DOWNLOAD Sony DCR-TRV360 / DCR-TRV361 / DCR-TRV460 / DCR-TRV460E / DCR-TRV461E (serv.man4) Service Manual ↓ Size: 1.91 MB | Pages: 66 in PDF or view online for FREE

Model
DCR-TRV360 DCR-TRV361 DCR-TRV460 DCR-TRV460E DCR-TRV461E (serv.man4)
Pages
66
Size
1.91 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-trv360-dcr-trv361-dcr-trv460-dcr-trv460e-dcr-t.pdf
Date

Sony DCR-TRV360 / DCR-TRV361 / DCR-TRV460 / DCR-TRV460E / DCR-TRV461E (serv.man4) Service Manual ▷ View online

DCR-TRV360/TRV361/TRV460/TRV460E/TRV461E
6-10
2.
Modification of 8, C, 18, 1C Page Data
If the 8, C, 18, 1C page data has been initialized, change the data
of the “Fixed data-2” address shown in the following table by
manual input.
Modifying method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) If modification of data on pages 8, C, set data: 00 to page: 0,
address: 10, and then select pages 8, C.
3) If modification of data on pages 18, 1C, set data: 01 to page:
0, address: 10, and then select pages 8, C. After the modifica-
tion of data finished, return the data on page: 0, address: 10 to
“00”.
4) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the
camcorder may not operate.
5) When changing the data, press the PAUSE button of the ad-
justment remote commander each time when setting new data
to write the data in the non-volatile memory.
6) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after completing modification 8, C, 18, 1C page
data:
Order Page Address Data
Procedure
1
0
10
00
2
2
00
29
3
2
01
29
Press PAUSE button.
1-2-3.
Initialization of 8, C, 18, 1C Page Data
Note:
If reading/writing data on pages 18, 1C, set data: 01 to
page: 0, address: 10, and then select pages 8, C. By this
data setting, the pages 18, 1C can be selected.
After the data reading/writing finished, return the data on
page: 0, address: 10 to “00”.
1.
Initializing the 8, C, 18, 1C Page Data
Note 1:
If “Initialization of Pages 8, C, 18, 1C” is executed, all
data on pages 8, C, 18, 1C are initialized. (Only an indi-
vidual page cannot be initialized)
Note 2:
If the 8, C, 18, 1C page data has been initialized, the
following adjustments need to be performed again.
1) Modification of 8, C, 18, 1C page data
2) Electronic viewfinder system adjustments
3) LCD system adjustments
4) Node unique ID No. input
5) Servo, RF system adjustments
6) “S VIDEO OUT Y Level Adjustment” and “S VIDEO
OUT C Level Adjustment” of the video system ad-
justments
7) Audio system adjustments
Adjustment Page
8
Adjustment Address
00 to FF
Adjustment Page
C
Adjustment Address
10 to FF
Adjustment Page
18
Adjustment Address
00 to FF
Adjustment Page
1C
Adjustment Address
00 to FF
Initializing method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
00
3
3
81
10
4
3
80
0C
Press PAUSE button.
5
3
80
Check the data changes to
“1C”.
6
Perform “Modification of 8,
C, 18, 1C Page Data”
DCR-TRV360/TRV361/TRV460/TRV460E/TRV461E
6-11
3.
8 Page Table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, C, 18, 1C Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, C, 18, 1C Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 29
Fixed data-1 (Initialized data)
2A
Fixed data-2
2B to 79
Fixed data-1 (Initialized data)
7A
Fixed data-2
7B to AB
Fixed data-1 (Initialized data)
AC
Fixed data-2
AD to BD
Fixed data-1 (Initialized data)
BE
Fixed data-2
BF to C2
Fixed data-1 (Initialized data)
C3
C4
Fixed data-2
C5
C6, C7
Fixed data-1 (Initialized data)
C8
C9
CA
Fixed data-2
CB
CC
Fixed data-1 (Initialized data)
CD
Fixed data-2
CE to D5
Fixed data-1 (Initialized data)
D6
D7
Fixed data-2
D8 to FF
Fixed data-1 (Initialized data)
DCR-TRV360/TRV361/TRV460/TRV460E/TRV461E
6-12
Address
Initial value
Remark
NTSC PAL
AE to D2
Fixed data-1 (Initialized data)
D3
Fixed data-2
D4
Fixed data-1 (Initialized data)
D5
D6
Fixed data-2
D7
Fixed data-1 (Initialized data)
D8
D9
DA
Fixed data-2
DB
DC to DE
Fixed data-1 (Initialized data)
DF
Fixed data-2
E0
08
08
E1
00
00
E2
46
46
E3
01
01
Node unique ID No. input
E4
02
02
E5
00
00
E6
00
00
E7
00
00
E8 to F3
Fixed data-1 (Initialized data)
F4
00
00
F5
00
00
F6
00
00
F7
00
00
F8
00
00
F9
00
00
Emergency memory
FA
00
00
FB
00
00
FC
00
00
FD
00
00
FE
00
00
FF
00
00
4.
C Page Table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, C, 18, 1C Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, C, 18, 1C Page Data”)
Address
Initial value
Remark
NTSC PAL
10
EE
EE
Digital8 switching position adj.
11
00
00
12
00
00
13
00
00
14, 15
Fixed data-1 (Initialized data)
16
E0
E0
CAP FG duty adj.
17
E0
E0
REEL FG adj.
18 to 24
Fixed data-1 (Initialized data)
25
80
80
S VIDEO OUT Y level adj.
26
70
70
S VIDEO OUT C level adj.
27
50
50
28 to 2E
Fixed data-1 (Initialized data)
2F
0E
0E
REEL FG adj.
30, 31
Fixed data-1 (Initialized data)
32
0A
0A
Hi8/Standard switching position adj.
33
00
00
34
30
30
Hi8/Standard8 AFC f
0
 adj.
35
A0
A0
Hi8/Standard8 Y/C output level setting
36
AA
AA
37
Fixed data-1 (Initialized data)
38
A6
A6
Hi8/Standard8 AFM 1.5 MHz deviation adj.
39
94
94
Hi8/Standard8 AFM 1.7 MHz deviation adj.
3A
80
80
Hi8/Standard8 AFM BPF f
0
 adj.
3B to 4E
Fixed data-1 (Initialized data)
4F
Fixed data-2
50
85
85
LCD level adj. (VCO adj.)
51
8F
8F
52
90
90
LCD V-COM adj.
53
A2
A2
LCD level adj. (RGB AMP adj.)
54, 55
Fixed data-1 (Initialized data)
56
7A
7A
LCD White balance adj.
57
5F
5F
58
2E
2E
LCD level adj. (Contrast adj.)
59
5A
Fixed data-2
5B
C0
C0
LCD level adj. (PSIG black adj.)
5C to 65
Fixed data-1 (Initialized data)
66
Fixed data-2
67 to 71
Fixed data-1 (Initialized data)
72
Fixed data-2
73, 74
Fixed data-1 (Initialized data)
75
Fixed data-2
76 to AC
Fixed data-1 (Initialized data)
AD
Fixed data-2
DCR-TRV360/TRV361/TRV460/TRV460E/TRV461E
6-13
Address
Initial value
Remark
NTSC PAL
59
Fixed data-2
5A, 5B
Fixed data-1 (Initialized data)
5C
5D
Fixed data-2
5E
5F
Fixed data-1 (Initialized data)
60
Fixed data-2
61, 62
Fixed data-1 (Initialized data)
63
Fixed data-2
64 to 67
Fixed data-1 (Initialized data)
68
Fixed data-2
69 to 6D
Fixed data-1 (Initialized data)
6E
6F
Fixed data-2
70 to 74
Fixed data-1 (Initialized data)
75
Fixed data-2
76
Fixed data-1 (Initialized data)
77
78
Fixed data-2
79
Fixed data-1 (Initialized data)
7A
7B
Fixed data-2
7C
7D
Fixed data-1 (Initialized data)
7E
Fixed data-2
7F
Fixed data-1 (Initialized data)
80
81
Fixed data-2
82
83, 84
Fixed data-1 (Initialized data)
85
86
Fixed data-2
87
Fixed data-1 (Initialized data)
88
Fixed data-2
89
Fixed data-1 (Initialized data)
8A
8B
8C
8D
Fixed data-2
8E
8F
90
Fixed data-1 (Initialized data)
91
Fixed data-2
92
Fixed data-1 (Initialized data)
93
Fixed data-2
94
Fixed data-1 (Initialized data)
95
Fixed data-2
96
Fixed data-1 (Initialized data)
97
Fixed data-2
5.
18 Page Table
Note 1:
If reading/writing data on page 18, set data: 01 to page:
0, address: 10, and then select page 8. By this data set-
ting, the page 18 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, C, 18, 1C Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, C, 18, 1C Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 11
Fixed data-1 (Initialized data)
12
00
00
Test mode (Hi8/Standard8 mode)
13
14
Fixed data-2
15
Fixed data-1 (Initialized data)
16
Fixed data-2
17 to 1B
Fixed data-1 (Initialized data)
1C
Fixed data-2
1D, 1E
Fixed data-1 (Initialized data)
1F
20
Fixed data-2
21
Fixed data-1 (Initialized data)
22
23
24
Fixed data-2
25
26
27
Fixed data-1 (Initialized data)
28
29
Fixed data-2
2A, 2B
Fixed data-1 (Initialized data)
2C
2D
Fixed data-2
2E, 2F
Fixed data-1 (Initialized data)
30
Fixed data-2
31, 32
Fixed data-1 (Initialized data)
33
Fixed data-2
34
Fixed data-1 (Initialized data)
35
Fixed data-2
36
Fixed data-1 (Initialized data)
37
Fixed data-2
38 to 3A
Fixed data-1 (Initialized data)
3B
Fixed data-2
3C to 3E
Fixed data-1 (Initialized data)
3F
Fixed data-2
40 to 51
Fixed data-1 (Initialized data)
52
Fixed data-2
53
Fixed data-1 (Initialized data)
54
55
Fixed data-2
56 to 58
Fixed data-1 (Initialized data)
Page of 66