DOWNLOAD Sony DCR-TRV40 / DCR-TRV40E / DCR-TRV50 / DCR-TRV50E Service Manual ↓ Size: 14.89 MB | Pages: 127 in PDF or view online for FREE

Model
DCR-TRV40 DCR-TRV40E DCR-TRV50 DCR-TRV50E
Pages
127
Size
14.89 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / LEVEL 3
File
dcr-trv40-dcr-trv40e-dcr-trv50-dcr-trv50e.pdf
Date

Sony DCR-TRV40 / DCR-TRV40E / DCR-TRV50 / DCR-TRV50E Service Manual ▷ View online

5-29
DCR-TRV40/TRV40E/TRV50/TRV50E
12. Auto White Balance & LV Standard Data Input
Adjust the white balance reference at 3200K, and adjust the normal
coefficient of the light value.
Subject
Clear chart
(Color reproduction adjustment frame)
Measurement Point
Display data of page 1 (Note5)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
1A, 1B, 30 to 33
Specified Value
0FF0 to 1010
Note1:
This adjustments should be carried out upon completion of “Color
Reproduction Adjustment”.
Note2:
After the power is turned on, this adjustment can be done only
once.
Note3:
The data of page: 0, address: 10 must be “00”.
Note4:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note5:
Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Display data
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
DIGITAL ZOOM (Menu display) ................................... OFF
4)
STEADY SHOT (Menu display) ..................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
Wait for 2 sec.
3
6
01
11
Set the data, and press PAUSE
button.
4
6
01
0D
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01”. (Note6)
6
0
03
1E
Set the data.
7
1
Check that the display data
(Note5) satisfies the specified
value.
Note6:
The adjustment data will be automatically input to page: F, address:
1A, 1B, 30 to 33.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
0
03
00
Set the data.
3
0
01
00
Set the data.
4
Perform “Auto White Balance
Adjustment”.
5-30
DCR-TRV40/TRV40E/TRV50/TRV50E
13. Auto White Balance Adjustment
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility will
be poor.
Subject
Clear chart
(Color reproduction adjustment frame)
Filter
Filter C14 for color temperature
correction
Measurement Point
Display data of page 1 (Note4)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
34, 35
Specified Value
R ratio: 2B80 to 2C80
B ratio: 5B40 to 5C40
Note1:
This adjustments should be carried out upon completion of “Auto
White Balance & LV Standard Data Input”.
Note2:
After the power is turned on, this adjustment can be done only
once.
Note3:
The data of page: 0, address: 10 must be “00”.
Note4:
Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Display data
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
DIGITAL ZOOM (Menu display) ................................... OFF
4)
STEADY SHOT (Menu display) ..................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
Place the C14 filter for color
temperature correction on the
lens.
2
0
01
01
Set the data.
3
F
44
Write down the data.
4
F
44
2C
Set the data, and press PAUSE
button.
5
F
45
Write down the data.
6
F
45
00
Set the data, and press PAUSE
button.
7
F
46
Write down the data.
8
F
46
5B
Set the data, and press PAUSE
button.
9
F
47
Write down the data.
10
F
47
C0
Set the data, and press PAUSE
button.
11
6
01
83
Set the data, and press PAUSE
button.
12
6
01
81
Set the data, and press PAUSE
button.
13
6
02
Check that the data changes to
“01”. (Note5)
14
6
01
3F
Set the data, and press PAUSE
button.
15
0
03
04
Set the data.
16
1
Check that the display data
(Note4) satisfies the R ratio
specified value.
17
0
03
05
Set the data.
18
1
Check that the display data
(Note4) satisfies the B ratio
specified value.
Note5:
The adjustment data will be automatically input to page: F, address:
34, 35.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
F
44
Set the data that is written down
at step 3, and press PAUSE button.
2
F
45
Set the data that is written down
at step 5, and press PAUSE button.
3
F
46
Set the data that is written down
at step 7, and press PAUSE button.
4
F
47
Set the data that is written down
at step 9, and press PAUSE button.
5
6
01
00
Set the data, and press PAUSE
button.
6
0
03
00
Set the data.
7
0
01
00
Set the data.
5-31
DCR-TRV40/TRV40E/TRV50/TRV50E
14. White Balance Check
Subject
Clear chart
(Color reproduction adjustment frame)
Filter
Filter C14 for color temperature
correction
ND filter 1.0 and 0.4 and 0.1
Measurement Point
Video output terminal
Measuring Instrument
Vectorscope
Specified Value
Fig. 5-1-13. A to B
Note1:
The data of page: 0, address: 10 must be “00”.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
DIGITAL ZOOM (Menu display) ................................... OFF
4)
STEADY SHOT (Menu display) ..................................... OFF
Checking method:
Order Page Address Data
Procedure
Indoor white balance check
1
Check that the lens is not
covered with either filter.
2
6
01
0F
Set the data, and press PAUSE
button.
3
Check that the center of the
white luminance point is within
the circle shown Fig. 5-1-13. A.
4
6
01
00
Set the data, and press PAUSE
button.
Outdoor white balance check
5
Place the C14 filter on the lens.
6
6
01
3F
Set the data, and press PAUSE
button.
7
Check that the center of the
white luminance point is within
the circle shown Fig. 5-1-13. B.
8
Remove the C14 filter.
LV data check
9
Place the ND filter 1.5
(1.0+0.1+0.4) on the lens.
10
6
01
00
Set the data, and press PAUSE
button.
11
0
03
06
Set the data.
12
1
Check that the display data
(Note2) satisfies the specified
value.
  Specified value: 8000 to 8BC0
Note2:
Displayed data of the adjustment remote commander.
1 : XX : XX
Display data
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
0
03
00
Set the data.
R-Y
2mm
B-Y
2mm
R-Y
B-Y
0.5mm
1mm
3mm
3mm
Fig. 5-1-13 (A).
Fig. 5-1-13 (B).
5-32
DCR-TRV40/TRV40E/TRV50/TRV50E
15. Mechanical Shutter Adjustment
Adjustment Page
F
Adjustment Address
76 to 8B
Note:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Input the following data to page: F, addresses: 76 to 8B.
Note:
Press the PAUSE button of the adjustment remote commander each
time to set the data.
3) Select page: 0, address: 01, and set data: 00.
16. Black Defective CCD Adjustment
Detect the black defective positions of the CCD imager.
Subject
Clear chart (All white)
(Approx. 40cm from the front of the lens)
Adjustment Page
1E (Note1)
Adjustment Address
20 to 2F
Note1:
When reading or writing the 1E page data, select page: 0, address:
10, and set data: 01, then select E page. The 1E page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note3:
This adjustment should be carried out upon completion of “Flange
Back Adjustment”.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
6
2C
01
Set the data.
4
6
9C
01
Set the data.
5
6
90
C0
Set the data.
6
6
91
01
Set the data.
7
6
92
00
Set the data.
8
6
93
01
Set the data.
9
6
01
79
Set the data, and press PAUSE
button.
10
Adjust the direction of the
camera so that the whole of the
screen is white.
11
6
01
8D
Set the data, and press PAUSE
button.
12
6
02
Check that the data changes to
“01”. (Note4)
Note4:
The adjustment data will be automatically input to page: 1E,
address: 20 to 2F
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
6
01
00
Set the data, and press PAUSE
button.
3
6
2C
00
Set the data.
4
6
9C
00
Set the data.
5
6
90
00
Set the data.
6
6
91
00
Set the data.
7
6
93
00
Set the data.
8
0
01
00
Set the data.
Address
76
77
78
79
7A
7B
7C
7D
7E
7F
80
81
82
83
84
85
86
87
88
89
8A
8B
NTSC
59
87
43
94
38
81
2F
7B
27
70
47
52
50
48
3B
1D
80
85
83
85
87
80
PAL
49
9D
37
76
2E
75
27
8D
20
76
47
52
4E
47
39
1E
7C
81
84
85
8B
7C
Data
Page of 127
Display

Sony DCR-TRV40 / DCR-TRV40E / DCR-TRV50 / DCR-TRV50E Service Manual ▷ Download