perform  “HALL Adjustment”,  “Flange Back Adjust-
ment” and “F No. & ND Light Quality Standard Data
Input” before this adjustment.
Note 2:
With the ZOOM at WIDE end, set the distance where
the clear chart is shot with all-white signal.
Note 3:
Check that the data of page: 0, address: 10 is “00”.
Note 4:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Switch setting
1) POWER ................................................................... CAMERA
2) ZOOM .................................................................... WIDE end
3) DIGITAL ZOOM (Menu setting) .................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
30
01
3
6
9C
01
4
6
01
AD
Press PAUSE button. (Note 5)
5
6
02
Check the data changes to “01”.
6
6
A8
Check the data is “00”.
Note 5:
The adjustment data will be automatically input to page:
F, address: 90 to A5.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
30
00
3
6
9C
00
4
0
01
00
DCR-TRV940/TRV940E/TRV950/TRV950E
6-39
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
30
00
3
6
B6
00
4
7
05
00
5
E
00
00
Press PAUSE button.
6
E
01
00
Press PAUSE button.
7
0
01
00
19. Strobe White Balance Adjustment 
RadarW
RadarW
RadarW
Adjust the white balance when the strobe light flashed.
Subject
Flash adjustment box (Note 3)
(50 cm from the front of the lens)
Measurement Point
Video terminal of A/V jack
(75 
 terminated)
Measuring Instrument
Vectorscope
Adjustment Page
F
Adjustment Address
36, 37
Specified Value
Fig. 6-1-21
Note 1:
Perform “Hall Adjustment”, “Flange Back Adjustment”,
“F No. & ND Light Quality Standard Data Input”, “AWB
Adjustment” and “Strobe Light Level Adjustment” be-
fore this adjustment.
Note 2:
Restrict external light to enter the Flash adjustment box
as less as possible.
Note 3:
Refer to “4. Preparing the Flash adjustment box”.
Note 4:
Check that the data of page: 0, address: 10 is “00”.
Switch setting
1) POWER ................................................................... CAMERA
2) DIGITAL ZOOM (Menu setting) .................................... OFF
3) STEADY SHOT (Menu setting) ..................................... OFF
4) Flash .............................................................................. OPEN
(Press the FLASH button to activate the Flash mode, and then
press the PHOTO button.)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
7
05
04
(Note 5)
3
E
00
00
Press PAUSE button.
4
E
01
06
Press PAUSE button.
5
6
B6
41
6
6
B2
01
7
Check that the LED of the
FLASH button is lit.
8
6
B2
00
9
6
30
02
10
6
01
B9
Press PAUSE button.
(Note 6)
11
Check the flashing of strobe
light
12
6
02
Check the data changes to
“01”.
13
6
02
00
14
6
01
E7
Press PAUSE button.
15
Check the flashing of strobe
light
16
6
02
Check the data changes to
“01”.
17
Wait for 3 seconds.
18
Check that the center of the
white luminance point within
the circle shown Fig. 6-1-21.
Note 5:
Press the STOP button on the adjusting remote com-
mander, and set the data.
Note 6:
The adjustment data will be automatically input to page:
F, address: 36, 37.
R-Y
B-Y
2 mm
2 mm
Fig. 6-1-21
DCR-TRV940/TRV940E/TRV950/TRV950E
6-40
20. Hologram AF Output Adjustment 
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust so that the laser output of the hologram AF becomes proper
value.
Subject
Flash adjustment box (Note 3)
(50 cm from the front of the lens)
Measurement Point
Adjusting remote commander
Measuring Instrument
Adjustment Page
F
Adjustment Address
7D to 83
Specified Value 1
10 to FF
Specified Value 2
34 to 4C
Specified Value 3
00 to F0
Specified Value 4
0A to FF
Note 1:
Perform “Hall Adjustment”, “Flange Back Adjustment”,
“F No. & ND Light Quality Standard Data Input” and
“AWB Standard Data Input” before this adjustment.
Note 2:
Restrict external light to enter the Flash adjustment box
as less as possible.
Note 3:
Refer to “4. Preparing the Flash adjustment box”.
Note 4:
Make adjustment with the lens hood removed.
Note 5:
Check that the data of page: 0, address: 10 is “00”.
Note 6:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Switch setting
1) POWER ................................................................... CAMERA
2) DIGITAL ZOOM (Menu setting) .................................... OFF
3) STEADY SHOT (Menu setting) ..................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
30
02
3
6
01
AF
Press PAUSE button.
(Note 7)
4
6
02
Check the data changes to
“01”.
5
F
7D
Check that the data satisfied
the specified value 1.
6
F
82
Check that the data satisfied
the specified value 2.
7
F
7E
Check that the data satisfied
the specified value 3.
8
F
7F
Check that the data satisfied
the specified value 4.
Note 7:
The adjustment data will be automatically input to page:
F, address: 7D to 83.
At this time, check that the laser holograms are all dis-
played on the monitor TV screen.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
30
00
3
0
01
00
DCR-TRV940/TRV940E/TRV950/TRV950E
6-41
AF blind sheet
To adjust the laser 
hologram to the left
To adjust the laser 
hologram to the right
Specification frame
21. Hologram AF Angle Check 
RadarW
RadarW
RadarW
Subject
Dark homogeneous subject (Note 2)
(1 m from the front of the lens)
Measurement Point
Monitor TV
Measuring Instrument
Specified Value
A total of two or more lines in laser
hologram length must be seen in the
specified frame.
The laser hologram lines must be
seen in four directions outside the
specified frame.
Note 1:
Perform “AWB Standard Data Input” before this adjust-
ment.
Note 2:
To observe the laser hologram, use a black box or darken
the ambience.
Switch setting
1) POWER .................................................................. MEMORY
2) DIGITAL ZOOM (Menu setting) .................................... OFF
3) STEADY SHOT (Menu setting) ..................................... OFF
4) FOCUS ........................................................................... MAN
Checking method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
01
3
E
47
0A
Press PAUSE button.
4
0
10
00
5
6
23
04
6
6
5B
B6
7
6
5C
A5
8
6
90
A9
9
6
91
02
10
6
92
67
11
6
93
46
12
6
01
79
Press PAUSE button.
13
6
01
78
Press PAUSE button.
14
Check on the monitor TV
screen that the laser holo-
gram satisfies the specified
value (Fig. 6-1-22). (Note 3)
Note 3:
When the specified value is not satisfied, angle of the
laser hologram can be adjusted by turning the screw as
shown in the Fig. 6-1-23. (in horizontal direction only)
Fig. 6-1-22
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
0
10
01
2
E
47
00
Press PAUSE button.
3
0
10
00
4
6
01
00
Press PAUSE button.
5
6
23
00
6
6
5B
00
7
6
5C
00
8
6
90
00
9
6
91
00
10
6
92
00
11
6
93
00
12
0
01
00
Fig. 6-1-23
Page of 78