5-21
DCR-TRV40/TRV40E/TRV50/TRV50E
IC 1501
VC-283 board
24 13
37 48
12
1
25
36
1-3.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments (except for
“40.5MHz/54MHz Origin Oscillation Adjustment”), check that the
specified values of “VIDEO SYSTEM ADJUSTMENTS” are
satisfied.
And check that the data of page: 0, address: 10 is “00”. If not, set
data: 00 to this address.
Note:
NTSC model: DCR-TRV40/TRV50
PAL model: DCR-TRV40E/TRV50E
1. 40.5MHz/54MHz Origin Oscillation Adjustment
(VC-283 board)
Set the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color will
become inconsistent.
Subject
Not required
Measurement Point
Pin wf of IC1501
Measuring Instrument
Frequency counter
Adjustment Page
F
Adjustment Address
10
Specified Value
f=27000000 
± 135Hz (NTSC)
f=20250000 
± 101Hz (PAL)
Note:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
F
10
Change the data and set the
frequency (f) to the specified
value.
3
F
10
Press PAUSE button.
4
0
01
00
Set the data.
Fig.5-1-7.
5-22
DCR-TRV40/TRV40E/TRV50/TRV50E
2. HALL Adjustment
For detecting the position of the lens iris and ND filter, adjust AMP
gain and offset.
Subject
Not required
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
13 to 18
Specified Value 1
26 to 2A
Specified Value 2
D6 to DA
Specified Value 3
D6 to DA
Specified Value 4
26 to 2A
Note1:
Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
IRIS display data
ND display data
Note2:
The data of page: 0, address: 10 must be “00”.
Switch setting:
POWER ......................................................................... CAMERA
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
6D
Set the data, and press PAUSE
button.
3
6
02
Check that the data changes to
“01”. (Note3)
4
6
01
00
Set the data, and press PAUSE
button.
Note3:
The adjustment data will be automatically input to page: F, address:
13 to 18.
Checking method:
Order Page Address Data
Procedure
1
0
03
03
Set the data.
2
6
01
01
Set the data, and press PAUSE
button.
3
1
Check that the IRIS display data
(Note1) satisfies the specified
value 1.
4
6
01
03
Set the data, and press PAUSE
button.
5
1
Check that the IRIS display data
(Note1) satisfies the specified
value.2.
6
6
01
69
Set the data, and press PAUSE
button.
7
1
Check that the ND display data
(Note1) satisfies the specified
value 3.
8
6
01
6B
Set the data, and press PAUSE
button.
9
1
Check that the ND display data
(Note1) satisfies the specified
value.4.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
94
00
Set the data.
2
6
95
00
Set the data.
3
6
01
00
Set the data, and press PAUSE
button.
4
0
03
00
Set the data.
5
0
01
00
Set the data.
5-23
DCR-TRV40/TRV40E/TRV50/TRV50E
4. CCD Output 2ch Matching Adjustment (1)
Correct the dispersion of the black level between the left-right
channels of the CCD imager.
Subject
Arbitrary
Adjustment Page
F
Adjustment Address
26, 27
Note1:
This adjustment should be carried out upon completion of the
following adjustments.
“HALL Adjustment”, “MAX GAIN Adjustment”
Note2:
The data of page: 0, address: 10 must be “00”.
Note3:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
F3
Set the data, and press PAUSE
button.
3
6
02
Check that the data changes to
“01”. (Note4)
Note4:
The adjustment data will be automatically input to page: F, address:
26, 27.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
Perform “CCD Output 2ch
Matching Adjustment (2)”.
3. MAX GAIN Adjustment
Setting the minimum illumination.
If it is not consistent, the image level required for taking subjects in
low illuminance will not be produced (dark).
Subject
Clear chart (Approx. 1m from the
front of the lens) (Note1)
Adjustment Page
F
Adjustment Address
19
Note1:
Shoot the clear chart with the zoom WIDE end. And adjust the
direction of the camera so that the chart is located in the center of
the screen.
Note2:
The data of page: 0, address: 10 must be “00”.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
ZOOM .................................................................... WIDE end
4)
DIGITAL ZOOM (Menu display) ................................... OFF
5)
STEADY SHOT (Menu display) ..................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
2C
01
Set the data.
3
6
40
01
Set the data.
4
6
96
Set the following data.
33 (NTSC), 2B (PAL)
5
6
97
00
Set the data.
6
6
01
6F
Set the data, and press PAUSE
button.
7
6
02
Check that the data changes to
“01”. (Note3)
Note3:
The adjustment data will be automatically input to page: F, address:
19.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
2C
00
Set the data.
2
6
40
00
Set the data.
3
6
96
00
Set the data.
4
6
97
00
Set the data.
5
6
01
00
Set the data, and press PAUSE
button.
6
0
01
00
Set the data.
5-24
DCR-TRV40/TRV40E/TRV50/TRV50E
5. CCD Output 2ch Matching Adjustment (2)
Correct the dispersion between the left-right channels of the CCD
imager.
Subject
Clear chart (All white) (Note1)
Adjustment Page
F
Adjustment Address
29 to 2D
Note1:
Shoot the clear chart with the zoom TELE end.
Note2:
This adjustment should be carried out upon completion of the
following adjustments.
CCD Output 2ch Matching adjustment (1)
Note3:
The data of page: 0, address: 10 must be “00”.
Note4:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
ZOOM .................................................................... TELE end
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
F
19
Write down the data.
3
F
19
C0
Set the data.
4
6
2C
01
Set the data.
5
6
40
01
Set the data.
6
6
01
F5
Set the data, and press PAUSE
button.
7
6
02
Check that the data changes to
“00” in about 50 seconds after
pressing PAUSE button.
8
F
19
Set the data that is written down
at step 2, and press PAUE
button.
Note4:
The adjustment data will be automatically input to page: F, address:
29 to 2D
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
2C
00
Set the data.
3
6
40
00
Set the data.
4
0
01
00
Set the data.
6. MR Adjustment
The MR (Magnet resistor) adjustment of the inner focus lens is
carried out automatically. In whichever case, the focus will be
deviated during auto focusing/manual focusing.
Subject
Not required
Measurement Point
Adjustment remote commander
Measuring Instrument
Adjustment Page
F
Adjustment Address
58, 5A to 65
Specified Value1
40 to C0
Specified Value2
03 to 78
Specified Value3
88 to F8
Note1:
Make the lens horizontal and perform this adjustment.
Note2:
Perform this adjustment before “Flange Back Adjustment”.
Note3:
The data of page: 0, address: 10 must be “00”.
Note4:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
BD
Set the data, and press PAUSE
button.
3
6
02
Check that the data changes to
“01”. (Note5)
4
F
5A
Check that the data satisfies the
specified value 1.
5
F
5B
Check that the data satisfies the
specified value 1.
6
F
5C
Check that the data satisfies the
specified value 1.
7
F
5D
Check that the data satisfies the
specified value 1.
8
F
5E
Check that the data satisfies the
specified value 2.
9
F
5F
Check that the data satisfies the
specified value 3.
10
F
60
Check that the data satisfies the
specified value 2.
11
F
61
Check that the data satisfies the
specified value 3.
12
F
62
Check that the data satisfies the
specified value 2.
13
F
63
Check that the data satisfies the
specified value 3.
14
F
64
Check that the data satisfies the
specified value 2.
15
F
65
Check that the data satisfies the
specified value 3.
Note5:
The adjustment data will be automatically input to page: F, address:
58, 5A to 65.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
0
01
00
Set the data.
Page of 127
Display

Click on the first or last page to see other DCR-TRV40 / DCR-TRV40E / DCR-TRV50 / DCR-TRV50E service manuals if exist.