DOWNLOAD Sony DCR-TRV40 / DCR-TRV40E / DCR-TRV50 / DCR-TRV50E Service Manual ↓ Size: 14.89 MB | Pages: 127 in PDF or view online for FREE

Model
DCR-TRV40 DCR-TRV40E DCR-TRV50 DCR-TRV50E
Pages
127
Size
14.89 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / LEVEL 3
File
dcr-trv40-dcr-trv40e-dcr-trv50-dcr-trv50e.pdf
Date

Sony DCR-TRV40 / DCR-TRV40E / DCR-TRV50 / DCR-TRV50E Service Manual ▷ View online

5-5
DCR-TRV40/TRV40E/TRV50/TRV50E
1-1-2.
Preparations
Note1:
For details of how remove the cabinet and boards, refer to “2.
DISASSEMBLY”.
Note2:
When performing only the adjustments, the lens block and boards
need not be disassembled.
Note3:
Before performing the adjustments, check the data of page: 0,
address: 10 is “00”. If not, set data: 00 to this address.
1)
Connect the equipment for adjustments according to Fig. 5-1-
3.
Note4:
As removing the cabinet (R) assembly (removing CN1005 of the
VC-283 board) means removing the lithium 3V power supply
(BT5201 on the CK-115 board), data such as date, time, user-set
menus will be lost. After completing adjustments, reset these data.
But the self-diagnosis data and the data on history of use (total
drum rotation time etc.) will be kept even if the lithium 3V power
supply is removed. (Refer to “5-4.Service Mode” for the self-
diagnosis data and the data on history of use.)
Note5:
Setting the “Forced Camera Power ON” Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 01, and press the PAUSE
button.
The above procedure will enable the camera power to be turned
on with the control switch block (PS-2890, FK-2890) removed.
After completing adjustments, be sure to exit the “Forced Camera
Power ON Mode”.
Note6:
Exiting the “Forced Camera Power ON” Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 00, and press the PAUSE
button.
3) Select page: 0, address: 01, and set data: 00.
Fig.5-1-2.
1.5 m
Front of the lens
Pattern box
5-6
DCR-TRV40/TRV40E/TRV50/TRV50E
Fig.5-1-3.
CN5203
CN5206
CN5202
CN5201
AUDIO/VIDEO jack
Adjustment remote 
commander
LANC jack
Vector scope
AUDIO L (White)
AUDIO R (Red)
VIDEO (Yellow)
Color monitor
Terminated at 75 
EVF block
Must be connected when using the flush unit.
Extension cable (100P)
(J-6082-413-A)
DD-176 board
Must be connected when 
performing the EVF 
system adjustment.
Must be connected.
DCR-TRV50/TRV50E
Need not be connected.
DC IN jack
Battery terminal
VC-283 board
Must be connected when performing the 
video, EVF or LCD system adjustments.
Need not be 
connected.
MA-408 board
CN5903
AC power adaptor 
(8.4Vdc)
Cabinet (R)
CPC-7 jig 
(J-6082-382-A)
CK-115 board
AC-L10,
AC-VQ800 etc.
Front panel block
CN1006
CN1003
CN1009
CN1011
CN1010
CN1901 CN1007
CN1012
CN1005
CN1501
CN1004
CN1301
CN4501
CN4601
CN4602
CN4604
CN4603
5-7
DCR-TRV40/TRV40E/TRV50/TRV50E
1-1-3.
Precaution
1. Setting the Switch
Unless otherwise specified, set the switches as follows and perform adjustments without loading cassette.
1.
POWER switch (PS-2890 block) ........................... CAMERA
2.
NIGHT SHOT switch (Lens block) ................................. OFF
3.
FOCUS switch (KP-2890 block) .......................... MANUAL
4.
BACK LIGHT switch (KP-2890 block) .......................... OFF
5.
COLOR SLOW S/ SUPER NS switch (JK-219 board) ... OFF
6.
DEMO MODE (Menu setting) ........................................ OFF
7.
STEADY SHOT (Menu setting) ...................................... OFF
8.
DIGITAL ZOOM (Menu setting) .................................... OFF
9.
16 : 9 WIDE (Menu setting) ............................................ OFF
10. PROGRAM AE (KP-2890 block) ................................ AUTO
11. PICTURE EFECT (Menu setting) ................................... OFF
12. DIGITAL EFECT (Touch panel setting) .......................... OFF
13. WHITE BALANCE (Menu setting) ............................ AUTO
14. AUTO SHUTTER (Menu setting) ................................... OFF
15. DISPLAY (Menu setting) .................................. V-OUT/LCD
16. DISPLAY (KP-2890 board) .............................................. ON
2. Order of Adjustments
Basically carry out adjustments in the order given.
Fig. 5-1-4.
3. Subjects
1)
Color bar chart (Color reproduction adjustment frame)
When performing adjustments using the color bar chart, adjust
the picture frame as shown in Fig. 5-1-4. (Color reproduction
adjustment frame)
2)
Clear chart (Color reproduction adjustment frame)
Remove the color bar chart from the pattern box and insert a
clear chart in its place. (Do not perform zoom operations during
this time.)
3)
Flange back adjustment chart
Make the chart shown in Fig. 5-1-5 using A0 size (1189mm 
×
841mm) black and white vellum paper.
H
A=B
C=D
A B
B
C
D
A
Enlargement
V
Electronic beam scanning frame
CRT picture frame
B
A
Difference in level
Y
ello
w
Cy
an
Green
White
Magenta
Red
Blue
Y
ello
w
Cy
an
Green
White
Magenta
Red
Blue
Color bar chart (Color reproduction adjustment frame )
Fig. a
(Video output terminal
output waveform)
Fig. b (TV monitor picture)
Adjust the camera zoom and direction to
obtain the output waveform shown in Fig. a
and the TV monitor display shown in Fig. b.
White
Black
841mm
1189mm
Fig. 5-1-5.
Note:
Use matte vellum paper bigger than A0, and make sure the edges of
the black and white paper joined together are not rough.
5-8
DCR-TRV40/TRV40E/TRV50/TRV50E
1-2.
INITIALIZATION OF 8, A, B, C, D, E, F, 1B, 1E,
1F PAGE DATA
Note:
When reading or writing the 1B, 1E or 1F page data, select page: 0,
address: 10, and set data: 01, then select B, E or F page. The 1B, 1E
or 1F page can be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
[Connection of the power supply during the initialization of the
data.]
1)
Connect the regulated power supply and the digital voltmeter
to the battery terminal as shown in Fig. 5-1-6.
2)
Adjust the output voltage of the regulated power supply so that
the digital voltmeter display is 6.0 
± 0.1Vdc.
3)
Turn off the power supply.
4)
Turn on the HOLD switch of the adjusting remote commander.
5)
Turn on the power supply.
6)
Perform the initialization of the data.
Note:
This is normal though the following message is indicated on
the LCD screen.
“FOR InfoLITHIUM BATTERY ONLY”
[Initialization Procedure]
1.
Initialization of A, D page data
2.
Initialization of B, 1B page data
3.
Initialization of 8, C page data
4.
Initialization of E, F, 1E, 1F page data
Fig.5-1-6.
Battery terminal
Regulated power supply
Digital volt meter
Page of 127
Display

Click on the first or last page to see other DCR-TRV40 / DCR-TRV40E / DCR-TRV50 / DCR-TRV50E service manuals if exist.