DOWNLOAD Sony DCR-TRV360 / DCR-TRV361 / DCR-TRV460 / DCR-TRV460E / DCR-TRV461E (serv.man4) Service Manual ↓ Size: 1.91 MB | Pages: 66 in PDF or view online for FREE

Model
DCR-TRV360 DCR-TRV361 DCR-TRV460 DCR-TRV460E DCR-TRV461E (serv.man4)
Pages
66
Size
1.91 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-trv360-dcr-trv361-dcr-trv460-dcr-trv460e-dcr-t.pdf
Date

Sony DCR-TRV360 / DCR-TRV361 / DCR-TRV460 / DCR-TRV460E / DCR-TRV461E (serv.man4) Service Manual ▷ View online

DCR-TRV360/TRV361/TRV460/TRV460E/TRV461E
6-6
H
A=B
C=D
A B
B
C
D
A
Enlargement
V
Electronic beam scanning frame
CRT picture frame
B
A
Difference in level
Y
ello
w
Cy
an
Green
White
Magenta
Red
Blue
Y
ello
w
Cy
an
Green
White
Magenta
Red
Blue
Color bar chart (Color reproduction adjustment frame)
Fig. a
(VIDEO terminal of A/V jack
output waveform)
Fig. b (monitor TV picture)
Adjust the camera zoom and direction to
obtain the output waveform shown in Fig. a and
the monitor TV display shown in Fig. b.
1-1-3. Precaution
1.
Setting the Switch
Unless otherwise specified, set the switches as follows and perform adjustments without loading cassette.
1.
POWER switch (SS-5100 block) .......................... CAMERA
2.
FOCUS (MENU setting) ...................................... MANUAL
3.
BACK LIGHT (CF-5100 block) .................................... OFF
4.
PROGRAM AE (MENU setting) ................................ AUTO
5.
NIGHTSHOT PLUS switch (Lens block) ..................... OFF
6.
EXPOSURE (MENU setting) ..................................... AUTO
7.
PICT. EFFECT (MENU setting) .................................... OFF
8.
D. EFFECT (MENU setting) ......................................... OFF
9.
DIGITAL ZOOM (MENU setting) ................................ OFF
10. DEMO MODE (MENU setting) .................................... OFF
11. 16 : 9 WIDE (MENU setting) ........................................ OFF
12. COLOR SLOW S (MENU setting) ................................ OFF
13. DISPLAY (MENU setting) .............................. LCD PANEL
2.
Order of Adjustments
Basically carry out adjustments in the order given.
Fig. 6-1-4
3. Subjects
1)
Color bar chart (Color reproduction adjustment frame)
When performing adjustments using the color bar chart, adjust
the picture frame as shown in Fig. 6-1-4. (Color reproduction
adjustment frame)
2)
Clear chart (Color reproduction adjustment frame)
Remove the color bar chart from the pattern box and insert a
clear chart in its place. (Do not perform zoom operations during
this time)
3) Chart for flange back adjustment
Join together a piece of white A0 size paper (1189mm 
× 841
mm) and a piece of black paper to make the chart shown in
Fig. 6-1-5.
Note:
Use a non-reflecting and non-glazing vellum paper.  The
size must be A0 or larger and the joint between the white
and black paper must not have any undulations.
Fig. 6-1-5
Black
White
841 mm
1189 mm
DCR-TRV360/TRV361/TRV460/TRV460E/TRV461E
6-7
1-2.
INITIALIZATION OF 8, A, B, C, D, E, F, 18, 1B,
1C, 1F PAGE DATA
Note:
If reading/writing data on pages 18, 1B, 1C, 1F, set data:
01 to page: 0, address: 10, and then select pages 8, B, C, F.
By this data setting, the pages 18, 1B, 1C, 1F can be se-
lected.
After the data reading/writing finished, return the data on
page: 0, address: 10 to “00”.
IC4501
VC-345 BOARD (SIDE B)
156 : A
164 : B
1-2-1.
Version Check
Due to the change of IC4501 (mechanism control), there are two
types of versions A and B.
The EEPROM data are different according to respective versions.
Also, the IC4501 version can be checked by a discrimination
method by the model name or by the adjusting remote commander.
Note 1:
Changing the version does not make any changes in sche-
matic diagrams and the rest.
Note 2:
Make it sure to confirm the version after replacing
IC4501.
1.
Discrimination Method by the Model Name of
IC4501 (Mechanism Control)
Fig. 6-1-6
2.
Discrimination Method by Adjusting Remote
Commander
Version check method:
1) Select page: 3, and address: FF.
2) The version of IC4501 can be checked from the displayed data.
Data
Version
11
A
12
B
Data change method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 1C, and input the data in the following table.
Note:
To write in the non-volatile memory (EEPROM), press the
PAUSE button of the adjustment remote commander each
time to set the data.
3) Select page: 0, address: 01, and set data: 00.
Version
A
B
Address
D0
00
42
DCR-TRV360/TRV361/TRV460/TRV460E/TRV461E
6-8
1-2-2.
Initialization of A, B, D, 1B Page Data
Note:
 Check that the data of page: 0, address: 10 is “00”.
1.
Initializing the A, B, D, 1B Page Data
Note 1:
If “Initialization of Pages A, B, D, 1B” is executed, all
data on pages A, B, D, 1B are initialized. (Only an indi-
vidual page cannot be initialized)
Note 2:
If the A, B, D, 1B page data has been initialized, the
following adjustments need to be performed again.
1)  Modification of A, B, D, 1B page data
Note 3:
NTSC model: DCR-TRV360/TRV361/TRV460
PAL model: DCR-TRV460E/TRV461E
Adjustment Page
A
Adjustment Address
10 to FF
Adjustment Page
B
Adjustment Address
00 to FF
Adjustment Page
D
Adjustment Address
10 to FF
Adjustment Page
1B
Adjustment Address
00 to FF
Initializing method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
00
3
7
04
Set the following data
00: NTSC model
01: PAL model
4
7
01
28
5
7
00
01
Press PAUSE button.
6
7
02
Check the data changes to
“01”.
7
Perform “Modification of A,
B, D, 1B Page Data”
2.
Modification of A, B, D, 1B Page Data
If the A, B, D, 1B page data has been initialized, change the data
of the“Fixed data-2” address shown in the following table by
manual input.
Modifying method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note 1:
If copy the data built in the different model, the
camcorder may not operate.
3) When changing the data, press the PAUSE button of the ad-
justment remote commander each time when setting new data
to write the data in the non-volatile memory.
4) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after completing modification A, B, D, 1B page
data:
Order Page Address Data
Procedure
1
0
10
00
2
2
00
29
3
2
01
29
Press PAUSE button.
Note 2:
If the following symptoms occur after completing of
the“Modification A, B, D, 1B page data”, check that the
data of the “Fixed data-2” addresses of A, B, D, 1B page
are same as those of the same model of the same desti-
nation.
1) The power is shut off so that unit cannot operate.
DCR-TRV360/TRV361/TRV460/TRV460E/TRV461E
6-9
4.
B Page Table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the A, B, D, 1B Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of A, B, D, 1B Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to FF
Fixed data-1 (Initialized data)
3.
A Page Table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the A, B, D, 1B Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of A, B, D, 1B Page Data”)
Address
Initial value
Remark
NTSC PAL
10
00
00
Test mode
11 to 1B
Fixed data-1 (Initialized data)
1C
Fixed data-2
1D to 30
Fixed data-1 (Initialized data)
31
Fixed data-2
32 to 50
Fixed data-1 (Initialized data)
51
52
53
Fixed data-2
54
55 to 8F
Fixed data-1 (Initialized data)
90
DB
D2
Touch panel adj.
91
25
1D
92
EA
C6
93
1A
24
94 to CF
Fixed data-1 (Initialized data)
D0
D1
Fixed data-2
D2
D3
Fixed data-1 (Initialized data)
D4
D5
D6
D7
Fixed data-2
D8
D9
DA to FF
Fixed data-1 (Initialized data)
5.
D Page Table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the A, B, D, 1B Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of A, B, D, 1B Page Data”)
Address
Initial value
Remark
NTSC PAL
10 to 13
Fixed data-1 (Initialized data)
14
Fixed data-2
15
Fixed data-1 (Initialized data)
16
Fixed data-2
17 to 19
Fixed data-1 (Initialized data)
1A
Fixed data-2
1B to 27
Fixed data-1 (Initialized data)
28
29
2A
2B
2C
Fixed data-2
2D
2E
2F
30 to 32
Fixed data-1 (Initialized data)
33
Fixed data-2
34 to 56
Fixed data-1 (Initialized data)
57
Fixed data-2
58 to FF
Fixed data-1 (Initialized data)
6.
1B Page Table
Note 1:
If reading/writing data on pages 1B, set data: 01 to page:
0, address: 10, and then select pages B. By this data set-
ting, the pages 1B can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the A, B, D, 1B Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of A, B, D, 1B Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to FF
Fixed data-1 (Initialized data)
Page of 66
Display

Click on the first or last page to see other DCR-TRV360 / DCR-TRV361 / DCR-TRV460 / DCR-TRV460E / DCR-TRV461E (serv.man4) service manuals if exist.