Sony DCR-TRV40 / DCR-TRV40E / DCR-TRV50 / DCR-TRV50E Service Manual ▷ View online

5-13
DCR-TRV40/TRV40E/TRV50/TRV50E
1-2-3.
INITIALIZATION OF 8, C PAGE DATA
Note:
The data of page: 0, address: 10 must be “00”.
1. Initializing the 8, C Page Data
Note1: If “Initializing the 8, C Page Data” is performed, all data
of the 8 page and C page will be initialized. (It is
impossible to initialize a single page.)
Note2:
If the 8, C page data has been initialized, following adjustments
need to be performed again.
1) Modification of 8, C page data
2) Serial No. input
3) Viewfinder system adjustments
4) LCD system adjustments
5) Servo and RF system adjustments
6) Video system adjustments
Note3:
The power supply voltage must be 6.0 
± 0.1Vdc.
Adjusting page
8
Adjusting Address
00 to A3
Adjusting page
C
Adjusting Address
10 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
3
81
Check that the data is “00”.
4
3
80
0C
Set the data, and press PAUSE
button.
5
3
80
Check that the data changes to
“1C”.
6
Perform “Modification of 8, C
Page Data”.
2. Modification of 8, C Page Data
If the 8, C page data has been initialized, change the data of the
“Fixed data-2” address shown in the following table by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of 8, C Page data
Order Page Address Data
Procedure
1
2
00
29
Set the data.
2
2
01
29
Set the data, and press PAUSE
button.
3. 8 Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C
Page Data”).
Table. 5-1-6.
Address
Remark
Initial value
Address
Remark
Initial value
00 to 18
19
1A to 2E
2F
30 to 3A
3B
3C to 49
4A
4B to 51
52
53 to 59
5A
5B to 79
7A
7B
7C
7D
7E
7F
80
81
82
83
84 to 89
8A
8B
8C
8D
8E
8F
90
91
92
93
99
9A
9B
9C
9D
9E
9F
A0
A1
A2
A3
08
00
46
01
02
00
00
00
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Serial No. input
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
5-14
DCR-TRV40/TRV40E/TRV50/TRV50E
4. C Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C
Page Data”).
Address
Remark
Initial value
Initial value
NTSC PAL
Address
Remark
Initial value
Initial value
NTSC PAL
00 to 0F
10
11
12
13
14 to 15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23 to 24
25
26
27
28
29
2A to 2B
2C
2D to 4E
4F
50
51
52
53
54
55
56
57
58
59
5A
5B
5C
5D
5E
5F
60
61
62
63
EE
00
00
00
E0
2A
2A
32
32
25
3E
3E
DC
99
88
E3
A1
04
20
03
64
CA
5D
5D
AC
80
80
1D
98
98
91
EE
00
00
00
E0
2A
2A
32
32
25
3E
3E
DC
99
88
E3
A1
04
20
03
64
CA
7D
7D
AC
80
80
1D
98
98
91
Switching position adj.
Fixed data-1
CAP FG duty adj.
Fixed data-1
AEQ adj.
Fixed data-1
AEQ adj.
Fixed data-1
AGC center level adj.
PLL fo adj.
APC adj.
LPF fo adj.
Fixed data-1
S VIDEO out Y level adj.
S VIDEO out Cr level adj.
S VIDEO out Cb level adj.
Chroma BPF fo adj.
PLL fo adj.
Fixed data-1
APC adj.
Fixed data-1
Back light adj. (EVF)
VCO adj. (EVF)
Fixed data-2
RGB AMP adj. (EVF)
Fixed data-1
White balance adj. (EVF)
Contrast adj. (EVF)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
VCO adj. (LCD)
V COM adj. (LCD)
64
65
66
67
68
69
6A
6B
6C
6D
6E
6F
70
71
72
73 to 75
76
77 to 79
7A
7B to 80
81
82
83 to 88
89
8A
8B
8C
8D to A9
AA
AB to AB
AC
AD
AE
AF
B0 to C0
C1
C2
C3
C4
C5
C6
C7 to C8
C9
CA
CB
CC
CD
CE
CF to D0
D1
D2
D3
D4
D5
2C
A1
7F
87
3F
2C
A1
7F
87
3F
RGB AMP adj. (LCD)
Fixed data-1
COM AMP adj. (LCD)
White balance adj. (LCD)
Contrast adj. (LCD)
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
5-15
DCR-TRV40/TRV40E/TRV50/TRV50E
Table. 5-1-7.
Address
Remark
Initial value
Initial value
NTSC PAL
D6
D7
D8
D9
DA
DB
DC
DD
DE
DF to E1
E2
E3
E4 to E5
E6
E7
E8
E9 to F3
F4
F5
F6
F7
F8
F9
FA
FB
FC
FD
FE
FF
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Emergency memory address
C page
5-16
DCR-TRV40/TRV40E/TRV50/TRV50E
1-2-4.
INITIALIZATION OF E, F, 1E, 1F PAGE DATA
Note:
When reading or writing the E, F page data, select page: 0, address:
10, and set data: 00.
When reading or writing the 1E or 1F page data, select page: 0,
address: 10, and set data: 01, then select E or F page. The 1E or 1F
page can be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1. Initializing the E, F, 1E, 1F Page Data
Note1: If “Initializing the E, F, 1E, 1F Page Data” is performed,
all data of the E page, F page, 1E page and 1F page will
be initialized. (It is impossible to initialize a single page.)
Note2:
If the E, F, 1E, 1F page data has been initialized, following
adjustments need to be performed again.
1) Modification of E, F, 1E, 1F page data
2) 40.5MHz/54MHz origin osc. adjustment
3) Camera system adjustments
Note3:
The power supply voltage must be 6.0 
± 0.1Vdc.
Note4:
NTSC model: DCR-TRV40/TRV50
PAL model: DCR-TRV40E/TRV50E
Adjusting page
E
Adjusting Address
00 to FF
Adjusting page
F
Adjusting Address
10 to FF
Adjusting page
1E
Adjusting Address
00 to BF
Adjusting page
1F
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
6
01
Set the following data, and press
PAUSE button.
2D (NTSC), 2F (PAL)
4
6
03
01
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01”.
6
Perform “Modification of E, F,
1E, 1F Page Data”.
2. Modification of E, F, 1E, 1F Page Data
If the E, F, 1E, 1F page data has been initialized, change the data of
the “Fixed data-2” address shown in the following table by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
When changing the E, F page data, select page: 0, address: 10,
and set data: 00.
3)
When changing the 1E, 1F page data, select page: 0, address:
10, and set data: 01.
After completing the modification of 1E, 1F page data, reset
the data of this address to “00”.
4)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
5)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of E, F, 1E, 1F Page data
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
2
00
29
Set the data.
3
2
01
29
Set the data, and press PAUSE
button.
4
Perform “40.5MHz/54MHz
Origin Osc. Adjustment” of the
camera system adjustment.
Page of 127