Movie / SECTION 6 ADJUSTMENTS
File
dcr-trv360-dcr-trv361-dcr-trv460-dcr-trv460e-dcr-t.pdf
Date

Sony DCR-TRV360 / DCR-TRV361 / DCR-TRV460 / DCR-TRV460E / DCR-TRV461E (serv.man4) Service Manual ▷ View online

DCR-TRV360/TRV361/TRV460/TRV460E/TRV461E
6-14
18 Page Table
Address
Initial value
Remark
NTSC PAL
98 to 9D
Fixed data-1 (Initialized data)
9E
9F
A0
A1
Fixed data-2
A2
A3
A4 to AF
Fixed data-1 (Initialized data)
B0
Fixed data-2
B1 to B6
Fixed data-1 (Initialized data)
B7
Fixed data-2
B8, B9
Fixed data-1 (Initialized data)
BA
Fixed data-2
BB to FF
Fixed data-1 (Initialized data)
6.
1C Page Table
Note 1:
If reading/writing data on page 1C, set data: 01 to page:
0, address: 10, and then select page C. By this data set-
ting, the page 1C can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, C, 18, 1C Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, C, 18, 1C Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 08
Fixed data-1 (Initialized data)
09
FF
FF
Test mode (Digital8 mode)
0A to B2
Fixed data-1 (Initialized data)
B3
00
00
B4
00
00
B5
00
00
B6
00
00
B7
00
00
B8
80
80
B9
00
00
BA
00
00
BB
00
00
BC
00
00
BD
00
00
SD error rate check (LP)
BE
00
00
BF
00
00
C0
00
00
C1
00
00
C2
00
00
C3
80
80
C4
00
00
C5
00
00
C6
00
00
C7
00
00
C8
00
00
C9 to CF
Fixed data-1 (Initialized data)
D0
Fixed data-2
D1 to FF
Fixed data-1 (Initialized data)
DCR-TRV360/TRV361/TRV460/TRV460E/TRV461E
6-15
2.
Modification of E, F, 1F Page Data
If the E, F, 1F page data has been initialized, change the data of
the “Fixed data-2” address shown in the following table by manual
input.
Modifying method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) If modification of data on pages E, F, set data: 00 to page: 0,
address: 10, and then select pages E, F.
3) If modification of data on page 1F, set data: 01 to page: 0,
address: 10, and then select page F. After the modification of
data finished, return the data on page: 0, address: 10 to “00”.
4) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the
camcorder may not operate.
5) When changing the data, press the PAUSE button of the ad-
justment remote commander each time when setting new data
to write the data in the non-volatile memory.
6) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after completing modification E, F, 1F page data:
Order Page Address Data
Procedure
1
0
10
00
2
2
00
29
3
2
01
29
Press PAUSE button.
1-2-4.
Initialization of E, F, 1F Page Data
Note:
If reading/writing data on page 1F, set data: 01 to page: 0,
address: 10, and then select page F. By this data setting,
the page 1F can be selected.
After the data reading/writing finished, return the data on
page: 0, address: 10 to “00”.
1.
Initializing the E, F, 1F Page Data
Note 1:
If “Initialization of Pages E, F, 1F” is executed, all data
on pages E, F, 1F are initialized. (Only an individual page
cannot be initialized)
Note 2:
If the E, F, 1F page data has been initialized, the follow-
ing adjustments need to be performed again.
1) Modification of E, F, 1F page data
2) “27 MHz Origin Oscillation Adjustment”, “Hi8/Stan-
dard8 Y/C Output Level Setting” and “Hi8/Standard8
AFC f
0
 Adjustment” of the video system adjustment.
3) Camera system adjustments
Note 3:
NTSC model: DCR-TRV360/TRV361/TRV460
PAL model: DCR-TRV460E/TRV461E
Adjustment Page
E
Adjustment Address
00 to FF
Adjustment Page
F
Adjustment Address
10 to FF
Adjustment Page
1F
Adjustment Address
00 to FF
Initializing method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
00
3
6
01
Set the following data, and
press PAUSE button.
2D: NTSC model
2F: PAL model
4
6
03
01
Press PAUSE button.
5
6
02
Check the data changes to
“01”.
6
Perform “Modification of E,
F, 1F Page Data”
3.
E Page Table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the E, F, 1F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of E, F, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 0F
Fixed data-1 (Initialized data)
10
Fixed data-2
11 to 1D
Fixed data-1 (Initialized data)
1E
Fixed data-2
1F, 20
Fixed data-1 (Initialized data)
21
Fixed data-2
22 to B0
Fixed data-1 (Initialized data)
B1
B2
Fixed data-2
B3
B4 to E3
Fixed data-1 (Initialized data)
E4
Fixed data-2
E5 to FF
Fixed data-1 (Initialized data)
DCR-TRV360/TRV361/TRV460/TRV460E/TRV461E
6-16
4. F Page Table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the E, F, 1F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of E, F, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
10
80
80
27 MHz origin osillation adj.
11
Fixed data-1 (Initialized data)
12
4A
4A
Hall adj.
13
56
56
14
11
11
15
20
20
16
02
02
17
E0
E0
18, 19
Fixed data-1 (Initialized data)
1A
00
00
LV standard data input
1B
60
60
1C to 26
Fixed data-1 (Initialized data)
27
Fixed data-2
28, 29
Fixed data-1 (Initialized data)
2A
1B
1B
Auto white balance
2B
00
00
standard data input
2C
07
07
2D
00
00
2E
0E
0E
Auto white balance adj.
2F
00
00
30
0D
0D
31
00
00
32
Fixed data-1 (Initialized data)
33
22
22
Color reproduction adj.
34
Fixed data-1 (Initialized data)
35
27
24
Color reproduction adj.
36 to 39
Fixed data-1 (Initialized data)
3A
00
00
Color reproduction adj.
3B
F1
EF
3C, 3D
Fixed data-1 (Initialized data)
3E
2A
2B
Auto white balance adj.
3F
C0
00
40
59
59
41
00
40
42, 43
Fixed data-1 (Initialized data)
44
28
28
Flange back adj.
45
EC
EC
46
35
35
47
8F
8F
48
13
13
49
B8
B8
4A
00
00
4B
00
00
4C
00
00
Address
Initial value
Remark
NTSC PAL
4D
00
00
Flange back adj.
4E
2B
2B
4F
19
19
50
00
00
51
32
32
52
04
04
53
00
00
54
00
00
55 to 57
Fixed data-1 (Initialized data)
58
59
Fixed data-2
5A
FF
FF
Optical axis adj.
5B to 8D
Fixed data-1 (Initialized data)
8E
8F
Fixed data-2
90
91 to 96
Fixed data-1 (Initialized data)
97
Fixed data-2
98, 99
Fixed data-1 (Initialized data)
9A
Fixed data-2
9B to A3
Fixed data-1 (Initialized data)
A4
Fixed data-2
A5 to E9
Fixed data-1 (Initialized data)
EA
EB
EC
Fixed data-2
ED
EE to FF
Fixed data-1 (Initialized data)
5.
1F Page Table
Note 1:
If reading/writing data on pages 1F, set data: 01 to page:
0, address: 10, and then select pages F. By this data set-
ting, the pages 1F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the E, F, 1F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of E, F, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 52
Fixed data-1 (Initialized data)
53
Fixed data-2
54 to D0
Fixed data-1 (Initialized data)
D1
Fixed data-2
D2 to FF
Fixed data-1 (Initialized data)
DCR-TRV360/TRV361/TRV460/TRV460E/TRV461E
6-17
1-3.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, check that the
specified values of “27 MHz Origin Oscillation Adjustment”, “S
VIDEO OUT Y Level Adjustment” and “S VIDEO OUT C Level
Adjustment” of “VIDEO SYSTEM ADJUSTMENT” are satisfied.
Check that the data of page: 0, address: 10, is “00”.
If not, select page: 0, address: 10, and set data “00”
1. HALL Adjustment 
RadarW
RadarW
RadarW
For detecting the position of lens iris, adjust the hall AMP gain
and offset.
Mode
CAMERA
Subject
Not required
Measurement Point
Displayed data of page: 1 (Note 3)
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
12 to 17
Specified value
87 to 8B during IRIS OPEN
15 to 19 during IRIS CLOSE
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 3:
The right two digits of the page: 1 displayed data of the
adjusting remote commander.
1:00:XX
Displayed data
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
94
89
3
6
95
17
4
6
01
6D
Press PAUSE button. (Note 4)
5
6
02
Check the data changes to
“01”.
6
6
01
00
Press PAUSE button.
Note 4:
The adjustment data will be automatically input to page:
F, address: 12 to 17.
Checking method:
Order Page Address Data
Procedure
1
0
03
03
2
6
01
01
Press PAUSE button.
3
1
Check that the displayed data
(Note 3) during IRIS OPEN
satisfied the specified value.
4
6
01
03
Press PAUSE button.
5
1
Check that the displayed data
(Note 3) during IRIS CLOSE
satisfied the specified value.
Processing after completing adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
94
00
3
6
95
00
4
0
03
00
5
0
01
00
Page of 66
Display