DCR-TRV360/TRV361/TRV460/TRV460E/TRV461E
6-18
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
48
01
3
6
01
13
Press PAUSE button.
4
6
01
27
Press PAUSE button. (Note 7)
5
6
02
Check the data changes to
“01”.
Note 7:
The adjustment data will be automatically input to page:
F, address: 44 to 54.
Processing after completing adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
01
25
Press PAUSE button.
3
6
01
00
Press PAUSE button.
4
6
48
00
5
0
01
00
6
Perform “Flange Back
Check”.
2. Flange Back Adjustment 
RadarW
RadarW
RadarW
(Using the Minipattern Box)
The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated dur-
ing auto focusing/manual focusing.
Mode
CAMERA
Subject
Siemens star chart with ND filter for
minipattern box (Note 1)
Measurement Point
Check operation on monitor TV
Measuring Instrument
Adjustment Page
F
Adjustment Address
44 to 54
Note 1:
Dark Siemens star chart.
Note 2:
Check that the data of page: 0, address: 10 is “00”.
Note 3:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 4:
Perform the adjustment with the camcorder in horizon-
tal state.
Note 5:
Perform “HALL Adjustment” before this adjustment.
Switch setting:
1) NIGHTSHOT PLUS ........................................................ OFF
2) DISPLAY (Menu setting) ................................. LCD PANEL
Preparations before adjustments:
1) The minipattern box is installed as shown in the following fig-
ure.
Note 6: 
The attachment lenses are not used.
2) Install the minipattern box so that the distance between it and
the front of lens of camcorder is less than 3 cm.
3) Make the height of minipattern box and the camera equal.
4) Check the output voltage of the regulated power supply is the
specified voltage 
± 0.01 Vdc.
5) Check that the center of Siemens star chart meets the center of
shot image screen with the zoom lens at TELE end and WIDE
end respectively.
Specified voltage: The specified voltage varies according to the
minipattern box, so adjust the power supply
output voltage to the specified voltage written
on the sheet which is supplied with the
minipattern box.
Minipattern box
Below 3 cm
Camcorder
Camera 
table
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Need not connected
Regulated power supply
Output voltage : Specified voltage 
±
0.01 Vdc
Output current : more than 3.5 A
Fig. 6-1-7
DCR-TRV360/TRV361/TRV460/TRV460E/TRV461E
6-19
3-2. Flange Back Adjustment (2) 
RadarW
RadarW
RadarW
RadarW
RadarW
Perform this adjustment after performing “Flange Back Adjust-
ment (1)”.
Mode
CAMERA
Subject
Subject more than 500 m away
(Subject with clear contrast such as
buildings, etc.)
Measurement Point
Check operation on monitor TV
Measuring Instrument
Adjustment Page
F
Adjustment Address
44 to 54
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Switch setting:
1) NIGHTSHOT PLUS ........................................................ OFF
2) DISPLAY (Menu setting) .................................. LCD PANEL
Preparations before adjustments:
1) Set the zoom lens to the TELE end and expose a subject that is
more than 500 m away.
(subjects with clear contrast such as building, etc.)
(Nearby subjects less than 500 m away should not be in the
screen)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
48
01
3
6
01
13
Press PAUSE button.
4
Place ND filter on the lens so
that the optimum image is
obtain.
5
6
01
29
Press PAUSE button. (Note 3)
6
6
02
Check the data changes to
“01”.
Note 3:
The adjustment data will be automatically input to page:
F, address: 44 to 54.
Processing after completing adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
01
25
Press PAUSE button.
3
6
01
00
Press PAUSE button.
4
6
48
00
5
0
01
00
6
Perform “Flange Back
Check”.
3. Flange Back Adjustment
(Using the Flange Back Adjustment Chart and
Subject More than 500 m Away)
The inner focus lens flange back adjustment is carried out auto-
matically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
3-1. Flange Back Adjustment (1) 
RadarW
RadarW
RadarW
Mode
CAMERA
Subject
Flange back adjustment chart
(2.0 m from the front of lens)
(Luminance: 300 to 400 lux)
Measurement Point
Check operation on monitor TV
Measuring Instrument
Adjustment Page
F
Adjustment Address
44 to 54
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 3:
Perform the adjustment with the camcorder in horizon-
tal state.
Note 4:
Perform “HALL Adjustment” before this adjustment.
Switch setting:
1) NIGHTSHOT PLUS ........................................................ OFF
2) DISPLAY (Menu setting) .................................. LCD PANEL
Preparations before adjustments:
1) Place the Flange back adjustment chart 2.0 m from the front
of the lens.
2) Check that the center of Flange back adjustment chart meets
the center of shot image screen with the zoom lens at TELE
end and WIDE end respectively.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
48
01
3
6
01
13
Press PAUSE button.
4
6
01
15
Press PAUSE button. (Note 5)
5
6
02
Check the data changes to
“01”.
Note 5:
The adjustment data will be automatically input to page:
F, address: 44 to 54.
Processing after completing adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
01
25
Press PAUSE button.
3
6
01
00
Press PAUSE button.
4
6
48
00
5
0
01
00
6
Perform “Flange Back
Adjustment (2)”.
DCR-TRV360/TRV361/TRV460/TRV460E/TRV461E
6-20
4. Flange Back Check
Mode
CAMERA
Subject
Siemens star
(2.0 m from the front of the lens)
(Luminance: approx. 200 lux)
Measurement Point
Check operation on monitor TV
Measuring Instrument
Specified value
Focused at the TELE end and WIDE
end
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Switch setting:
1) NIGHTSHOT PLUS ........................................................ OFF
2) DISPLAY (Menu setting) .................................. LCD PANEL
Note 2:
When the auto focus is ON, the lens can be checked if it
is focused or not by observing the data on the page: 1 of
the adjusting remote commander.
1 : 00 : XX
Odd: Focused
Even: Unfocused
Checking method:
Order Page Address Data
Procedure
1
Place the Siemens star 2.0 m
from the front of the lens.
2
To open the IRIS, decrease
the luminous intensity to the
Siemens star up to a point
before noise appear on the
image.
3
6
40
01
4
6
41
01
5
Shoot the Siemens star with
the zoom TELE end.
6
Turn on the auto focus.
7
0
03
0F
8
1
Check that the lens is
focused. (Note 2)
9
6
21
10
10
Shoot the Siemens star with
the zoom WIDE end.
11
Observe the TV monitor and
check that the lens is
focused.
Processing after completing adjustment:
Order Page Address Data
Procedure
1
6
21
00
2
6
40
00
3
6
41
00
4
0
03
00
DCR-TRV360/TRV361/TRV460/TRV460E/TRV461E
6-21
5. Optical Axis Adjustment
Correct a deviation of optical axis between the lens and the CCD
imager.
If deviated, the screen center will be shifted when the lens is
zoomed from TELE end to WIDE end.
Subject
Siemens Star
Measurement Point
Check operation on monitor TV
Measuring Instrument
Adjustment Page
F
Adjustment Address
5A
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
“Flange Back Adjustment” must be already finished.
Switch setting:
1) DIGITAL ZOOM (Menu setting) .................................... OFF
2) STEADYSHOT (Menu setting) ...................................... OFF
3) DISPLAY (Menu setting) .................................. LCD PANEL
Preparation for adjustment:
1) Play a monoscope portion of the System Check tape (WR5-
5NSP (NTSC) or WR5-5CSP (PAL)).
2) Stick the optical axis deviation specification frame to the moni-
tor screen so that the center of monoscope coincides with the
center of specification frame.
3) Select the CAMERA mode.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: F, address: 5A, and set data: 00, then press the
PAUSE button on the adjusting remote commander.
3) Place the Siemens Star at 2 m position away from the lens.
4) Shoot the Siemens Star with the zoom at TELE end.
5) Change the lens direction so that the center of Siemens Star
coincides with the center of optical axis deviation specifica-
tion frame.
6) Shoot the Siemens Star with the zoom at WIDE end.
7) Check on the monitor TV which area the center of Siemens
Star exists of the optical axis deviation specification frame.
At this time, measure the amount of deviation “L1” (distance
from the center of Siemens Star to the center of optical axis
deviation specification frame).
8) From the following table, read correction data according to
the area.
0
180
90
67.5
22.5
337.5
292.5
247.5
202.5
157.5
112.5
8
4
5
7
1
6
2
3
270
Fig. 6-1-8
Area
1
2
3
4
5
6
7
8
Deviation Phase
22.6
° to 67.5°
67.6
° to 112.5°
112.6
° to 157.5°
157.6
° to 202.5°
202.6
° to 247.5°
247.6
° to 292.5°
292.6
° to 337.5°
337.6
° to 22.5°
Correction Data
01
02
03
04
05
06
07
08
9) Select page: F, address: 5A, and set correction data, then press
the PAUSE button on the adjusting remote commander.
10) Shoot the Siemens Star with the zoom at TELE end.
11) Change the lens direction so that the center of Siemens Star
coincides with the center of optical axis deviation specifica-
tion frame.
12) Shoot the Siemens Star with the zoom at WIDE end.
13) Measure the amount of deviation “L2” (distance from the cen-
ter of Siemens Star to the center of optical axis deviation speci-
fication frame).
14) Compare L1 and L2, and make sure that the L2 is smaller than
L1.
If large, select page: F, address: 5A, and set data: 00, then
press the PAUSE button on the adjusting remote commander.
Processing after completion of adjustment:
1) Select page: 0, address: 01, and set data: 00.